4.4.2 General
The interface IF-A1 is an analogue interface with galvani-
cally isolated, customisable, analogue and digital inputs and
outputs. Visualisation:
Customisable means, that you can customise these inputs
and outputs to your needs, but always within a voltage ran-
ge of 0...10V. At devices with two extension card slots (eg.
PSI9000) it is possible to combine the IF-A1 with a digital
interface card (eg. IF-U1 (USB)), in order to control, for ex-
ample, the device by USB and put out actual values via the
analogue outputs of the analogue card. Or vice versa, you
control the device by analogue set values and read out and
log the actual values to a PC via RS3, CAN or USB.
Generally applies: all monitoring and surveillance features
are permanently active, even if two card (one digital, one
analogue) are equipped. Only the control of the device with
set values requires the activation of the external mode (IF-
A1) resp. of the remote mode (digital interfaces), whereas
the remote mode (control by a digital interface card)
has priority. In case the device is in control by the analogue
interface (external mode, indicated in the display by
tern) and the control of the device via a digital interface is
activated, the device will switch to remote mode (indicated
in the display by
4.4.3 Configuring the IF-A1
The interface is configured in the communication menu:
Here you can see an overview of the equipped cards.
With:
the analogue interface card is selected for configuration.
Following parameters can be set:
Analogue inputs
Analogue set values are only accepted by the device if it is
in external mode (indicated in the display by
The analogue interface IF-A1 has three analogue inputs
with these features:
AI1: PSEL (external set value for power) or RSEL (external
Slot A : { IF-… }
Slot B : { IF-… }
Slot {A|B}: IF-A1 +
M
set value for inner resistance, optional with unlocked
U/I/R operation)
Netzgeräteseite
+
PSU side
Communication +
remote).
Name of 1st interface card (if equipped)
Name of nd interface card (if equipped)
IF-A1
Ein/Ausgänge
In/Out
extern).
ex-
AI: CSEL (external set value for current)
AI3: VSEL (external set value for voltage)
The minimum and maximum input voltage can be preset.
The analogue inputs can be adapted the input signal this
way. By limitting the standard voltage range of 0...10V to
a lower value the resolution is also lowered. Example: if
the voltage range is set to 1V difference between U
U
10.
The first value stands for U
second for U
U
U
The adjusted voltage range, for example .00V...8.00V, cor-
responds to 0...100% set value. A higher or lower voltage is
treated as either U
AI1
Rsel is only available if U/I/R mode is unlocked.
AI2
AI3
Analogue outputs
The actual values of output voltage, current and power are
led out to the analogue outputs. These outputs can be ad-
apted to custom requirements. The first value stands for U
(minimum output voltage), the second for U
output voltage). It applies:
U
U
By limitting the standard voltage range of 0...10V to a lower
value the resolution is also lowered. Example: if the voltage
range is set to 1V difference between U
and accuracy will be reduced by the factor 10.
The reference voltage is an exception. It can be set to a
value between 1V and 10V.
AO0
AO1
AO2
AO3
= {Psel | Rsel}
= Vsel
= Csel
= Vref
= Vmon
= Cmon
= Pmon
min
min
max
min
max
, resolution and accuracy will be reduced by the factor
=
=
=
=
{ 0.00V...4.00V }
{ 0.00V...9.00V }
{ 4.00V...10.00V }
{ 4.00V...10.00V }
external set value for voltage
external set value for current
max
Adjustable reference voltage in a range of
{1V...10V}.
Monitor (actual value)
Monitor (actual value)
Monitor (actual value)
(maximum input voltage). It applies:
external set value for power/resistance
min
or U
wobei gilt: U
max
Default:
Default:
Default:
Default:
Default:
Default:
Default:
min
.
(minimum input voltage), the
Psel 0.00 10.00V
0.00 10.00V
0.00 10.00V
10.00V
0.00V 10.00V
0.00V 10.00V
0.00V 10.00V
output voltage
output current
output power
max
max
and U
> U
min
max
min
(maximum
, resolution
max
EN
and
min
61