H7BX-A AC100-240 Omron, H7BX-A AC100-240 Datasheet - Page 14

1-stg 72x72 Multifunc Counter

H7BX-A AC100-240

Manufacturer Part Number
H7BX-A AC100-240
Description
1-stg 72x72 Multifunc Counter
Manufacturer
Omron
Datasheet

Specifications of H7BX-A AC100-240

Display Type
LCD Backlight
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
■ Input/Output Mode Settings
Operation for 1-stage models is the same as that for OUT2.
When using a 2-stage model as a 1-stage counter, total and preset counter,
or dual counter, OUT1 and OUT2 turn ON and OFF simultaneously.
14
Output
mode
setting
K-1
N
C
R
F
Multifunction Counter
999999
999999
999999
999999
999999
Set
value 2
Set
value 1
Set
value 2
Set
value 1
Set
value 2
Set
value 1
Set
value 2
Set
value 1
Set
value 2
Set
value 1
Reset/
reset 1
OUT1
OUT2
Reset/
reset 1
OUT1
OUT2
Reset/
reset 1
OUT1
OUT2
Reset/
reset 1
OUT1
OUT2
Reset/
reset 1
OUT1
OUT2
0
0
0
0
0
UP
H7BX
Input mode
DOWN
UP/DOWN A, B, C
Self-holding
output
One-shot output from OUT1
Self-holding
output
One-shot output
from OUT2
The outputs and present
value display are held
until reset/reset 1 input
turns ON.
The present value
display continues to
increase/decrease. The
outputs are held until
reset/reset 1 input turns
ON.
As soon as the count
reaches SV, the present
value display returns to
the reset start status.
The present value
display does not show
the present value upon
count-up.
The outputs repeat one-
shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
display returns to the
reset start status after
the one-shot output
time.
The outputs repeat one-
shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
display continues to
increase/decrease.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time.
The OUT1 one-shot
output time is
independent of OUT2.
Operation after count
(The one-shot output time
can be set in the range
0.01 to 99.99s.)
completion

Related parts for H7BX-A AC100-240