NJU6535FH1 NJR, NJU6535FH1 Datasheet

LCD Drivers 1/3 1/4 LCD

NJU6535FH1

Manufacturer Part Number
NJU6535FH1
Description
LCD Drivers 1/3 1/4 LCD
Manufacturer
NJR
Datasheet

Specifications of NJU6535FH1

Operating Supply Voltage
5.5 V
Maximum Operating Temperature
+ 70 C
Package / Case
PQFP-H1
Minimum Operating Temperature
0 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NJU6535FH1
Manufacturer:
JRC
Quantity:
8 861
Part Number:
NJU6535FH1
Manufacturer:
JRC
Quantity:
1 000
!
!
#
#
#
#
#
#
#
#
#
#
#
#
#
#
#
Ver.2004-04-16
segment type LCD panel with key scan function
transmitting the 30 keys maximum scanned data (6 x 5 =
30) to CPU.
and general purpose ports by instructions. Therefore, It
drives 126 segments at 1/3 duty in use of 3 commons and
42 segments or 164 segments at 1/4 duty in use of 4 and
41. Also it provides 4 general purpose output ports
maximum to drive LEDs or others directly.
voltage out of 8 steps voltage by the instruction to adjust
the display contrast of LCD panel.
GENERAL DESCRIPTION
FEATURES
42-segment Drivers
Programmable Duty Ratio
30-key Scan Function (6X5 matrix)
Programmable Bias Ratio 1/2, 1/3 bias
Output Port for LED (maximum 4 LED)
Serial Interface (SI, SO, SCL, CS)
Useful Instruction set
Incorporated LCD Driving Voltage Generator Circuits
Electrical Variable Resistance (8-step)
Logic Operating Voltage
LCD Driving Voltage
Package Outline
C-MOS Technology (Substrate :P)
The NJU6535 is a 1/3 or 1/4 duty LCD driver for
The NJU6535 chooses numbers of common, key scan,
Furthermore, the NJU6535 can select a LCD driving
Needless for anti-reverse current diodes in key scan
1/3 Duty : 126-segment (Maximum)
1/4 Duty : 164-segment (Maximum)
1/3 , 1/4 Duty LCD Driver
4.5 ~ 5.5V
~5.5V
QFP64-G1
QFP64-H1
!
PACKAGE OUTLINE
NJU6535FG1
NJU6535FH1
NJU6535
- 1 -

Related parts for NJU6535FH1

NJU6535FH1 Summary of contents

Page 1

... Output Port for LED (maximum 4 LED) # Serial Interface (SI, SO, SCL, CS) # Useful Instruction set # Incorporated LCD Driving Voltage Generator Circuits # Electrical Variable Resistance (8-step) # Logic Operating Voltage # LCD Driving Voltage # Package Outline # C-MOS Technology (Substrate :P) Ver.2004-04-16 ! 4.5 ~ 5.5V ~5.5V QFP64-G1 QFP64-H1 NJU6535 PACKAGE OUTLINE NJU6535FG1 NJU6535FH1 - 1 - ...

Page 2

NJU6535 ! PIN LOCATION OSC SO CE SCL SI ! BLOCK DIAGRAM VDD E.V. VSS ...

Page 3

TERMINAL DESCRIPTION 1 No. SYMBOL 1 SEG1/P0 2 SEG2/P1 3 SEG3/P2 4 SEG4/ SEG5 to SEG39 40 COM1 41 COM2 42 COM3 43 SEG40/COM4 44 SEG41/S0 45 SEG42/ ...

Page 4

NJU6535 ! FUNCTIONAL DESCRIPTION (1) Description for each blocks (1-1) Serial I/F The Serial I/F controls serial data from external data. (1-2) Instruction Reg. The Instruction Register stores instruction code from external. (1-3) Instruction Decoder. The instruction decoder decodes instruction ...

Page 5

INSTRUCTIONS The instruction code is consisted of 12-bits data and inputs with display data. (see “Table 1 Instruction Code Instruction Duty Select EVR Register Set Power Save mode set Segment output / Key scan output selection Segment ...

Page 6

NJU6535 (2) INSTRUCTIONS CODE (2-1) Duty select Duty select instruction is which sets LCD driving duty ratio 1/3 or 1/4 duty. No.43 terminal is change Common terminal or segment terminal shown below. Table 1 DY Duty ratio 0 1/3 Duty ...

Page 7

Segment output / General output port selection This instruction assigns function of output terminal either segment output or general purpose output port to 4 terminals numbered from shown in following table ...

Page 8

NJU6535 (3) Display data and output pin correspondence (3-1) 1/3Duty Output COM1 terminal SEG D1 1 SEG D4 2 SEG D7 3 SEG D10 4 SEG D13 5 SEG D16 6 SEG D19 7 SEG D22 8 SEG D25 9 ...

Page 9

Output COM1 COM2 terminal SEG SEG SEG D9 D10 3 SEG D13 D14 4 SEG D17 D18 5 SEG D21 D22 6 SEG D25 D26 7 SEG D29 D30 8 SEG D33 ...

Page 10

NJU6535 (4) Input Data Format and Timing Data format is shown below. When the CE terminal goes to “H” (rising edge) at SCL terminal “H”, I/F is data input. (4-1) 1/3Duty Data 1 (D1 to D42 and Instruction) CE SCL ...

Page 11

Data 1 (D1 to D44 and Instruction) CE SCL Data 2 (D45 to D84) CE SCL D45 D46 SI Display data SO Data 3 (D85 to D124) CE SCL D85 D86 SI Display data ...

Page 12

NJU6535 (5) Power save mode Power save mode set by “1” level as a control data in PS0 or 1, and released by “0” in PS0 and PS1. In power save mode, segment drivers and commons ...

Page 13

Timing of Key scan Key scan cycle is 288T[S]. The data of key scan is a result of comparison with a couple of Key scan for correct judge whether Key On or Off. When the result of comparison is ...

Page 14

NJU6535 (6-5) Normal mode Key scan operates with follows in normal mode. 1, Key scan signal output terminals S0 – S5 output “H” signals when key scan does not operate, and output key scan signals after start of key scan ...

Page 15

Power save mode Key scan operates with follows in Power save mode. 1, Key scan signal output terminals S0 – S5 output “H”, “L” signals by the control data S0 and S1 when key scan does not operate (refer ...

Page 16

NJU6535 (6-7) Key More Input Key scan signal output terminal output “H” level in state of Key More Input. Although Key state is detected without diodes to prevent unexpected key scan signal flow, non-pressed key data may ...

Page 17

Key data reading out operation by external CPU (a) Display data writing Display data and instruction change operate at the rising edge of signal into CE terminal. Written data or instructions do not operate during CE terminal “H”. When ...

Page 18

NJU6535 ! Timing chart of key data reading out operation Key input SO CE SCL Interrupt Decision - 18 - Key Key OFF Key ON t1: Key scan time t2: Key data read ...

Page 19

Power on reset circuit initializes Power on reset circuit initializes the NJU6535 at Power ON and OFF. It generates reset signal to initialize the system at low VDD less than power down detection voltage (2.5V typical). (7-1) Initial status ...

Page 20

NJU6535 (8) LCD panel drive (8-1) LCD driving voltage generation circuit LCD driving voltage generation circuit generates LCD driving bias voltages V0, V1 and V2. It adjusts the voltage by 8 steps electrical volume from VDD and allots the voltage ...

Page 21

ABSOLUTE MAXIMUMN RATINGS PARAMETER SYMBOL Supply Voltage VDDmax Input Voltage VI Output Voltage VO Power Dissipation Pdmax Storage Temperature Tstg Operating temperature Topr Note1) All voltage values are specified as Vss = 0V. Note2) If the LSI are used ...

Page 22

NJU6535 # ELECTRICAL CARACTERISTICS DC Characteristics PARAMETER SYMBOL Power supply ”H” level input voltage(1) VIH(1) ”H” level input voltage(2) VIH(2) ”L” level input voltage(1) VIL(1) Hysteresis voltage ”H” level input current ”L” level input current Pull-down resistance ”H” level output ...

Page 23

AC Characteristics PARAMETER SYMBOL “L” level tWCLL clock pulse width “H” level tWCLH clock pulse width Data setup time tDS Data hold time tDH CE wait time tCP CE setup time tCS CE hold time tCH CE ”L” level width ...

Page 24

NJU6535 # LCD DRIVING WAVEFORM (1) 1/3 Duty, 1/2 Bias Driving COM 1 COM 2 COM 3 “OFF” segment output correspond to COM , COM and COM 1 2 “ON” segment output correspond to COM 1 “ON” segment output correspond ...

Page 25

Duty, 1/3 Bias Driving COM 1 COM 2 COM 3 “OFF” segment output correspond to COM , COM and COM 1 2 “ON” segment output correspond to COM 1 “ON” segment output correspond to COM 2 “ON” segment ...

Page 26

NJU6535 (3) 1/4 Duty, 1/2 Bias Driving COM 1 COM 2 COM 3 COM 4 “OFF” segment output correspond to COM , COM , COM and COM “ON” segment output correspond to COM 1 “ON” segment output ...

Page 27

Duty, 1/3 Bias Driving COM 1 COM 2 COM 3 COM 4 “OFF” segment output correspond to COM , COM , COM and COM “ON” segment output correspond to COM 1 “ON” segment output correspond ...

Page 28

NJU6535 # APPLICATION CIRCUIT (1) 1/3 Duty, 1/2 Bias Driving (Not use E.V.R.) CPU * The rising time of Power source voltage at Power on and the falling time at Power off must ...

Page 29

The rising time of Power source voltage at Power on and the falling time at Power off must keep over than 1 mS because of Voltage detection type Reset circuit operation terminal requires external pull-up resistor connecting ...

Page 30

NJU6535 MEMO - 30 - [CAUTION] The specifications on this databook are only given for information , without any guarantee as regards either mistakes or omissions. The application circuits in this databook are described only to show representative usages of ...

Related keywords