8808A/SU 120V Fluke Electronics, 8808A/SU 120V Datasheet - Page 39

USB CABLE KIT SW DMM 5.5 RES

8808A/SU 120V

Manufacturer Part Number
8808A/SU 120V
Description
USB CABLE KIT SW DMM 5.5 RES
Manufacturer
Fluke Electronics
Type
Digital (DMM)r
Datasheet

Specifications of 8808A/SU 120V

Includes
Test Leads
Style
Bench
Display Digits
5.5
Display Type
VFD, Dual
Display Count
200000
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, dB, Diode Test
Features
Hold, Min/Max, RS-232 Port
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Other names
614-1069
No.
I
J
K
L
M
N
O
P
Q
J
I
T
W
N
F
D
A
E
B
O
G
R
10 A
mA
Name
Table 3-1. Front-Panel Features (cont.)
Toggles between manual and autorange modes
Uand V increase and decrease the range for manual
ranging
Input terminal for 10 A ac and dc current measurement
Input terminal for 200 mA ac and dc current measurement
Primary operation: Sets the Meter’s measurement rate to slow,
medium or fast
Second level operation: Selects source for triggering
measurement
Primary operation: Selects Touch Hold function
Second level operation: Sets Touch Hold minimum response
level
Primary operation: Selects relative readings function to display
difference between relative base and input
Second level operation: Sets relative base
Primary operation: Selects dB measurement mode
Second level operation: sets dB reference impedance
Stores the minimum and maximum inputs measured
Selects measurement function:
Frequency
DC voltage
AC voltage
DC current
AC current
Resistance (ohms)
Continuity / diode test (toggles)
Operating the Meter from the Front Panel
Description
Introduction
3
3-5