6MBI50U4A-120-50 FUJI ELECTRIC, 6MBI50U4A-120-50 Datasheet - Page 8

no-image

6MBI50U4A-120-50

Manufacturer Part Number
6MBI50U4A-120-50
Description
6-PACK IGBT MODULE 50A 1200V TRENCH
Manufacturer
FUJI ELECTRIC
Datasheet

Specifications of 6MBI50U4A-120-50

Module Configuration
Six
Transistor Polarity
N Channel
Dc Collector Current
75A
Collector Emitter Voltage Vces
2.35V
Power Dissipation Max
275W
Collector Emitter Voltage V(br)ceo
1.2kV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
6MBI50U4A-120-50
Manufacturer:
SANKEN
Quantity:
1 463
Test
cate-
gories
1 High temperature
2 High temperature
3 Temperature
4 Intermitted
(for Collector-Emitter)
Humidity Bias
(Power cycle)
( for IGBT )
Reverse Bias
Bias (for gate)
Operating Life
Test items
Electrical
Visual
Note : Each parameter measurement read-outs shall be made after stabilizing the components
characteristic
inspection
Item
at room ambient for 2 hours minimum, 24 hours maximum after removal from the tests.
at room ambient for 2 hours minimum, 24 hours maximum after removal from the tests.
And in case of the wetting tests, for example, moisture resistance tests, each component
And in case of the wetting tests, for example, moisture resistance tests, each component
shall be made wipe or dry completely before the measurement.
shall be made wipe or dry completely before the measurement.
Each parameter measurement read-outs shall be made after stabilizing the components
Leakage current
Gate threshold voltage VGE(th)
Saturation voltage
Forward voltage
Thermal
Isolation voltage
Visual inspection
Test temp.
Bias Voltage
Bias Method
Test duration
Test temp.
Bias Voltage
Bias Method
Test duration
Test temp.
Relative humidity
Bias Voltage
Bias Method
Test duration
ON time
OFF time
Test temp.
Number of cycles
resistance
Peeling
Plating
and the others
Characteristic
IGBT
FWD
Test methods and conditions
Reliability Test Items
: Ta = 125±5 ℃
: VC = 0.8×VCES
: Applied DC voltage to C-E
: 1000hr.
: Ta = 125±5 ℃
: VC = VGE = +20V or -20V
: Applied DC voltage to G-E
: 1000hr.
: 85±2
: 85±5%
: VC = 0.8×VCES
: Applied DC voltage to C-E
: 1000hr.
: 2 sec.
: 18 sec.
:
: 15000 cycles
Failure Criteria
VGE = 0V
VCE = 0V
VGE = 0V
Tj ≦ 150 ℃, Ta=25±5 ℃
VCE(sat)
or
Symbol
±IGES
(Tj ≦ 150 ℃)
(Tj ≦ 150 ℃)
Tj=100±5 deg
ICES
Viso
VF
VGE
VF
-
VCE
o
C
Lower limit Upper limit
LSL×0.8
The visual sample
Broken insulation
Failure criteria
-
-
-
-
-
-
LSL : Lower specified limit.
USL : Upper specified limit.
USL×1.2
USL×1.2
USL×1.2
USL×1.2
USL×1.2
USL×2
USL×2
MS5F 6201
Unit
mA
mA
mV
mV
V
V
-
-
A
Reference norms
(Aug.-2001 edition)
Condition code C
Test Method 101
Test Method 101
Test Method 102
Test Method 106
EIAJ ED-4701
Note
Number
sample
of
5
5
5
5
H04-004-03a
8
14
Accept-
ance
number
( 0 : 1 )
( 0 : 1 )
( 0 : 1 )
( 0 : 1 )
a

Related parts for 6MBI50U4A-120-50