ATV12HU40M3 SQUARE D, ATV12HU40M3 Datasheet - Page 26

AC Drive

ATV12HU40M3

Manufacturer Part Number
ATV12HU40M3
Description
AC Drive
Manufacturer
SQUARE D
Datasheets

Specifications of ATV12HU40M3

No. Of Phases
Three
Power Rating
3.7kW
Output Voltage Max
230V
Output Current
16.7A
Supply Voltage Max
230V
Frequency Range
0.5 To 400Hz
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
10
1
2
3
4
5
6
7
8
9
Combinations for
customer assembly
Q1:
C60N2P
A1:
ATV12ppppF1,
ATV12ppppM2
Introduction:
page 8
KM1:
TeSys LC1ppp
(if control circuit)
Motor starter with single-phase power supply
M1:
200..240 V three-phase
asynchronous motor
24
or
3
M1
Specifications:
page 10
Q1:
GV2pppp
Altivar
variable speed drives
Motor starters: Single-phase supply voltages
100 to 120 V and 200 to 240 V
The proposed combinations can:
b Protect people and equipment (when a short-circuit occurs)
b Maintain protection upstream of the drive in the event of a short-circuit on the
Two types of combination are possible:
b Drive + circuit-breaker: Minimum combination
b Drive + circuit-breaker + contactor: Minimum combination with contactor when a
M1
0.18
0.37
0.75
0.18
0.37
0.55
0.75
1.5
2.2
(1) For a complete list of references for TeSys contactors, please refer to the "Motor starter
solutions - Control and protection components" and "Motor starters up to 150 A" catalogs or visit
"www.schneider-electric.us".
(2) Motor power indicated for combination with an ATV12Hppppp drive with the same rating. For
combination with an ATV12Pppppp drive, refer to the specific manual for the Altivar
plate version, available on our website at “www.schneider-electric.us”.
(3) TeSys motor circuit-breakers:
- GV2MEpp: Thermal magnetic motor circuit-breakers with pushbutton control
- GV2Lpp: Magnetic motor circuit-breakers with control by rotary knob
(4) 2-pole C60N modular circuit-breaker
(5) Can be integrated in devices connected to a power socket:
- If the line current is y 16 A, connection to a single-phase power socket, 10/16 A 250 V z
- If the line current is > 16 A, connection to a single-phase power socket conforming to standard
IEC 60309
References:
page 14
Applications
Motor starters
Standard
power
ratings of
three-phase
4-pole
50/60 Hz
motors
(2)
kW
Single-phase supply voltage: 100 to 120 V 50/60 Hz (5)
Single-phase supply voltage: 200 to 240 V 50/60 Hz (5)
power stage
control circuit is needed
0.25
0.5
1
0.25
0.55
0.75
1
2
3
HP
Variable speed
drive
A1
ATV12H018F1
ATV12p037F1
ATV12H075F1
ATV12H018M2
ATV12p037M2
ATV12p055M2
ATV12p075M2
ATV12HU15M2
ATV12HU22M2
®
12
Dimensions:
page 18
Q1
GV2ME14
GV2L10
2-pole C60N
GV2ME16
GV2L16
2-pole C60N
GV2ME21
GV2L22
2-pole C60N
GV2ME08
GV2L08
2-pole C60N
GV2ME14
GV2L10
2-pole C60N
GV2ME14
GV2L14
2-pole C60N
GV2ME16
GV L16
2-pole C60N
GV2ME21
GV2L20
2-pole C60N
GV2ME32
GV2L22
2-pole C60N
Combination with control circuit
(circuit-breaker + contactor)
Minimum combination
(circuit-breaker only)
TeSys
circuit-breaker
(3)
Modular
circuit-breaker
(4)
®
motor
Operating
range or
rating
A
6 to 10
6.3
10
9 to 14
14
16
17 to 23
25
20
2.5 to 4
4
6
6 to 10
6.3
10
6 to 10
10
10
9 to 14
14
16
17 to 23
18
20
24 to 32
25
32
Connections:
page 22
Maximum
short-circuit
current Icu
kA
> 100
> 100
10
> 100
> 100
10
50
> 50
10
> 100
> 100
10
> 100
> 100
10
> 100
> 100
10
> 100
> 100
10
50
> 100
10
50
50
10
®
KM1
LC1K09
LC1K12
LC1D25
LC1K09
LC1K09
LC1K09
LC1K12
LC1D18
LC1D25
TeSys
contactor
(1)
12 base

Related parts for ATV12HU40M3