CV500II101 Omron, CV500II101 Datasheet - Page 56

no-image

CV500II101

Manufacturer Part Number
CV500II101
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500II101

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
46
Operations
MONTR
Inputs for remaining
four items.
CLR
Specify the remaining 4 items for monitoring. Up to 8 items can be spe-
cified.
To increment or decrement the word and bit address on the first line,
press the Up or Down Key. To specify a different address in the same
area for the item on the first line, you only need to input the address and
not the area abbreviation.
Press the Monitor Key to scroll one line. If more than four items are
being monitored, the bottom line will move to a memory buffer and the
next one held in memory will be moved onto the display.
Press the Clear Key to delete the item on the first line.
Section 4-4

Related parts for CV500II101