3G3JX-A2004 Omron, 3G3JX-A2004 Datasheet

AC Motor Drive

3G3JX-A2004

Manufacturer Part Number
3G3JX-A2004
Description
AC Motor Drive
Manufacturer
Omron
Datasheet

Specifications of 3G3JX-A2004

Supply Voltage Range
200V To 240V
No. Of Phases
Three
Power Rating
400W
Output Voltage Max
240V
Output Frequency Max
400Hz
Mounting Type
DIN Rail
Output Voltage Min
200V
External Height
155mm
Frequency Range
0.5 To 400Hz
Rohs Compliant
Yes
External Depth
109.5mm
External Width
80mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
New AC Drives Family Delivers Excellent
Performance and Value
AC Drives Reduce Motor Wear and Improve
Energy Efficiency to Reduce Your Operating Costs
Space- and energy-saving features
Three models address simple to complex needs
Easy-to-apply advanced functions
High torque at low frequencies

Related parts for 3G3JX-A2004

3G3JX-A2004 Summary of contents

Page 1

New AC Drives Family Delivers Excellent Performance and Value AC Drives Reduce Motor Wear and Improve Energy Efficiency to Reduce Your Operating Costs Three models address simple to complex needs Space- and energy-saving features Easy-to-apply advanced functions High torque at ...

Page 2

Simple, Compact Inverters JX SYSDRIVE Nomenclature and Functions ■ Inverter Nomenclature and Functions 8k8k8k8 Note 1. Connect the communications cable after opening the cover of the communications connector. Remove the front cover to switch communications. 2. The cover of the ...

Page 3

Part Names and Descriptions of the Digital Operator Data display RUN command LED indicator Operation keys Name POWER LED indicator ALARM LED indicator RUN (during RUN) LED indicator PROGRAM LED indicator 8k8k8k8 Data display Data display LED indicator Volume ...

Page 4

Using Digital Operator 1. Setting the maximum output frequency Power ON (1) 0.0 or the value previously monitored is displayed. 0.0 Press key. (2) Function code appears. Ddk0k0k1 Press until A --- appears. (3) A --- appears. ak-k-k- Press key. ...

Page 5

Running the motor (by potentiometer) Power ON (1) 0.0 or the value previously monitored is displayed. 0.0 Press key and turn the potentiometer clockwise. (2) The motor runs at the fre- quency set by the potentiom- D5k0k0 eter. Press ...

Page 6

... Self-cooling At short-time deceleration *3 Approx. 50% At capacitor Braking torque feedback DC injection Injection braking frequency/time, braking force variable, frequency control available braking ●1/3-phase 200-V Class Item Model name (3G3JX-) kW 0.2 Applicable motor capacity *1 HP 1/4 200 V 0.4 Rated output capacity (kVA) 240 V 0.5 1/3-phase 200 V − ...

Page 7

Common Specifications Item Enclosure rating *4 Semi-closed (IP20) Control method Phase-to-phase sinusoidal modulation PWM *5 Output frequency range 0.5 to 400 Hz Digital command: ±0.01% of the max. frequency Frequency precision *6 Analog command:±0.4% of the max. frequency (25°C ...

Page 8

Terminal Block Specifications ●Terminal Block Position Main circuit terminal block (input side) Communications connector Relay output terminal block Control circuit terminal block Main circuit terminal block (output side) Note: This illustration shows the terminal block with the front cover ...

Page 9

Circuit Terminals Specifications Analog Analog output Terminal Terminal name and function symbol External power supply terminal for input signal (input) ...At sink logic PSC Internal power supply output ...

Page 10

... Dimensions 3G3JX-A2002 3G3JX-A2004 3G3JX-A2007 5 3G3JX-AE002 6 3G3JX-AE004 3G3JX-A4004 3G3JX-AE007 Simple, Compact Inverters SYSDRIVE 80 67 ±0.2 143 ±0.2 155 5 1.9 110 98 ±0.3 176 ±0.3 189 5 1.9 JX Series (Unit: mm) 2 Dimensions (mm) Rated Model voltage 3G3JX A2002 95.5 13 3phase A2004 109.5 27 200 V AC A2007 132.5 ...

Page 11

... Simple, Compact Inverters SYSDRIVE 6 55 157 Series ...

Page 12

Standard Connection Diagram 3-phase 200 V AC 1/3-phase 200 3-phase 400 V AC Multi-function input 1 Multi-function input 2 Multi-function input 3 Multi-function input 4 Multi-function input 5 Sequence input common Frequency reference power supply Frequency Frequency ...

Page 13

Protective and Diagnostic Functions ●Error Code List Display on Digital Operator Name ek_k0k1 ek_k0k2 Overcurrent trip ek_k0k3 ek_k0k4 ek_k0k5 Overload trip Overvoltage trip ek_k0k7 EEPROM error ek_k0k8 Undervoltage trip ek_k0k9 CPU error ek_k1k1 ek_k1k2 External trip ek_k1k3 USP trip Ground ...

Page 14

... IP20 0.75 kW 1.5 kW 2.2 kW 0.4 kW 0.75 kW 1.5 kW 2.2 kW 3.7 kW Applicable standard EN61800-3: 2004 EN61800-5-1: 2003 UL508C JX Series 2.2 kW 3.7 kW 5.5 kW 7.5 kW Model 3G3JX-A2002 3G3JX-A2004 3G3JX-A2007 3G3JX-A2015 3G3JX-A2022 3G3JX-A2037 3G3JX-AE002 3G3JX-AE004 3G3JX-AE007 3G3JX-AE015 3G3JX-AE022 3G3JX-A4004 3G3JX-A4007 3G3JX-A4015 3G3JX-A4022 3G3JX-A4037 ...

Page 15

MEMO 23 ...

Page 16

Multi-functional Compact Inverters MX SYSDRIVE Nomenclature and Functions ■ Inverter Nomenclature and Functions 8k8k8k8 24 Multi-functional Compact Inverters SYSDRIVE Series Digital Operator Used to set parameters, perform various monitoring, and start and stop the Inverter. Frequency adjuster Sets the frequency ...

Page 17

Part Names and Descriptions of the Digital Operator Data display RUN command LED indicated Operation keys Name POWER LED indicator ALARM LED indicator RUN (during RUN) LED indicator PROGRAM LED indicator 8.8.8.8. Data display Data display LED indicator Volume ...

Page 18

Using Digital Operator 1. Setting the Maximum output frequency Power ON (1) 0.0 or the value previously monitored is displayed. 0.0 Press key. (2) Function code appears. dk0k0k1 Press until A --- appears. (3) A --- appears. ak-k-k- Press key. ...

Page 19

Running the motor (by potentiometer) Power ON (1) 0.0 or the value previously monitored is displayed. 0.0 Press key and turn the potentiometer clockwise. (2) The motor runs at the frequency set by the 5k0k0 potentiometer. Press key to ...

Page 20

Standard Specification List ●200-V Class Item Model name (3G3MX-) A2002 kW 0.2 Applicable motor capacity *1 HP 1/4 200 V 0.6 Rated output capacity (kVA) 220 V 0.6 Rated input voltage 3-phase (3-wire) 200 to 240 V ±10%, 50/60 Hz ...

Page 21

Common Specifications Item Enclosure rating *4 Semi-closed (IP20) Control Method Phase-to-phase sinusoidal modulation PWM Output frequency range *5 0.5 to 400 Hz Digital command: ±0.01% of the max. frequency Frequency precision *6 Analog command: ±0.2% of the max. frequency (25°C ...

Page 22

Terminal Block Specifications ● Terminal Block Position Control circuit terminal block A Control circuit terminal block B Relay output terminals Main circuit terminal block Note. This illustration shows the terminal block with the front cover removed ● Specifications of ...

Page 23

Control Circuit Terminal Specifications Control circuit terminal block A Relay Output Terminal Terminal name and function symbol External power supply terminal for input signal (input) ...At sink logic PSC Internal power supply output ...

Page 24

Dimensions 3G3MX-A2002 3G3MX-A2004 5 3G3MX-A2007 6 3G3MX-AE002 3G3MX-AE004 3G3MX-A4004 3G3MX-AE007 32 Multi-functional Compact Inverters SYSDRIVE 110±1 120 5 67±0.5 80 (7) Two, 5 dia. 118±1 130 4 5 98±0.5 110 (7) MX 2.6 D Dimensions Rated Model voltage 3G3MX- A2002 ...

Page 25

Two, 5 dia. 164±0.5 180 Two, 5 dia. 118±1 130 4 5 (7) 205±1 220 6 6.5 (7) Multi-functional Compact Inverters SYSDRIVE 6 166 5.5 ...

Page 26

Standard Connection Diagram 3-phase 200 V AC 1/3-phase 200 3-phase 400 V AC Multi-function input 1 Multi-function input 2 Multi-function input 3 Multi-function input 4 Multi-function input 5 Multi-function input 6 Sequence input common Frequency reference power ...

Page 27

Protective and Diagnostic Functions ●Error Code List Display on Digital Operator Name ek k0k1 ek k0k2 Overcurrent trip ek k0k3 ek k0k4 Overload trip *1 ek k0k5 Braking resistor overload ek k0k6 trip Overvoltage trip ek k0k7 EEPROM error *2 ...

Page 28

Model Number Explanation 3G3MX - A MX-series Inverter Standard Models Rated voltage Enclosure rating 3-phase 200 V AC IP20 1/3-phase 200 V AC 3-phase 400 V AC International Standards (EC Directives and UL/cUL Standards) The 3G3MX Inverter meets the EC ...

Page 29

MEMO 37 ...

Page 30

Advanced General-purpose Inverters RX SYSDRIVE Nomenclature and Functions ■ Inverter Nomenclature and Functions 38 Advanced General-purpose Inverters SYSDRIVE Series Digital Operator Used to set parameters, perform various monitoring, and start and stop the Inverter. Data Display Displays relevant data, such ...

Page 31

Part Names and Descriptions of the Digital Operator Data display RUN command LED indicator Operation keys Name POWER LED indicator ALARM LED indicator RUN (during RUN) LED indicator PROGRAM LED indicator 8.8.8.8. Data display Data display LED indicator RUN ...

Page 32

Using Digital Operator ■ Setting output frequency Power ON (1) 0.0 or the value previously monitored is displayed. 0.0k0k Press key. (2) Function code appears. Ddk0k0k1k Press until F001 appears. (3) F001 appears. Dfk0k0k1k Press key. (It continues in upper ...

Page 33

Operation Example for Basic Display (factory default: "b037 = 04") • Displays the limited basic parameters. Monitor mode: Function mode: Extended function mode: • Other parameters than those mentioned above are not displayed. To display all parameters, select "Complete ...

Page 34

Standard Specification List ●Three-phase 200-V Class Class Model name (3G3RX-) A2055 Max. applicable motor kW 5.5 4P 200 V 8.3 Rated output capacity (kVA) 240 V 9.9 3-phase (3-wire) 200 V −15% to 240 V +10%, 50/60 Hz ±5% Rated ...

Page 35

Common Specification Item Enclosure rating IP20 Cooling method Forced air cooling Control method Phase-to-phase sinusoidal modulation PWM Output frequency range 0.1 to 400Hz Digital command: ±0.01% of the max. frequency Frequency precision Analog command: ±0.2% of the max. frequency (25°C ...

Page 36

Item Ambient/Storage −10°C to 50°C/−20°C to 65°C/20% to 90% RH (with no condensation) temperature/Humidity Operating environ- 3G3RX-A055/-A075/-A110/-A150/-A185/-A220: 5.9 m/s Vibration * ment 3G3RX-A300/-A370/-A450/-A550: 2.94 m/s Location At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust) Feedback ...

Page 37

Terminal Block Specifications ● Terminal Block Position Digital Operator Control circuit terminal block Main circuit terminal block Note: This illustration shows the terminal block with the Terminal block front cover removed. ● Arrangement of Main Circuit Terminals Terminal arrangement ...

Page 38

Control Circuit Terminals FS FV2 AMI P24 SN SC Terminal screw size M3 Terminal Terminal name symbol Frequency reference FC common Power supply Frequency reference FS power supply output Frequency reference ...

Page 39

Terminal Terminal name symbol Multi-function output Open P4 collec- Status/ P5 tor out- Factor put Multi-function output PC common Digital (con- tact) MA Relay output MB Status, Relay alarm, output etc. Relay output MC common Analog External ...

Page 40

Dimensions 3G3RX-A2055 3G3RX-A2075 3G3RX-A2110 3G3RX-A4055 3G3RX-A4075 3G3RX-A4110 3G3RX-A2150 3G3RX-A2185 3G3RX-A2220 3G3RX-A4150 3G3RX-A4185 3G3RX-A4220 3G3RX-A2300 3G3RX-A4300 79 368 10 48 Advanced General-purpose Inverters SYSDRIVE 189 Two, 7 dia. 24 246 260 169 7 189 210 229 Two, 7 dia. ...

Page 41

Two, 12 dia. 300 520 550 12 300 390 Two, 12 dia. 380 670 700 380 480 Advanced General-purpose Inverters SYSDRIVE 250 250 RX 49 Series ...

Page 42

Standard Connection Diagram 3-phase 200 V AC 1/3-phase 200 Short-circuit 3-phase 400 V AC wire To wire the control circuit and main circuit power supplies separately, remove the J51 connector wire. Multi-function input 1 Multi-function input 2 ...

Page 43

Protective and Diagnostic Functions ●Error Code List Display on Digital Name Operator ek0k1. ek0k2. Overcurrent protection ek0k3. ek0k4. ek0k5. Overload protection *1 Braking resistor overload ek0k6. protection ek0k7. Overvoltage protection ek0k8. EEPROM error *2 *3 ek0k9. Undervoltage ek1k0. CT error ...

Page 44

Display on Digital Name Operator ek6k0. Option 1 error ek6k9. ek7k0. Option 2 error ek7k9. *1. The reset command will not be accepted until approximately 10 seconds pass since the trip occurs (protection function works) *2. The reset command will ...

Page 45

Model Number Explanation 3G3RX - A RX-series Inverter Standard Models Rated voltage Enclosure rating 3-phase 200 V AC IP20 3-phase 400 V AC International Standards (EC Directives and UL/cUL Standards) The 3G3RX Inverter meets the EC Directives and UL/cUL standard ...

Page 46

SYSDRIVE Option Specifications of Optional Items and Peripheral Devices The following optional items and peripheral devices can be used with the Inverter. Select them according to the application. (3) Input Noise Filter/ EMC-conforming Input Noise Filter (6) Digital Operator (7) ...

Page 47

JX/MX/RX Series Related Options Name Model 3G3AX-RBU21 3G3AX-RBU22 3G3AX-RBU23 Regenerative Braking 3G3AX-RBU24 Units 3G3AX-RBU41 3G3AX-RBU42 3G3AX-RBU43 3G3AX-RBA1201 3G3AX-RBA1202 3G3AX-RBA1203 3G3AX-RBA1204 3G3AX-RBB2001 Braking Resistor 3G3AX-RBB2002 3G3AX-RBB3001 3G3AX-RBB4001 3G3AX-RBC4001 3G3AX-RBC6001 3G3AX-RBC12001 3G3AX-DL2002 3G3AX-DL2004 3G3AX-DL2007 3G3AX-DL2015 3G3AX-DL2022 3G3AX-DL2037 3G3AX-DL2055 3G3AX-DL2075 3G3AX-DL2110 3G3AX-DL2150 3G3AX-DL2220 ...

Page 48

... 18 3G3JX 3G3JX 3G3MX (3-phase 200 V 0.2 to 0.75 kW, 1/3-phase 200 V 0.2 to 0.4 kW) 3G3MX (3-phase 200 V 1.5 to 3.7 kW, 3-phase 400 V 0.4 to 3.7 kW) For Position or Frequency Control PLC I/O Interface for setting Frequency, Acceleration/Deceleration time etc Cable Length 1 m Cable Length 3 m ...

Page 49

MEMO 57 ...

Page 50

Overview of Inverter Selection Selecting the Motor Capacity Select a motor before selecting the Inverter. Calculate the load inertia in the application, calculate the motor capacity and torque required to handle the load, and select an appropriate motor. ■ Simple ...

Page 51

Calculating the Combined Torque and Effective Torque Effective torque RMS Σ(Ti Σti t ...

Page 52

Overview of Inverter Selection Overview of Braking Resistor Selection ■ Applications Requiring Braking Resistors In applications where excessive regenerative motor energy is produced during deceleration or descent, the main-circuit volt- age in the Inverter may rise high enough to damage ...

Page 53

Detailed Method for Braking Resistor Selection If the Braking Resistor's use rate (duty factor) exceeds 10 the application requires an extremely large braking torque, use the following method to calculate the regenerative energy and select a Braking ...

Page 54

MEMO 62 ...

Page 55

... OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE ...

Page 56

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 57

... OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron.ca OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • ...

Related keywords