3G3JX-A2004 Omron, 3G3JX-A2004 Datasheet - Page 21

AC Motor Drive

3G3JX-A2004

Manufacturer Part Number
3G3JX-A2004
Description
AC Motor Drive
Manufacturer
Omron
Datasheet

Specifications of 3G3JX-A2004

Supply Voltage Range
200V To 240V
No. Of Phases
Three
Power Rating
400W
Output Voltage Max
240V
Output Frequency Max
400Hz
Mounting Type
DIN Rail
Output Voltage Min
200V
External Height
155mm
Frequency Range
0.5 To 400Hz
Rohs Compliant
Yes
External Depth
109.5mm
External Width
80mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Common Specifications
*1. The applicable motor is a 3-phase standard motor. For using any other type, be sure that the rated current does not exceed that of the Inverter.
*2. Output voltage decreases according to the level of the power supply voltage.
*3. The braking torque at the time of capacitor feedback is an average deceleration torque at the shortest deceleration (when it stops from 50 Hz), not a continuous
*4. Protection method complies with JEM 1030.
*5. To operate the motor at over 50/60 Hz, contact the motor manufacturer to find out the maximum allowable revolution.
*6. For motor stabilization, the output frequency may exceed the maximum frequency set in A004 (A204) by 2 Hz max.
Enclosure rating
Control
Protective Functions
Input signal Multi-function input
Output
signal
Other functions
General
specifica-
tions
Options
regeneration torque. Also, the average deceleration torque varies depending on the motor loss. The value is reduced in operation over 50 Hz. Note that no regen-
erative braking circuit is built into the Inverter. If you need a larger regenerative torque, use the optionally available regenerative braking unit and resistor.
The regenerative braking unit should be used only for short-time regeneration.
Control Method
Output frequency range
Frequency precision
Frequency setting
resolution
Voltage/Frequency
characteristics
Overload current rating
Acceleration/
Deceleration time
Start torque
Carrier frequency
modification range
DC injection braking
Multi-function output
Frequency monitor
Relay output
Ambient temperature
Ambient storage
temperature
Humidity
Vibration
Location
Applicable standard
*4
Item
*6
*5
Semi-closed (IP20)
Phase-to-phase sinusoidal modulation PWM
0.5 to 400 Hz
Digital command: ±0.01% of the max. frequency
Analog command: ±0.2% of the max. frequency (25°C ±10°C)
Digital setting:
Analog setting: Max. frequency/1000
V/f characteristics (constant/reduced torque)
150% for 1 min
0.01 to 3000 s (line, S-shape curve), 2nd acceleration/deceleration setting available
200% min./1 Hz
2.0 to 14.0 kHz
Starts at a frequency lower than that in deceleration via the STOP command, or via an external input.
(Level and time settable.)
Overcurrent, overvoltage, undervoltage, electronic thermal, temperature error, ground-fault overcurrent at power-on
state, overload limit, incoming overvoltage, external trip, memory error, CPU error, USP error, internal communication
error, BRD error, overvoltage protection during deceleration, overcurrent suppression
FW (forward), RV (reverse), CF1 to CF4 (multi-step speed), RS (reset), AT (current input selection), USP (USP function),
EXT (external trip), OPE (forced OPE mode), STA (3-wire startup), STP (3-wire stop), F/R (3-wire forward/reverse),
FRS (free run stop), JG (jogging), 2CH (2-step acceleration/deceleration), DB (external DC injection braking),
SET (2nd function), UP (remote operation/accelerate), DWN (remote operation/decelerate), PID (PID selection),
PIDC (PID deviation reset), PTC (thermistor input), UDC (data clear of UP/DWN function), SFT (soft lock),
ADD (frequency addition), F-TM (forced terminal block), RDY (operation ready), SP-SET (special setting)
RUN (signal during operation), FA1 (frequency arrival signal), FA2 (frequency arrival signal),
OL (overload warning signal), OD (PID excess deviation signal), AL (alarm signal),
ODC (communication option disconnected), FBV (PID FB status output), NDc (Network error),
LOG (Logic operation output)
Analog meter (0 to 10 V DC, 1 mA max.),
Frequency/Current signals are selectable via the analog output terminal.
The relay (SPDT contact) outputs signals corresponding to the multi-function output.
AVR function, V/f characteristic selection, line acceleration/deceleration, upper/lower limit, 16-step speeds, starting
frequency adjustment, jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias
adjustment, S-shape acceleration/deceleration, electronic thermal characteristics/level adjustment, retry function,
automatic torque boost, trip monitor, soft lock function, frequency conversion display, USP function, 2nd control function,
motor rotation speed UP/DOWN, fan ON/OFF function
−10°C to 40°C (Carrier frequency: 5 kHz max.)
−10°C to 50°C (Both the carrier frequency and output current need to be reduced)
−20°C to 65°C (short-time temperature during transport)
20% to 90% RH
5.9 m/s
(Complies with the test method specified in JIS C0040 (1999).)
At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Complies with UL, cUL, CE standards. (Insulation distance)
Noise filter, AC/DC reactors, regenerative braking unit and resistor, etc.
2
(0.6G), 10 to 55 Hz
Multi-functional Compact Inverters SYSDRIVE
0.1 Hz
Specifications
MX
Series
29