PAXCK010 Red Lion Controls, PAXCK010 Datasheet - Page 19

Digital Multifunction Timer

PAXCK010

Manufacturer Part Number
PAXCK010
Description
Digital Multifunction Timer
Manufacturer
Red Lion Controls
Datasheet

Specifications of PAXCK010

Time Range
0.001sec To 1hr
Power Consumption
14W
Supply Voltage Dc, Min
11V
Signal Input Type
Pulse
Supply Voltage
24VAC
Supply Voltage Max
36VDC
Time Range Max
999999h
Character Size
0.56"
Display Font Color
Red
No. Of Digits / Alpha
6
Supply Voltage Dc, Max
36V
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
programmed for Timed Output mode (
is the Setpoint Output time duration, from activation to deactivation. This value
is always entered in minutes, seconds, and hundredths of seconds format. The
maximum Time-Out Value is 99 minutes 59.99 seconds.
Real-Time Clock Time display (
the week when the Setpoint output will activate.
days entered as
as
occur every week on the chosen day(s).
Setpoint One-Shot Mode
a One-shot setpoint is enabled (armed), the setpoint output will activate at the
set time and disable itself from activating again. To enable or re-enable a one-
shot alarm, go to the Setpoint value entry display and press the Up or Dn key
repeatedly while the AM/PM digit is selected (flashing). When the 2nd digit
decimal point is lit, the Setpoint is enabled. The Setpoint enable status is saved
at power-down. The enable state of the Setpoint is not affected or changed when
the Parameter List is exchanged.
Action selected. If
shot status can also be viewed or set from the Setpoint Off value entry display.
Real-Time Clock Time display (
is programmed for On-Off Output mode (
determines the days of the week when the Setpoint output will deactivate.
days entered as
as
will occur every week on the chosen day(s).
PAXCK: DAILY ON OCCURRENCE
PAXCK: DAILY OFF OCCURRENCE
The Time-Out Value only appears when the Setpoint Action (
This parameter only appears when the Setpoint is assigned (
Selecting
If all days are set to
The setpoint will turn off (de-activate) as programmed per the Setpoint
This parameter only appears when the Setpoint is assigned (
Selecting
to have the Setpoint turn off at the next Daily Off Occurrence. The One-
, the output will not activate. The output activation is repetitive, and will
, the output will not deactivate. The output deactivation is repetitive, and
displays a sublist for choosing the days of the week. On all
displays a sublist for choosing the days of the week. On all
DISPLAY
DISPLAY
in the sublist, the output will deactivate. On all days entered
in the sublist, the output will activate. On all days entered
, the Setpoint will operate in “One-shot” mode. When
mode is selected, program all the Daily Off days to
TIME-OUT VALUE
DESCRIPTION
Wednesday
Thursday
DESCRIPTION
Saturday
Tuesday
Wednesday
Monday
Sunday
Friday
Thursday
Saturday
Tuesday
Monday
Sunday
Friday
). This parameter determines the days of
) and when the Setpoint Action (
to
). In this mode, the Time-Out Value
). In this mode, this parameter
FACTORY
FACTORY
) to the
) to the
) is
)
19
Normal (
Reverse (
Flash (
Off (
Select
condition (event) for the Setpoint On or Setpoint Off parameters.
automatically resets the Setpoint Assignment display (
Setpoint output should not cause the assigned display to reset. Does not apply
to manual activations or deactivations by user input, function key, or serial
communications.
Assignment display (
reset when the assigned display resets.
corresponding Setpoint output (
output logic setting (normal or reverse).
Timer stops when the Setpoint output activates (
Stopping the Timer as a result of this parameter does not constitute a
When the Setpoint output activates (
When
This parameter controls the illumination of the LED annunciator for the
Determines the on/off state of the Setpoint output at power-up. Regardless of
)
if the output should not affect the Timer Run/Stop status.
OUTPUT RESET WITH DISPLAY RESET
is selected, the Setpoint output will reset when the Setpoint
)
) –
) –
Deactivates the Setpoint output at power-up
Activates the Setpoint output at power-up
Restores the output to the state it was in prior to power-down
TIMER/COUNTER AUTO RESET
SETPOINT POWER-UP STATE
Annunciator and display flashes when output is “on” (activated)
Annunciator displayed when output is “on” (activated)
Annunciator displayed when output is “off” (deactivated)
Annunciator disabled
SETPOINT ANNUNCIATOR
) resets. Select
TIMER STOP
) as follows:
) or deactivates (
if the Setpoint output should not
) or deactivates (
). Select
), the meter
if the
).

Related parts for PAXCK010