FA1-B0-16-917-32A-BG Carling Technologies, FA1-B0-16-917-32A-BG Datasheet

CIRCUIT BREAKER, HYD-MAG, 1P, 125V, 175A

FA1-B0-16-917-32A-BG

Manufacturer Part Number
FA1-B0-16-917-32A-BG
Description
CIRCUIT BREAKER, HYD-MAG, 1P, 125V, 175A
Manufacturer
Carling Technologies
Series
Fr
Datasheet

Specifications of FA1-B0-16-917-32A-BG

No. Of Poles
1
Current Rating
175A
Interrupting Capacity
50kA
Dielectric Strength
1.96kV
Trip Time
150s
Voltage Rating Vdc
125V
Trip Time Max
150sec
Trip Time Min
22sec
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
110
F-Series – General Specifications
Agency Certifications
UL Listed
UL Standard 489A
Electrical
Table A:
capabilities as a Molded Case Circuit Breaker
Table B:
(Guide DITT, File E189195), under UL489A
Table A: Lists UL Listed (489)and CSA Certified (C22.2 N0. 5.1-M) configurations and performance
Lists UL Listed configurations and performance capabilities as Circuit Breakers for use in Communications Equipment
Circuit Breakers, Molded Case,
(Guide DIVQ7, File E129899), UL
Standard 489;
Complies with the requirements of
CSA Standard for Molded Case
Circuit Breakers, CAN/CSA - C22.2
No. 5.1 - M
TUV Certified
F-Series breakers are available up to 700A, and are also
available with a 25 millivolt metering shunt construction. This
optional construction provides a safe method for monitoring
current flowing through the breaker by simply connecting a
meter with light gauge wire to the appropriate terminals locat-
ed on the shunt housing at the rear of the breaker. You can
customize the application by measuring and displaying per-
centage of current, watts or safe/danger zones.
EN60947-2
Low Voltage Switchgear and Control
Gear under License No. R72031058
www.carlingtech.com

Related parts for FA1-B0-16-917-32A-BG

FA1-B0-16-917-32A-BG Summary of contents

Page 1

F-Series – General Specifications Agency Certifications UL Listed UL Standard 489A Circuit Breakers, Molded Case, (Guide DIVQ7, File E129899), UL Standard 489; Complies with the requirements of CSA Standard for Molded Case Circuit Breakers, CAN/CSA - C22.2 No. 5.1 - ...

Page 2

Electrical Maximum Voltage 125VDC Current Ratings Standard current coils: 100, 125, 150, 175, 225, 250 amps. 300, 350, 400, 500, 600, 700 amps available as parallel pole construction. Auxiliary Switch Rating SPDT; 10.1 Amps @ 250VAC, 1.0 Amps @ 65VDC, ...

Page 3

F-Series Handle – Ordering Scheme – Series Poles Circuit Actuator Auxiliary/ Alarm Switch 1 SERIES F 2 ACTUATOR A Handle, one per pole S Mid-Trip Handle, one per pole T ...

Page 4

Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com F-Series Handle – Circuit & Terminal Diagrams 113 ...

Page 5

F-Series Handle – Circuit & Terminal Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 114 www.carlingtech.com ...

Page 6

Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com F-Series Handle – Circuit & Terminal Diagrams 115 ...

Page 7

F-Series Handle – Form & Fit Diagrams Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. 116 www.carlingtech.com ...

Page 8

Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com F-Series Handle – Form & Fit Diagrams 117 ...

Page 9

F-Series Handle – Form & Fit Diagrams F-Series breakers are available up to 700A, and are also available with a 25 millivolt metering shunt construction. This optional construction provides a safe method for monitoring current flowing through the breaker by ...

Page 10

Notes: 1 All dimensions are in inches [millimeters]. 2 Tolerance ±.020 [.51] unless otherwise specified. www.carlingtech.com F-Series Handle – Form & Fit Diagrams 119 ...

Related keywords