V45450-2 VEEDER ROOT, V45450-2 Datasheet - Page 123

Multifunction Counter

V45450-2

Manufacturer Part Number
V45450-2
Description
Multifunction Counter
Manufacturer
VEEDER ROOT
Type
Counterr
Datasheets

Specifications of V45450-2

No. Of Digits / Alpha
8
Digit Height
10mm
Counting Speed
10kHz
Operating Temperature Range
0°C To +55°C
Character Size
10mm
Panel Cutout Width
1.77"
Connection Type
Screw
Counter Type
Predetermining
Cut Out, Panel
1/16 DIN
Dimensions
1.89"L×4.33"W×1.89"H
Display Digit Height
10mm (Top Display), 7mm (Bottom Display)
Display Type
LED
Frequency, Operating
50⁄60 Hz
Function
Counter
Input Type
NPN
Mounting Type
Panel
Number Of Digits
8
Primary Type
Electronic
Standards
UL and cUL Recognized, CE Marked
Temperature, Operating, Range
0 to +50 °C
Terminal Type
Screw Terminal
Termination
Screw Terminal
Voltage, Supply
90 to 264 VAC
Weight
7 Oz.
Input Signals Accepted From A Variety Of Sources
Dry Contact, PNP or NPN Sensors, Encoders
Lead Free Status / RoHS Status
na
OUTPUT 1 OPERATING MODES CONT.
ONTimed Pulse Output
Timed Pulse and Repeat
Repeat Cycle, ON or OFF Time Cycle First
MOUNTING
The SX400 timer uses two removable mounting clips with adjustable screws to mount the enclosure in a panel as shown below.
ORDERING INFORMATION
Output 1 is energized for a programmable pulse time up to 99.99
seconds at the end of the timing cycle.
Output 1 is energized for a programmable pulse time up to 99.99
seconds at the end of the timing cycle with the time cycle automati-
cally repeating.
RESET TIMINGTIMING
Output 1 is energized and deenergized in repeating operation with
either the ON or OFF time period first. The time periods are equal
length. Unequal length time intervals can be obtained using the
Early Trip prewarn output.
RESET TIME
RESET TIMING
(75.69)
2.98
OUTPUT TYPE
PULSE PULSE
Sym.
PULSE
TIME
TIME
10
30
(75.69)
2.98
Time Ranges: 99.99 Sec., 999.9 Sec.,
99 Min.: 59 Sec., and 99 Hr.: 59 Min.
Time Ranges: 99.99 Min., 999.9 Min.,
99.99 Hr., and 999.9 Hr.
TIMING RESET
TIMING COMPLETE
TIME
Description
TIME
RESET
SX4
PANEL CUTOUT
SQUARE
2.72
(68
+0.7
-0.0
+0.028
-0.000
)
10
OUTPUT 2 OPERATING MODES
TERMINAL ASSIGNMENTS
(5.84)
0.23
Output 2 can be programmed to operate in parallel with Output 1,
providing DPDT relay operation form the two SPDT relays, or it can be
programmed as an Early Trip prewarn output that is energized at a
predetermined time before the end of the cycle. An example of Early
Trip prewarn operation with the ON Delay mode for Output 1 is shown
here for reference.
OUTPUT 2
OUTPUT 1
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
A6
yy
yy
yy
yy
VOLTAGE & FREQUENCY
yyy
yyy
yyy yy
OUTPUT 1
Sym.
yy
RESET TIMING
A6
B6
PANEL THICKNESS (STEEL)
0.125 – 0.313 (3.125 – 7.825)
120 VAC, 50/60 Hz
240 VAC, 50/60 Hz
Description
(127.0)
5.00
COMPLETE RESET
OUTPUT 2
TIMING
OFF
ON
1
SWITCH
2
3
4
0.50 REQUIRED
FOR WIRING
5
6
7
8
5.29
T
O
T
A
Z
N
G
L
I
I
E
L
E
C
T
R
O
N
C
I
5
M
R
T
E
S
I

Related parts for V45450-2