OVERALL LOSS
LARGEST EVENT
C
View Details softkey
Item
The end-to-end loss of the cabling, excluding the OTDR connection and the end event. The
loss does not include launch and receive fibers if launch and receive fiber compensation
are enabled.
Note that OVERALL LOSS does not include the losses of the first and last connectors in the
cabling if you did not use launch and receive fiber compensation.
If the test ran at two wavelengths, the highest loss of the two wavelengths is reported.
The largest loss event on the cabling.
Lets you see the overall results and event results along with the test limits. These results
include values measured by the selected test limit but not shown on other OTDR screens,
such as segment attenuation coefficients, optical return loss, and reflectance. Use the
softkeys on the OTDR DETAILS screens to switch between overall results details and event
details.
See “OTDR Details Screens” on page 3-37 or press
Table 3-2. OTDR Summary Screen Features (cont.)
Description
H
Looking at OTDR Test Results
for information about OTDR details.
Using the OTDR
3-21