3RV10111KA10 SIEMENS, 3RV10111KA10 Datasheet - Page 47

CIRCUIT BREAKER, 9-12A

3RV10111KA10

Manufacturer Part Number
3RV10111KA10
Description
CIRCUIT BREAKER, 9-12A
Manufacturer
SIEMENS
Series
3RVr
Datasheet

Specifications of 3RV10111KA10

No. Of Poles
3
Voltage Rating Vac
690V
Mounting Type
DIN Rail (EN 50022)
Approval Bodies
UL, CSA, VDE
Breaking Capacity Current Ac
50kA
Current Max
12.0A
Current Min
9.00A
3RB22/3RB23 solid-state overload relays for full motor protection with screw connection or spring-loaded terminals
for stand-alone installation, CLASS 5, 10, 20 and 30 adjustable
Features and technical specifications:
• Overload protection, phase failure protection and unbalance
• External power supply 24 ... 240 V AC/DC
• Auxiliary contacts 2 NO +2 NC
• Manual and automatic RESET
• Electrical remote RESET integrated
• 4 LEDs for operating and status displays
1) The analog signal 4 ... 20 mA DC can be used for operating rotary coil
2) The following information on ground fault protection refers to sinusoidal
* You can order this quantity or a multiple thereof.
3RB2. 83-4AA1
3RB2. 83-4AC1
Evaluation modules
Function expansion modules
protection
instruments or for feeding into analog inputs of programmable logic
controllers.
residual currents at 50/60 Hz:
- With a motor current of between 0.3 and 2 times the set current
- With a motor current of between 2 and 8 times the set current
- The trip delay amounts to between 0.5 and 1 second.
will trip at a ground fault current equal to 30% of the set current.
will trip at a ground fault current equal to 15% of the set current.
Size
Contactor
S00 ... S12 Monostable
Version
Bistable
Analog Basic 1 module
Analog output DC 4 ... 20 mA,
with overload warning
Analog Basic 1 GF module
Analog output DC 4 ... 20 mA,
with internal ground fault
detection and overload warning
Analog Basic 2 GF module
Analog output DC 4 ... 20 mA,
with internal ground fault
detection and ground fault
signaling
Basic 1 GF module
with internal ground fault
detection and overload warning
Basic 2 GF module
with internal ground fault
detection and ground fault
signaling
2)
2)
1)
1)2)
1)2)
I
I
e
e
the unit
the unit
Connection
type
connection
Spring-
loaded
terminals
Screw
connection
Spring-
loaded
terminals
Screw
• TEST function and self-monitoring
• Internal ground fault detection with function expansion
• Screw connection or spring-loaded terminals for auxiliary,
• Input for PTC sensor circuit
• Analog output with function expansion module
DT Order No.
}
A
}
A
}
}
}
}
}
module
control and sensor circuits
3RB22 83-4AA1
3RB22 83-4AC1
3RB23 83-4AA1
3RB23 83-4AC1
3RB29 85-2AA0
3RB29 85-2AA1
3RB29 85-2AB1
3RB29 85-2CA1
3RB29 85-2CB1
3RB22, 3RB23 for high-feature applications
3RB2 Solid-State Overload Relays
Price
per PU
Overload Relays
PU
(UNIT,
SET, M)
Siemens LV 1 · 2006
1
1
1
1
1
1
1
1
1
PS*
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
PG
101
101
101
101
101
101
101
101
101
Weight
per PU
approx.
kg
5/47
0.300
0.300
0.300
0.300
0.030
0.030
0.030
0.030
0.030

Related parts for 3RV10111KA10