K33L1A Omron, K33L1A Datasheet

OPTION BOARD, SENSOR, PS+4-20MA

K33L1A

Manufacturer Part Number
K33L1A
Description
OPTION BOARD, SENSOR, PS+4-20MA
Manufacturer
Omron
Datasheet

Specifications of K33L1A

Accessory Type
Sensor Power Supply / Output Board
Voltage Rating
12VDC
Current Rating
80mA
Svhc
No SVHC (15-Dec-2010)
For Use With
K3HB-R Rotary Pulse Indicator, K3HB-P Timer Interval Indicator
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
• Easy recognition of judgment results using two-color
• Equipped with a position meter for monitoring
• External event inputs allows using various
• Series expanded to include DeviceNet models.
• Short body with depth of only 95 mm (see note)
• UL certification (Certification Mark License).
• CE Marking conformance by third party assessment
• Water-resistant enclosure conforms to NEMA 4X
Note: Depth of 97 mm for DeviceNet models.
The K3HB Series has been made complete with
the addition of Digital Signal Input Models.
Features
Red-Green Display Allows Easy
Recognition of Judgment Results
The measurement value display can be set to switch between red
and green in accordance with the status of comparative outputs. This
means that the status can be easily seen at a distance.
Position Meter Enables Easy Monitoring of
Operating Status Trends
The present value with respect to the measurement or display range
(full scale) can be viewed on a bar display. The operating status can
be grasped intuitively, allowing easy judgment of levels and threshold
values.
Note: This function is different from the single-LED display of the K3HB-C.
Short Body with Depth of Only 95 mm
(from Behind the Front Panel)
A short body of only 95 mm (see note) contributes to the
development of slimmer and smaller control panels and installations.
Note: Depth of DeviceNet models is 97 mm.
display that can be switched between red and green.
operating status trends.
measurement and discrimination applications.
(from behind the front panel).
body.
(equivalent to IP66).
Digital Indicators
K3HB Series (Pulse Input Series)
(The depth is 100 mm when mounted to the terminal cover.)
Refer to Common Precautions on page 30.
MAX/MIN
HH
LL
Depth:
H
P
L
Max
B
Min
L
95 mm
CMW
Hold
LEVEL
T
(See note.)
MODE
HH
LL
H
L
SHIFT
UP
Digital Indicators
than earlier
shorter
models
27%
Position meter
K3HB Series (Pulse Input Series)
50 kHz High-speed Pulse Measurement
(K3HB-R)
Supports high-speed pulse measurement (up to 50 kHz) of rotary
encoders or any ON/OFF pulse signal, which enables rotational
measurement of objects rotating at high speeds.
Note: No-voltage contacts of up to 30 Hz are supported.
Measurement of Wide Range of Pulse
Interval Times (K3HB-P)
Measures and displays the results of the pulse interval between two
points. The pulse interval measurement range is broad, from 10 ms
to 3,200 s.
High-speed Up/Down Counting Pulse
Measurement (K3HB-C)
Perfect for high-speed measurement of rotary encoders or any
ON/OFF pulse signals. Cumulative pulse input is 50 kHz, quadrature
pulse inputs are 25 kHz, and up/down pulse inputs are 30 kHz.
Note: No-voltage contacts of up to 30 Hz are supported.
10 ms to 3200 s
50 kHz
50 kHz
1

Related parts for K33L1A

K33L1A Summary of contents

Page 1

Digital Indicators K3HB Series (Pulse Input Series) The K3HB Series has been made complete with the addition of Digital Signal Input Models. • Easy recognition of judgment results using two-color display that can be switched between red and green. • ...

Page 2

... Digital Indicators are used in a wide variety of applications, from an electronic measurement value display or equipment/device operating status display to a host communications interface in monitoring and control systems. OMRON provides a complete lineup for a variety of input and control output applications to meet all your application requirements. ...

Page 3

... For applications that require safety, ensure that there is sufficient leeway in ratings and performances, install fail-safe measures, and take any other safety measures required by the application. In addition, contact your nearest OMRON representative and confirm specifications. K3HB-series Product Lineup ■ ...

Page 4

Rotary Pulse Indicator K3HB-R Digital Rotary Pulse Meter Capable of 50 kHz Measurements • Measures High-speed Pulses at 50 kHz. Provides high-speed pulse measurements kHz of rotary encoder or ON/OFF pulse signals and can perform rotating measurement ...

Page 5

... HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.) Note power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended. ...

Page 6

Characteristics Display range 19,999 to 99,999 Measurement accuracy Functions F1, F6: ±0.006% rgd ±1 digit (for voltage pulse/open collector sensors) (at 23±5 C) Functions F2 to F5: ±0.02% rgd ±1 digit (for voltage pulse/open collector sensors) Measurement range Functions ...

Page 7

Operation ■ Functions (Operating Modes Functions provide rpm/circumferential speed and other calculation displays by measuring continuous pulses (frequencies). Example Length of processing stage Function name Function No. f1 Rpm/circumferential speed f2 Absolute ratio f3 ...

Page 8

Function Operation F2 Multiples input B divided by input 100 and Absolute displays the ratio as a percentage (%). ratio Display unit Multiplies the error between input A and input B Error ratio B ...

Page 9

What Is Prescaling? To make calculations using the input pulse to display rotation (rpm) or circumferential speed, the number of pulses per rotation or the length of the circumference must be multiplied by a certain coefficient. This coefficient is ...

Page 10

Timer Interval Indicator K3HB-P Digital Time Interval Meter for Measuring Passing Speed, Time, or Cycle between Two Points. • Measures Wide Range of Pulse Interval Times Measures, calculates, and displays pulse intervals between two points. Wide range for pulse interval ...

Page 11

... HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.) Note power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended. ...

Page 12

Characteristics Display range 19,999 to 99,999 Measurement accuracy ±0.08% rgd ±1 digit (for voltage pulse/open collector sensors) (at 23±5 C) Measurement range Functions F1, F3, and F4: 3,200 s Function F2: Functions F5 and F6: Input signals ...

Page 13

Operation ■ Functions (Operating Modes These functions use the internal system clock to measure the time between pulses or the pulse ON time and then display time measurements or a variety of other calculations. Function name Function ...

Page 14

Function Operation F4 Displays input A ON time (T). Time band Input HOLD input Display Measurement range 3,200 s • Recovery time (TR required before starting ...

Page 15

Up/Down Counting Pulse Indicator K3HB-C Measure High-speed Up/down Pulses with this Up/down Pulse Meter. • Perfect for Measuring Rotary Encoder and ON/OFF Pulse Signals at High Speed Cumulative pulse input is 50 kHz, quadrature pulse inputs are 25 kHz, and ...

Page 16

... HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.) Note power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended. ...

Page 17

Characteristics Display range 19,999 to 99,999 Measurement range Functions F1, F2: ±2 gigacounts Functions F3 Input signals • No-voltage contact (30 Hz max. with ON/OFF pulse width min.) • Voltage pulse • Open collector Connectable sensors ...

Page 18

Operation ■ Functions (Operating Modes Function name Function No. f1 Individual inputs Phase differential inputs f2 f3 Pulse counting input Function Operation F1 Counts input A as incremental pulses and input B as Individual decremental pulses. The ...

Page 19

What Is Prescaling? Prescaling converts the count value to any numeric value. To display @@@@.@ system that outputs 250 pulses for a 0.5-m feed, the length per pulse = 500 mm (0 The prescale ...

Page 20

Common Specifications ■ Event Input Ratings K3HB-R S-TMR, HOLD, RESET, BANK1, BANK2, BANK4 K3HB-P/-C HOLD, RESET, BANK1, BANK2, BANK4 Contact ON max., OFF: 100 k min. No-contact ON residual voltage max. OFF leakage current: 0.1 mA ...

Page 21

DeviceNet Communications Communications protocol Supported Remote I/O communications communications I/O allocations Message communications Connection methods Baud rate Communications media Communications distance Communications power supply Allowable voltage fluctuation range Current consumption Maximum number of nodes Maximum number of slaves Error control ...

Page 22

... Sensor 12 VDC 12 VDC power (HONDA TSUSHIN KOGYO CO., LTD supply Special Cable (Sold separately) K32-BCD (OMRON) <L2A> <L1A> (HDR-E50MAG1 with 0.3-m cable) Sensor power supply B1 The BCD COMMON is shared. The pins indicated in the above diagram B2 as blank (white) boxes have been removed. ...

Page 23

... BANK1 10: COM Applicable Connector (Sold separately) XG4M-1030 (OMRON) Special Cable (Sold separately) K32-DICN (OMRON) (XG4M-1030 with 3-m cable) The following signals depend on the model: S-TMR: Used by the K3HB-R only. COMPENSATION: Used by the K3HB-C only. Shape Connected device end (PLC, display device, etc.) 300 mm 46 ...

Page 24

Derating Curve for Sensor Power Supply (Reference Values) For 12V 140 1 120 100 Ambient temperature ( C) Note: 1. The above values were obtained under ...

Page 25

... Refer to the following User's Manual for application precautions and other information required when using the Digital Indicator: K3HB-R/P/C Digital Indicator User's Manual (Cat. No. N136) The manual can be downloaded from the following site in PDF format: OMRON Industrial Web http://www.fa.omron.co.jp Continuous Data Output REQ ...

Page 26

Component Names and Functions Max./Min. status indicator Turns ON when the maximum value or minimum value is displayed in the RUN level. Level/bank display In RUN level, displays the bank if the bank function is ON. (Turns OFF if ...

Page 27

... Waterproof Packing The waterproof packing ensures a level of waterproofing that conforms to NEMA 4X. Depending on the operating environment, deterioration, contraction, or hardening may occur and replacement may be necessary. In this case, consult your OMRON representative. Digital Indicators Panel Cutout Dimensions SV display 120 min. 4.9 3 ...

Page 28

Main Functions ■ Main Functions and Features Measurement func Function The K3HB-R has the following six functions for receiving and displaying input pulses. F1: Rotation (rpm)/circumferential speed F2: Absolute ratio F3: Error ratio F4: Rotational difference F5: ...

Page 29

Outputs out Comparative Output Pattern Standard, zone, and level comparative output patterns can be selected for comparative outputs. hys R Hysteresis Prevents comparative outputs from chattering when the measurement value fluctuates slightly near the set value. o-stp ...

Page 30

Common Precautions ■ Precautions !WARNING Do not touch the terminals while power is being supplied. Doing so may possibly result in electric shock. Make sure that the terminal cover is installed before using the product. Always provide protective circuits in ...

Page 31

DeviceNet communications cables with excessive force or bend them past their natural bending radius. 21.Do not connect or remove connectors while the DeviceNet power is being supplied. Doing so will cause product failure or malfunction. 22.Use ...

Page 32

... Warranty and Limitations of Liability ■ WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE ...