50664 EMIT, 50664 Datasheet - Page 6

Air Ionizer

50664

Manufacturer Part Number
50664
Description
Air Ionizer
Manufacturer
EMIT
Datasheet

Specifications of 50664

Ionizer Type
Overhead
Flow Rate Max
100CFM
Depth
3.5"
Width
6.5"
Height
42"
Supply Voltage Vac
115V
Peak Reflow Compatible (260 C)
No
Flow Rate
100CFM
External Width
6.50"
Supply Voltage
110V
External Depth
3.50"
External Height
42.00"
Leaded Process Compatible
No
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
The figures below show the jumper (JH2) configuration for 120 and 220 VAC settings. (Note:
the AC power cord MUST always be disconnected before the unit is disassembled.)
the six screws along the top of the unit with a Phillips screwdriver. Once the lid is removed the
three fan modules are easily accessible. To remove a fan module disconnect the ribbon cable
connector from the socket and lift the fan module out. The eight emitter points can be easily
cleaned using Semtronics part number S204-200 emitter point cleaner, or 99% rubbing alcohol
and a clean brush. To clean any excess dirt off of the fan and or fan guard it is recommended
to use compressed air. Once the fan modules are clean slide them back onto the alignment
posts, connect the ribbon cable, and replace the lid.
Neutralization (Decay) Times
Note: Reference ESD STM 3.1-2000. The distance from the ionizer to the charge plate is 18”.
(Readings are typical and taken at maximum fan speed.)
TB-6534 Page 6 of 8
The AC input voltage can be verified or changed by removing the top cover of the unit.
To clean the ionizer first turn off and unplug the unit. Remove the top lid by removing
+ 32.7
- 28.6
+19.2
+20.7
- 26.5
-19.3
12”
12”
16”
120VAC
fan #1
+ 10.2
- 12.1
+ 3.5
+ 1.8
- 4.2
- 2.4
15”
fan #2
+ 3.3
+ 1.9
+ 4.8
- 5.1
- 4.3
- 2.9
15”
220VA
fan #3
+ 4.0
+ 1.9
+ 6.4
- 5.9
- 3.1
- 9.7
16”
Revision July 2008
© 2008 DESCO INDUSTRIES INC.
+ 16.7
- 25.4
+ 14.3
- 16.4
+ 9.9
-17.0
Employee Owned