CUB5VB00 Red Lion Controls, CUB5VB00 Datasheet - Page 8

Voltage Meter

CUB5VB00

Manufacturer Part Number
CUB5VB00
Description
Voltage Meter
Manufacturer
Red Lion Controls
Type
Voltager
Datasheet

Specifications of CUB5VB00

No. Of Digits / Alpha
5
Meter Function
DC Voltmeter
Meter Range
0mV To 200mV / 0V To 2V / 0V To 20V / 0V To 200V
Digit Height
12.2mm
Operating Temperature Range
-35°C To +75°C
Meter Signal Input
Voltage
Accuracy
±0.1% %
Connection Type
Screw
Cut Out, Panel
2.68×1.3 "
Dimensions
2.95"L×1.86"W×1.54"H
Display Digit Height
0.48 "
Display Type
LCD
Function
Voltage
Material, Casing
Plastic
Number Of Digits
5
Primary Type
Electronic
Range, Measurement
200 mVDC to 200 VDC
Special Features
Communication and Control
Voltage, Supply
9 to 28 VDC
Power Supply
9 to 28 VDC
Dc Current
200 μA to 200 mA
Dc Voltage
200 mV to 200 V
Process Signals
0(4) to 20 mA or 0 - 10 VDC
Display Mode
Selectable Transmissive
Rohs Compliant
Yes
Backlighting Color
Red Or Green
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
delay time, the meter will capture that display value as the new MAX reading.
A delay time helps to avoid false captures of sudden short spikes.
time, the meter will capture that display value as the new MIN reading. A delay
time helps to avoid false captures of sudden short spikes.
USrIN
HI-En
HI-t
LO-En
LO-t
FCS
DISPLAY
6.2 MODULE 2 - S
Select
Enables the Maximum Display Capture capability.
When the Input Display is above the present MAX value for the entered
Enables the Minimum Display Capture capability.
When the Input Display is below the present MIN value for the entered delay
P-Loc
rESEt
d-HLd
d-SEL
d-LEV
COLOr
ZErO
NO
yES
No Function
Program Mode Lock-out
Zero Input
(Edge triggered)
Reset (Edge triggered)
Display Hold
Display Select
(Edge Triggered)
Display Intensity Level
(Edge Triggered)
Backlight Color
(Edge Triggered)
MODE
to perform either of the Factory Service Operations shown below.
2. 0
2. 0
NO
NO
NO
NO
FACTORY SERVICE OPERATIONS
MAX CAPTURE DELAY TIME
MIN CAPTURE DELAY TIME
USER INPUT FUNCTION
MAX DISPLAY ENABLE
MIN DISPLAY ENABLE
NO
SEL
0. 0
0. 0
2-SEC
HI-En
Max Display
NO
to
Enable
to
NO
999. 9
999. 9
YES
DESCRIPTION
User Input disabled.
See Programming Mode Access chart
(Module 3).
Zero the Input Display value causing
Display Reading to be Offset.
Resets the assigned value(s) to the
current input value.
Holds the assigned display, but all other
meter functions continue as long as
activated (maintained action).
Advance once for each activation.
Increase intensity one level for each
activation (backlight version only).
Change backlight color with each
activation (backlight version only).
seconds
seconds
yES
YES
HI-t
Max Capture
Delay Time
ECONDARY
LO-En
Min Display
PARAMETER MENU
Enable
F
LO-t
Min Capture
8
Delay TIme
UNCTION
values no longer accurately define the input circuit. For most applications,
recalibration every 1 to 2 years should be sufficient.
should only be performed by individuals experienced in calibrating electronic
equipment. Allow a 30 minute warm up before performing any calibration
related procedures. The following procedures should be performed at an
ambient temperature of 15 to 35°C (59 to 95°F).
Voltage Calibration
1. Connect a precision DC voltage source with an accuracy of 0.01% or better
2. With the display at
3. Press the
4. Press the
5. With the voltage source set to zero (or a dead short applied to the input), press
6. When the display reads the selected range, apply full-scale input signal for
7. Repeat steps 3 through 6 for each input range to be calibrated. When display
Input Assignment only applies if a selection of reset, display hold, or print and
reset is selected in the User Input Function menu.
U-ASN
CodE
CodE
CodE
DISPLAY
Calibration of the CUB5V involves an input voltage calibration, which
CAUTION: The accuracy of the calibration equipment will directly affect the
to the INP+ (positive) and COMM (negative) terminals of the CUB5V. Set
the output of the voltage source to zero.
will display
SEL
the range. (Note: For 200V range, apply 100V as indicated on the display.)
Press
reads
Select the value(s) to which the User Input Function is assigned. The User
Print
P-r5t
rSt-1
rSt-2
rSt12
accuracy of the CUB5V.
. Display reads
SEL
CAL NO
Print Request
Print and Reset
Setpoint 1 Reset
Setpoint 2 Reset
Setpoint 1 and 2 Reset
MODE
RESTORE FACTORY DEFAULT SETTINGS
dSP
FCS
RST
SEL
. Display reads
66
50
48
Operations
, press the
CAL NO
Factory
Service
button to select the range to be calibrated.
button. Display reads
P
provide accurate voltage measurements. Over time, the
electrical characteristics of the components inside the meter
will slowly change, with the result that the stored calibration
the factory settings. The meter will display
return to
meter. The display then returns to
button to exit the module.
.
USER INPUT ASSIGNMENT
CodE 48
ARAMETERS
CALC
VIEW VERSION DISPLAY
The CUB5V uses stored voltage calibration values to
Entering Code 66 will overwrite all user settings with
Entering Code 50 will display the version (x.x) of the
SEL
for about 8 seconds.
CALC
, press and hold the
CodE 00
CALIBRATION
button to exit calibration.
Access Code
CodE
For Service
Operations
for about 8 seconds.
HI
LO
DESCRIPTION
Serial transmit of the active parameters
selected in the Print Options menu
(Module 5).
Same as Print Request followed by a
momentary reset of the assigned value(s).
Resets setpoint 1 output.
Resets setpoint 2 output.
Reset both setpoint 1 and 2 outputs.
. Press the SEL button to exit the module.
0. 0 v
HI-LO
.
Pro
dSP
SEL
(
2-SEC
button for 2 seconds. Unit
CodE 00
)
. Press the SEL
rESEt
and then