PAXCK010 Red Lion Controls, PAXCK010 Datasheet - Page 12

Digital Multifunction Timer

PAXCK010

Manufacturer Part Number
PAXCK010
Description
Digital Multifunction Timer
Manufacturer
Red Lion Controls
Datasheet

Specifications of PAXCK010

Time Range
0.001sec To 1hr
Power Consumption
14W
Supply Voltage Dc, Min
11V
Signal Input Type
Pulse
Supply Voltage
24VAC
Supply Voltage Max
36VDC
Time Range Max
999999h
Character Size
0.56"
Display Font Color
Red
No. Of Digits / Alpha
6
Supply Voltage Dc, Max
36V
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
is running or stopped/inhibited. Select
does not apply to
front panel Function Keys.
specific meter control functions. While in the Display Mode, the function is
executed when the User Input transitions to the active state. Refer to the User
Input specifications for active state response times. Certain User Input functions
are disabled in “Full” Programming Mode. User Inputs should be programmed
while in the inactive state.
programmable to perform specific meter control functions. While in the Display
Mode, the primary function is executed when the key is pressed. Holding the
F1 or F2 Function Keys for three seconds executes a secondary function. It is
possible to program a secondary function without a primary function. The front
panel key functions are disabled in both Programming Modes.
programmed for the same function, the maintained (level active) functions will
be performed while at least one of those User Inputs or Function Keys are
activated. The momentary (edge triggered) functions are performed every time
any of those User Inputs or Function Keys transition to the active state.
pressed at the listed function. A sublist provides yes/no selection for Display
Values or Setpoints which pertain to the programmed function. The function
will only be performed on the parameters entered as
Input or Function Key is configured for a function with a sublist, then that
sublist will need to be scrolled through each time, in order to access any
parameters for the User Inputs or Function Keys which follow.
all user inputs and function keys except the Reset (RST) Key.
6.2 MODULE 2 - U
This parameter allows the Timer annunciator (TMR) to flash when the Timer
Determines the “Run/Stop” State of the Timer at Power-up. This parameter
Module 2 is the programming module for the rear terminal User Inputs and
Three rear terminal User Inputs are individually programmable to perform
Three front panel Function Keys, F1, F2 and RST, are also individually
In most cases, if more than one User Input and/or Function Key is
Some functions have a sublist of parameters, which appears when
With this selection, NO function is performed. This is the factory setting for
- Timer Stopped at power-up, regardless of prior run/stop state
- Timer assumes the same run/stop state it was in prior to power-down
TIMER INPUT STATE AT POWER-UP
FLASH TIMER ANNUNCIATOR
timer input operation.
NO FUNCTION
if a flashing indicator is not desired.
SER
in the sublist. If a User
I
PARAMETER MENU
NPUT AND
P
ARAMETERS
PAR
is
12
In Module 3, certain parameters can be setup where they are still accessible
during Programming Mode Lock-out. A security code can be configured to
allow complete programming access during User Input lock-out. This parameter
does not apply to the function keys. Program only one user input for this function.
Stop Values; Setpoint On/Off and Time-Out Values; and Setpoint Daily On/Off
Occurrence (for Real-Time Clock option). The two lists are named
the User Input is in the inactive state and
Input is in the active state (maintained action). If a front panel Function Key is
used to select the list, then the list will toggle for each key press (momentary
action). The display will only indicate which list is active when the list is
changed or when entering any Programming Mode.
programming of all the parameters. Exit programming and switch to the other
list. Re-enter programming and enter the Timer/Counter Start and Stop Values
(
Time-Out Values (
(
other parameters are changed, the other list values must be reprogrammed.
Program only one user input for this function.
Note: When downloading the Crimson
The Timer can be programmed to Reset at each meter power-up.
Programming Mode is locked-out, as long as activated (maintained action).
Two lists of parameter entries are available for the Timer/Counter Start and
To program the values for
sure that both the software and meter have the same list active. The active
list in the Crimson
and/or Setpoint Alarms category.
F
RONT
. If a User Input is used to select the list, then
,
,
,
(
PROGRAMMING MODE LOCK-OUT
,
,
,
EXCHANGE PARAMETER LISTS
TIMER RESET AT POWER-UP
P
®
,
ANEL
,
program is the one being displayed in Input Setup
,
,
)
,
), and if applicable, the Setpoint On/Off and
), and the Setpoint Daily On/Off Occurrence
,
,
F
®
UNCTION
,
program containing List A/B, make
and
,
,
is selected when the User
,
, first complete the
,
,
is selected when
K
EY
,
). If any
and
,

Related parts for PAXCK010