ATC18002 PANASONIC EW, ATC18002 Datasheet
ATC18002
Related parts for ATC18002
ATC18002 Summary of contents
Page 1
... Hz (cps)/ count KHz (Kcps) • Maintain output/over switchable count III • One shot/over count (4 modes rubber gasket (ATC18002) and a mounting frame (AT8-DA4) are included. 90 FEATURES 1. Two-stage presetting (upper and lower limits) SET2 SET1 Output 1 Output 2 2. Bright and Easy-to-Read Display A brand new bright 2-color backlight LCD display ...
Page 2
PART NAMES Setting value 1/2 selector COUNTER LC4H-W Controlled output indicator OP 1 Lock indicator LOCK RESET Reset switch SET/LOCK Set/lock switch Sixth digit First digit SPECIFICATIONS Item Rated operating voltage Rated frequency Power consumption Control output ...
Page 3
... OP 2.598 1.752 1.890 LOCK RESET SET/LOCK 63.5 2.500 • Installation panel cut-out dimensions The standard panel cut-out dimensions are shown below. Use the installation frame (AT8-DA4) and rubber gasket (ATC18002). 80 min. 3.150 +0 +.024 1.772 0 +0 +.024 1.772 0 80 min. 3.150 ...
Page 4
SETTING THE OPERATION MODE AND COUNTER Setting procedure 1) Setting the output mode (output 1, 2) Set the input 1, 2 modes with the DIP switches on the side of the unit. DIP switches Item 1 2 Output mode 3 ...
Page 5
LC4H-W OPERATION MODE 1. Input mode Q For the input mode, you can choose one of the following five modes. • Addition UP • Subtraction DOWN • Directive DIR • Independent IND • Phase PHASE W After the counter has ...
Page 6
Output mode For the set value 1, you can choose one of the following four modes. • Maintain output/over count I HOLD-B • Maintain output/over count II HOLD-C • Maintain output/over count III HOLD-D • One shot/over count SHOT-A ...
Page 7
LC4H-W • Output mode for set value 2 Output mode Operation Output control is maintained after count-up completion and until resetting. During that time, the count display does not change from that at count-up com- Maintain output pletion. Hold count ...
Page 8
Output mode Operation Output control is maintained after count-up completion for a fixed time (approx. 1 sec). Counting is possible despite completion of count-up. One shot However, reset occurs simultaneous Recount II with output OFF. SHOT-C Output control is maintained ...
Page 9
LC4H series CAUTIONS FOR USE PRECAUTIONS DURING USAGE 1. Terminal wiring 1) When wiring the terminals, refer to the terminal layout and wiring diagrams and be sure to perform the wiring properly without errors. 2) For embedded installation applica- tions, ...
Page 10
The second-phase side must not be ground- ed. 4) Since the power supply circuitry does LC4H counter Input Power terminals supply Circuit Insulated transformer is necessary not contain a transformer, ...
Page 11
Self-diagnosis function If a malfunction occurs, one of the following displays will appear. Display Contents Minimum value went below –999 or or –99999. See note 1. Incorrect DIP switch setting. Malfunctioning CPU. Malfunctioning memory. See note 2. Note 1: ...