ATC18002 PANASONIC EW, ATC18002 Datasheet - Page 2

no-image

ATC18002

Manufacturer Part Number
ATC18002
Description
PMH(48M.M.) RUBBER GASKET
Manufacturer
PANASONIC EW
Datasheet
PART NAMES
SPECIFICATIONS
Rating
Contact
Life
Electrical
Mechanical
Operating
conditions
Connection
Protective construction
Note: 1) the 24V AC type can be operated also with 24V DC.
Controlled output indicator
Setting value 1/2 selector
Set/lock switch
Lock indicator
Reset switch
Rated operating voltage
Rated frequency
Power consumption
Control output
Input mode
Counting speed
Min. counting input time
Reset input method
Input signal
Output mode
One shot output time
Indication
Digit
Memory
Contact arrangement
Initial contact resistance
Contact material
Mechanical
Electrical
Operating voltage range
Initial withstand voltage
Initial insulation resistance
(At 500 V DC)
Temperature rise
Vibration
resistance
Shock
resistance
Ambient temperature
Ambient humidity
Air pressure
Ripple rate
Item
SET/LOCK
COUNTER
Sixth digit
RESET
Functional
Destructive
Functional
Destructive
OP
1 2
LOCK
1
2
LC4H-W
(under the flow of nominal operating current at nominal voltage)
Between live and dead metal parts: 2,000 Vrms for 1 min (pin type)
First digit
Between live and dead metal parts: Min. 100 MΩ (pin type)
Addition (UP)/Subtraction (DOWN)/Direction (DIR)/Individuality (IND)/Phase (PHASE) 5 modes selectable by DIP switch
50/60 Hz common
100 to 240 V AC
Between input and output: 2,000 Vrms for 1 min
Between open contacts: 1,000 Vrms for 1 min
Max. 10 V A
Min. 1.0 × 10
24 V AC
AC type
Between input and output: Min. 100 MΩ
Between open contact: Min. 100 MΩ
Counter display
1 Form C: 3 A, 250 V AC (resistive)
Set value display
Contact or Open collector input/Input impedance: 1 kΩ or less, Input residual voltage: 2 V or less,
Up key
1)
7-segment LCD, Counter value (backlight red LED), Setting value (backlight yellow LED)
100 mΩ (at 1 A 6 V DC)
Min. 2.0 × 10
Signal reset/Push-key switch, Min. input time 1 ms, 20 ms (selected by DIP switch)
5
Ralay output type
10 to 55 Hz (1 cycle/min), single amplitude: 0.35 mm
Ag alloy/Au flush
ope. (At rated control voltage)
10 to 55 Hz (1 cycle/min), single amplitude: 0.75 mm
Max. 65°C
1a+1a
16.7 ms at 30 Hz(cps)/0.1 ms at 5 KHz(cps) ON time: OFF time = 1:1
Open impedance: 100 kΩ or more, Max. energized voltage: 40 V DC
–99999 to 999999 (–5 digits to 6 digits) (0 to 999999 for setting)
02/2003
7
ope.
Output 2. HOLD-A, B, C SHOT-A, B, C, D (8 modes)
30 Hz(cps)/5 KHz(cps) (selectable by DIP switch)
EEP-ROM (Overwriting times: 10
12 to 24 V DC
Min. 294 m
20 % or less
Output 1. HOLD-B, C, D SHOT-A (4 modes)
Min. 98 m
Max. 3 W
DC type
85 to 110 % of rated operating voltage
IP66 (front panel with a rubber gasket)
SET/LOCK key
–10°C to 55°C
RESET key
(selectable by DIP switch)
UP keys
321.522
11-pin/screw terminal
964.567
860 to 1,060 h Pa
Max. 85 % RH
Approx. 1 s
ft./s
ft./s
+14°F to +131°F
2
2
(4 times on 3 axes)
Between live and dead metal parts: Min. 100 MΩ (pin type)
: Used to set the corresponding digits for the
: Used to reset counting and its output.
: Used to select between the Setting 1 display
(5 times on 3 axes)
1 Form A: 100 mA, 30 V DC Open collector output (Max.)
Between live and dead metal parts: 2,000 Vrms for 1 min
count-up mode.
and Setting 2 display and to lock the keys
(UP and RESET keys not responsive to
touch). Used also to set and confirm the
input mode.
50/60 Hz common
100 to 240 V AC
Between input and output: 2,000 V AC for 1 min
5
Max. 10 V A
Min. 1.0 × 10
ope. or more)
24 V AC
AC type
Between input and output: Min. 100 MΩ
.014 inch
.030 inch
1)
1a+1a (Open collector)
Transistor output type
(10 min on 3 axes)
7
(1 h on 3 axes)
ope. (At rated control voltage)
12 to 24 V DC
20 % or less
Max. 3 W
DC type
LC4H-W
91