Specifications of AD9276-80KITZ

Silicon Manufacturer
Analog Devices
Application Sub Type
ADC
Kit Application Type
Data Converter
Silicon Core Number
AD9276
Number Of Adc's
1
Number Of Bits
12
Sampling Rate (per Second)
80M
Data Interface
Serial, SPI™
Inputs Per Adc
1 Differential
Input Range
*
Power (typ) @ Conditions
195mW @ 40MSPS
Voltage Supply Source
Analog and Digital
Operating Temperature
-40°C ~ 85°C
Utilized Ic / Part
AD9276
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
MEMORY MAP
READING THE MEMORY MAP TABLE
Each row in the memory map register table has eight bit loca-
tions. The memory map is roughly divided into three sections:
the chip configuration register map (Address 0x00 to Address 0x02),
the device index and transfer register map (Address 0x04 to
Address 0xFF), and the program register map (Address 0x08
to Address 0x2D).
The leftmost column of the memory map indicates the register
address, and the default value is shown in the second rightmost
column. The Bit 7 (MSB) column is the start of the default
hexadecimal value given. For example, Address 0x09, the clock
register, has a default value of 0x01, meaning that Bit 7 = 0, Bit 6 =
0, Bit 5 = 0, Bit 4 = 0, Bit 3 = 0, Bit 2 = 0, Bit 1 = 0, and Bit 0 = 1,
or 0000 0001 in binary. This setting is the default for the duty
cycle stabilizer in the on condition. By writing a 0 to Bit 0 of this
address, followed by 0x01 in Register 0xFF (the transfer bit), the
duty cycle stabilizer is turned off. It is important to follow each
writing sequence with a transfer bit to update the SPI registers.
Rev. 0 | Page 41 of 48
All registers except Register 0x00, Register 0x02, Register 0x04,
Register 0x05, and Register 0xFF are buffered with a master
slave latch and require writing to the transfer bit. For more
information on this and other functions, consult the AN-877
Application Note, Interfacing to High Speed ADCs via SPI.
RESERVED LOCATIONS
Undefined memory locations should not be written to except
when writing the default values suggested in this data sheet.
Addresses that have values marked as 0 should be considered
reserved and have a 0 written into their registers during power-up.
DEFAULT VALUES
After a reset, critical registers are automatically loaded with
default values. These values are indicated in Table 18, where
an X refers to an undefined feature.
LOGIC LEVELS
An explanation of various registers follows: “bit is set” is
synonymous with “bit is set to Logic 1” or “writing Logic 1 for
the bit. ” Similarly, “bit is cleared” is synonymous with “bit is set
to Logic 0” or “writing Logic 0 for the bit. ”