460-480 Tyco Electronics, 460-480 Datasheet - Page 116

Voltage Transformer

460-480

Manufacturer Part Number
460-480
Description
Voltage Transformer
Manufacturer
Tyco Electronics
Series
460r
Datasheet

Specifications of 460-480

Turns Ratio
4
Transformer Mounting
Chassis
Voltage Ratio
480
Primary Voltages
480V
Power Rating
150VA
Output Voltage
120V
Mounting Type
Foot Mounted
Transformer Type
Voltage
Lead Free Status / RoHS Status
na
Frequency:
60Hz
Standard Secondary Voltage:
120 Volts Line
Insulation Level:
600 Volts, 10kV BIL full wave
Accuracy Class:
0.3 W, X, M & Y 1.2Z
@0.3 W, 0.6 X, M & Y
Thermal Rating:
750VA at 30°C amb
500VA at 55°C amb
CSA 223647
VOLTAGE TRANSFORMER CIRCLE DIAGRAM
THIS GRAPH IS DRAWN FOR 60Hz P.F. SYSTEM LOAD
Approvals
116
UL 257877
Model 450
• The primary and secondary terminals are No. 10–32 screws into 3/8” deep brass inserts and
• The core and coil assembly is encased in a thermoplastic shell and filled with resin.
• These transformers are designed for operation line-to-line. They may also be operated
• It is desirable to use an 8.0 amp BBS type or equal fuse in the secondary to protect
• With two exceptions these transformers are ANSI C57.13 group 1. Those marked * are
• Model designed specifically for 50Hz operation are available with reduced performance –
• Fuse blocks containing type KTK–R (class CC) fuses can be fitted.
• When primary fuses are requested, the ratings will be as given in the table below.
• This page contains a circle diagram for the estimation of the errors for other than rated
• When only one fuse is used, it must be connected into the line side (H1) terminal wiring.
• Approximate weight: 25 lbs
Retro Fit Fuse Kit Order No. 0222 PL 7019
fitted with one lockwasher and flatwasher and are contained in a sealable terminal cover.
line-to-ground or line-to-neutral at reduced voltage, (58% of rated volts).
the transformer.
group 2.
consult factory for details.
burdens. See page 9 in this section for a description of its use.
This will prevent the presence of voltage at the H1 terminal for a ruptured fuse in the
neutral (H2) terminal wiring for line-to-neutral connected transformers.
@450–069
@450–120
Not
Fused
*450–480
*450–600
450–208
450–240
450–277
450–288
450–300
450–346
Catalogue Numbers
*450–480F
*450–600F
Primary
Fuses Only
450–069F
450–120F
450–208F
450–240F
450–277F
450–288F
450–300F
450–346F
*450–480FF
*450–600FF
450–069FF
450–120FF
450–208FF
450–240FF
450–277FF
450–288FF
450–300FF
450–346FF
Primary &
Secondary
Fuses
*480:120
*600:120
Rating
69.3:120
300:120
Voltage
208:120
240:120
346:120
288:120
277:120
120:120
Turns
Ratio
0.58:1
2.88:1
1.73:1
2.31:1
2.4:1
2.5:1
4:1
2:1
5:1
1:1
Rec. Primary
Fuse Rating
10.0
15.0
8.0
8.0
8.0
6.0
6.0
4.0
5.0
3.0