MTCMR-C1-GP-N2 Multi-Tech Systems, MTCMR-C1-GP-N2 Datasheet - Page 123

no-image

MTCMR-C1-GP-N2

Manufacturer Part Number
MTCMR-C1-GP-N2
Description
MODEM CELLULAR DUAL CDMA
Manufacturer
Multi-Tech Systems
Series
MultiModem® iCellr
Datasheets

Specifications of MTCMR-C1-GP-N2

Function
Transceiver, CDMA, Modem
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz, 1575.42MHz
Applications
Sprint Networks (USA)
Interface
RS-232, USB
Sensitivity
-161dB
Data Rate - Maximum
153.6kbps
Voltage - Supply
9 V ~ 32 V, USB
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1096
The below table shows what impact AT&W, ATZ, and AT&F has on the various commands.
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
Command
Name
$BREW
$QCCHS
$QCCHV
$QCDMG
$QCDNSP
$QCDNSS
$QCHDRC
$QCHDRET
$QCHDRR
$QCHDRT
$QCMGD
$QCMGS
$QCMIP
$QCMIPEP
$QCMIPGETP
$QCMIPHA
$QCMIPMASPI
$QCMIPMASS
$QCMIPMASSX
$QCMIPMHSPI
$QCMIPMHSS
$QCMIPMHSSX
$QCMIPNAI
$QCMIPP
$QCMIPPHA
$QCMIPRT
$QCMIPSHA
$SPNAI
$QCOTC
$QCQNC
$QCQOSPRI
$QCSLOT
$QCSMP
$QCSO
$QCSYSMODE
$QCTER
$QCTRTL
AT&W – Save Configuration. This command writes the current configuration to NV.
ATZ – Reset to Default Configuration. This command restores the configuration last saved by AT&W.
AT&F – Restore Factory Settings. This command restores the factory default setting.
Chapter 21 – Effects of AT&W,
Saved Directly
to NV
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
ATZ, and AT&F
Saved to NV
with &W
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
Affected by Z
No
Yes (Set to 0)
No
No
No
No
Yes (Set to F)
Yes (Set to 0)
Yes (Set to F)
Yes (Set to 1)
No
No
Yes (Set to 0)
Yes (Set to 0)
Yes (Set to 0)
No
Yes (Set to 2,0)
No
Yes (Set to 0,0)
Yes (Set to 3,0)
No
Yes (Set to 0,0)
No
Yes (Set to 0)
No
Yes (Set to 0,0)
No
No
No
Yes (Set to 1)
Yes (Set to D)
Yes (Set to 1)
Yes (Set to
"4098",0,””,0,””)
Yes (Set to 2)
No
Yes (Set to “115200”)
Yes (Set to 1)
Chapter 21 – Effects of AT&W, ATZ, and AT&F
Affected by &F
No
Yes (Set to 0)
No
No
No
No
Yes (Set to F)
Yes (Set to 0)
Yes (Set to F)
Yes (Set to 1)
No
No
Yes (Set to 0)
Yes (Set to 0)
Yes (Set to 0)
No
Yes (Set to 2,0)
No
Yes (Set to 0,0)
Yes (Set to 3,0)
No
Yes (Set to 0,0)
No
Yes (Set to 0)
No
Yes (Set to 0,0)
No
No
No
Yes (Set to 1)
Yes (Set to D)
Yes (Set to 1)
Yes (Set to
"4098",0,””,0,””)
Yes (Set to 2)
No
Yes (Set to “115200”)
Yes (Set to 1)
No
No
No
Listed
by &V
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
123

Related parts for MTCMR-C1-GP-N2