● Total and Preset Counter Operation
The H7BX has a total counter separate from the 1-stage preset counter for counting the total accumulated value.
● Batch Counter Operation
The H7BX has a batch counter separate from the 1-stage preset counter for counting the number of times the count has been completed.
Note 1. The batch count value is held at 0 while the batch counter reset input is on.
● Dual Counter Operation
Using the dual counter allows the count from 2 inputs to be added or subtracted and the result displayed. It is possible to specify a set
value for which output turns ON when the set value matches the added or subtracted result.
Note 1. Counting is not possible for CP1 while the reset 1 input is ON. CP2 is not affected. The dual count value will be calculated based on a CP1 present value of 0.
(1) Dual Count Calculating Mode = ADD
Dual count value = CP1 PV + CP2 PV
Dual count set value
CP1 present value
CP2 present value
2. If the batch count set value is 0, batch count will be performed but there will be no batch output.
3. The batch count value returns to 0 when it reaches 999,999.
4. Once batch input has been turned ON, it will return to the ON state after power interruptions.
5. If the batch count set value is changed from a value that is greater than the batch count value to one that is less, batch output will turn ON.
6. After batch output turns ON, the ON state will be held even if the batch count set value is changed to a value greater than the batch count value.
2. Counting is not possible for CP2 while the reset 2 input is ON. CP1 is not affected. The dual count value will be calculated based on a CP2 present value of 0.
3. The counting range for the dual count value is 99,999 to 999,999.
Dual count value
The counting ranges for the CP1 present value and CP2 present value are 0 to 999,999.
If a present value exceeds 999,999, FFFFFF will be displayed to indicate an overflow, and all counting will stop.
Total reset/reset 2
(CP1 reset)
(CP2 reset)
Total count value
Batch count set value
OUT1 (batch output)
Note: The above is for when the output mode is N.
OUT1, 2
Reset 1
Reset 2
Present value
Batch count value
Reset/reset 1
Reset 2 (batch
(Main display)
counter reset)
Present value
(Sub-display)
0
0
0
999999
Set value
Reset 1
OUT2
0
0
0
0
Note: The above is for when the output mode is C.
1
2
(2) Dual Count Calculating Mode = SUB
Dual count value = CP1 PV - CP2 PV
Dual count set value
CP1 present value
CP2 present value
Dual count value
Note: The above is for when the output mode is K-2.
(CP1 reset)
(CP2 reset)
SUB mode can be used only when K-2, D, L, or H
is selected as the output mode with 6-digit models.
OUT1, 2
Reset 1
Reset 2
0
0
0
Multifunction Counter
The total counter continues to count the total
accumulated value when the present value is reset
using reset/reset 1 input (Reset Key).
The total count value is reset when the total reset/
reset 2 input is turned ON.
If the Reset Key is pressed while the total count
value is displayed, the total count value is reset.
The present value is also reset at this time.
The counting range of the total counter is 99,999
to 999,999. The total count value returns to 0 when
it reaches the full scale limit.
The batch counter continues after count
completion.
Batch output is held until batch counter reset input
turns ON.
When the batch counter reset input is turned ON,
the batch count value is reset, and batch output
turns OFF.
If the Reset Key is pressed while the batch count
value is displayed, the batch count value is reset
and batch output turns OFF. The present value is
also reset at this time.
The operation after count completion for the dual
counter value is determined by the output mode.
The CP1 present value is reset when reset 1 input
is turned ON and the CP2 present value is reset
when reset 2 input is turned ON.
If the Reset Key is pressed while the dual count
value, CP1 present value, or CP2 present value is
displayed, all of the present values are reset and
the outputs turn OFF. At this time, counting is not
possible for CP1 or CP2 inputs.
H7BX
17