ATV12HU40M3 SQUARE D, ATV12HU40M3 Datasheet - Page 15

AC Drive

ATV12HU40M3

Manufacturer Part Number
ATV12HU40M3
Description
AC Drive
Manufacturer
SQUARE D
Datasheets

Specifications of ATV12HU40M3

No. Of Phases
Three
Power Rating
3.7kW
Output Voltage Max
230V
Output Current
16.7A
Supply Voltage Max
230V
Frequency Range
0.5 To 400Hz
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Specifications
Protocol
Structure
Services
1,50
1,25
0,95
0,75
0,50
0,25
The device can power any motor which has a lower rating than that for which the drive was designed, provided that the minimum current value
is complied with: Ith = 0.2 x drive In.
For motor ratings slightly higher than that of the drive, check that the current taken does not exceed the continuous output current of the drive.
Connecting motors in parallel
Motor switching is possible with the drive unlocked. The integrated protection in Altivar
breaking of the powered motor.
Introduction:
page 8
Diagnostics
T/Tn
Drive In > In1 + In2 + Inx
L = L1 + L2 + Lx
Communication port specifications
Torque specifications
Special uses
Use with a motor with different power to the drive rating
Connecting motors in parallel
Motor switching at the drive output
1,7
2
1
0
Altivar 12
0
4
3
2
1
25/30
Motor
choke
2
1
50/60
L2
Lx
L1
Connector
Physical interface
Transmission mode
Transmission speed
Number of subscribers
Polarization
Address
Profile
Messaging
Communication monitoring
Via the Human/Machine interface
or remote display terminal
(continued)
References:
page 14
L
5
(typical curves)
75/90
In1
In2
Inx
100/120
M1
M2
M3
Hz
Altivar
variable speed drives
The curves opposite define the available continuous torque and transient overtorque
for both self-cooled and force-cooled motors.
The only difference is in the ability of the motor to provide a high continuous torque at
less than half the nominal speed.
1
2
3
4
5
(1) For power ratings y 250 W, de-rating is 20% instead of 50% at very low frequencies.
(2) The nominal motor frequency and the maximum output frequency can be adjusted from
0.5 to 400 Hz. The mechanical overspeed capability of the selected motor must be checked with
the manufacturer.
The drive rating must be greater than or equal to the sum of the currents of the
motors to be connected to the drive (In). In this case, it is necessary to provide
external thermal protection for each motor using probes or thermal overload relays.
Use of a motor choke (1) is recommended in the following cases:
When three or more motors are connected in parallel
When the motor cable length (L), including all tap links (L1, L2 to Lx), is longer than
the maximum permitted motor cable length (2)
(1) See References on page 17.
(2) For maximum permitted motor cable length, see page 11.
Dimensions:
page 18
Self-cooled motor: continuous useful torque
Force-cooled motor: continuous useful torque
Transient overtorque for 60 s
Transient overtorque for 2 s
Torque in overspeed at constant power
Modbus
1 RJ45 connector
2-wire RS 485
RTU
Configurable via the Human/Machine interface, remote display terminal or SoMove
setup software: 4800 bps, 9600 bps, 19200 bps or 38400 bps
31 maximum
No polarization impedance. This must be provided by the wiring system (for example,
in the master)
1 to 247, configurable via the Human/Machine interface, remote display terminal or
SoMove setup software
Based on IEC 61800-7-301 (CiA 402 profile)
Read Holding Registers (03) 29 words maximum
Write Single Register (06) 29 words maximum
Write Multiple Registers (16) 27 words maximum
Read/Write Multiple Registers (23) 4/4 words maximum
Read Device Identification (43)
Can be inhibited. Time out can be set between 0.1 s and 30 s
On display unit
®
®
12
®
12 drives offers better immunity to downstream
Connections:
page 22
(2)
(1)
Functions:
page 26
13
10
1
2
3
4
5
6
7
8
9

Related parts for ATV12HU40M3