MTCMR-C1-GP-N2 Multi-Tech Systems, MTCMR-C1-GP-N2 Datasheet - Page 117

no-image

MTCMR-C1-GP-N2

Manufacturer Part Number
MTCMR-C1-GP-N2
Description
MODEM CELLULAR DUAL CDMA
Manufacturer
Multi-Tech Systems
Series
MultiModem® iCellr
Datasheets

Specifications of MTCMR-C1-GP-N2

Function
Transceiver, CDMA, Modem
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz, 1575.42MHz
Applications
Sprint Networks (USA)
Interface
RS-232, USB
Sensitivity
-161dB
Data Rate - Maximum
153.6kbps
Voltage - Supply
9 V ~ 32 V, USB
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1096
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
AT+ADC=7<cr>
Request the secondary antenna ADC voltage.
Assume a +/- 5% variance in antenna ADC reading.
Powered short limit = 50 – (.05 *50) = 47
Powered open limit = 50 + (.05 * 50) =53.
AT+WANTLIM=1,2,47,53,190,210<cr>
Set secondary antenna diagnostic limits.
AT+WANT=1<cr>
Re-enable power to the antenna.
AT+WANTS<cr>
Check antenna diagnostic status
+ADC: 50
OK
OK
OK
+WANTS: 1,1
OK
Chapter 19 – Antenna Commands
117