SLW360 TIMEGUARD, SLW360 Datasheet - Page 5

PIR, 360 DEG, SURFACE MOUNT, CEILING

SLW360

Manufacturer Part Number
SLW360
Description
PIR, 360 DEG, SURFACE MOUNT, CEILING
Manufacturer
TIMEGUARD
Datasheet

Specifications of SLW360

Beam Angle
360°
Length
53mm
Depth
103mm
Colour
White
External Width
103mm
Contact Voltage Ac Max
230V
Frequency
50Hz
Mounting Type
Surface Mount
Range
6m
Svhc
No SVHC (15-Dec-2010)
Rohs Compliant
NA
Lead Free Status / RoHS Status
na
4
Installation
After choosing a suitable location (see previous section)
install the unit as follows:
The unit is suitable for connection to a 230 V ac 50Hz
electricity supply. It is suggested that 3-core round
flexible cable of 1 sq. mm gauge is used. An internal
switch should be installed to switch the power to the
unit ON & OFF. This allows the sensor to be easily
switched off when not required or for maintenance
purposes.
Remove the top cover of the sensor by twisting the top
cover anticlockwise until the arrows shown on diagram
E are aligned.The top cover can now be removed from
the sensor body.
Mark the position of the fitting holes. See diagram G.
Drill the holes. Insert the rawl plugs into the holes.
The sensor is more sensitive to movement ACROSS its
field of vision than to movement directly TOWARDS
(see diagram B). Therefore position the unit so that the
sensor looks ACROSS the likely approach path.
Avoid positioning the sensor where there are any
sources of heat in the detection area (extractor fans,
tumble dryer exhausts etc.) including opposite any
other light sources such as other security lights.
Reflective surfaces (ie pools of water or white-painted
walls) and overhanging branches may cause false
activation under extreme conditions.
During extreme weather conditions the motion sensor
may exhibit unusual behaviour. This does not indicate
a fault with the sensor. Once normal weather conditions
return, the sensor will resume normal operation.
the circuit breaker before proceeding with the installation.
Switch off the electricity at the fuse box by removing the
All fittings should be installed by competent person in
accordance with IEE Wiring Regulations (BS7671)
relevant fuse or switching off
IMPORTANT