7-435470-1 Tyco Electronics, 7-435470-1 Datasheet - Page 3

no-image

7-435470-1

Manufacturer Part Number
7-435470-1
Description
DIP SW ASSY-BLK EXT ACT-2POS
Manufacturer
Tyco Electronics
Datasheets

Specifications of 7-435470-1

Rohs Information
7-435470-1
Circuit
SPDT
Number Of Positions
2
Contact Rating @ Voltage
0.1A @ 5VDC
Actuator Type
Standard
Actuator Level
Raised
Mounting Type
Through Hole
Orientation
Top Actuated
Washable
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Solderability.
Vibration.
Physical shock.
Resistance to soldering heat.
Term inal strength, pull test.
Term inal strength, bend test.
Durability.
Actuation force.
Therm al shock.
Hum idity-tem perature cycling.
Tem perature life.
Rev V
Test Description
No physical dam age.
Contact post shall have a m inim um
of 95% solder coverage.
No discontinuities of 10
m icroseconds or longer duration.
No physical dam age.
No discontinuities of 10
m icroseconds or longer duration.
No Physical dam age.
No physical dam age.
No physical dam age.
No physical dam age.
24 ounces m axim um per switch
actuator initially and after durability.
Switch shall be able to withstand a
total actuation force of 3 pounds
without resulting in im proper
operation or switch dam age.
No physical dam age.
No physical dam age.
No physical dam age.
Figure 1 (continued)
ENVIRONMENTAL
MECHANICAL
Requirem ent
TE Spec 109-63-3.
TE Spec 109-64, Condition A.
TE Spec 109-64, Condition B.
Subject m ounted switch to 7000
TE Spec 109-22.
TE Spec 109-23-3, Condition B.
TE Spec 109-43, Test Level 3,
TE Spec 109-11-3.
Subject switch to solderability.
TE Spec 109-21-4.
Subject switches to 20 G’s, 10-2000
Hz with 100 m a current applied.
TE Spec 109-26-1.
Subject m ounted switch to 50 G's
half-sine shock pulses of 11
m illiseconds duration. 3 shocks in
each direction applied along 3
m utually perpendicular planes, 18
total shocks.
Subject switch in OFF position to
soldering heat.
Subject 10 random switch term inals
to an axial pull of 2 pounds.
Subject 10 random switch term inals
to two 45 bend cycles.
cycles of actuation with a resistive
load of 24 vdc and 25 m a m axim um
current applied.
Apply force to switch actuators with
the switch m ounted as shown in
Figure 4.
Subject switches in the ½ ON and
½ OFF condition to 5 non- operating
cycles between -55° and 105 C.
Subject switches to hum idity
between 90 and 100% RH while
tem perature cycles between 25 and
65°C twice in 24 hours. 10 cycles
are to be com pleted. Measure
insulation resistance during
recovery period.
Duration A.
Subject switches in ON condition to
tem perature life.
Procedure
108-7519
3 of 7

Related parts for 7-435470-1