50664 EMIT, 50664 Datasheet - Page 4

Air Ionizer

50664

Manufacturer Part Number
50664
Description
Air Ionizer
Manufacturer
EMIT
Datasheet

Specifications of 50664

Ionizer Type
Overhead
Flow Rate Max
100CFM
Depth
3.5"
Width
6.5"
Height
42"
Supply Voltage Vac
115V
Peak Reflow Compatible (260 C)
No
Flow Rate
100CFM
External Width
6.50"
Supply Voltage
110V
External Depth
3.50"
External Height
42.00"
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
B A L 1
B A L 2
B A L 3
S A V E
O n
To change the three digit network address and enable or disable the remote control, use the
following procedure. Note: Address can only be 000 to 254. If an invalid address is selected
the display will blink, the buzzer will sound three times, and the unit will not continue to other
menus until a valid address has been selected.
1 2 3
1 2 4 A
1 5 4 A
TB-6534 Page 4 of 8
S P d 5
b
address.
Place the charge plate monitor under the left fan (fan 1). Press and hold the
button (negative), or the
zero. For finer adjustment, use single clicks of the buttons. Press the
to go to the next fan. By pressing the
fan or menu.
Move the charge plate monitor under the middle fan (fan 2). Press
buttons to adjust the balance under fan 2 to zero. Press the
the next fan, or press the
Move the charge plate monitor under the right fan (fan 3). Press
to adjust the balance under fan 3 to zero. Re-check each fan and repeat Bal 1,
BAL2, and BAL3 adjustments as necessary to eliminate the effect of airflow
interference between the fans. Press the
To save and exit at any time during the setup mode press
simultaneously. The 50665 will save all settings and return to normal
operation. The 50665 will display “SAVE” and the status of the buttons (“On b,”
meaning that the buttons are enabled), then the unit address.
(Note: the control buttons can be disabled, “OFF b”, by the ZVI-IR remote
control only.)
Press
The unit will display “Prog” momentarily and go to the “fan speed” menu. Press
the
The last digit of the address will be flashing. Press
the last digit (0 to 9). Press the
The second digit of the address should now be flashing. Press
to change the second digit (0 to 9). Press the
digit of the address.
button to go back to the “address” menu.
and
buttons simultaneously to go into the ionizer setup mode.
button, (positive), to adjust the balance under fan 1 to
button to go to previous menu.
button to go to the second digit of the
button you can go back to the previous
button to go to the next menu.
button to change the first
or
buttons to change
and
button to go to
Revision July 2008