Forcing Bit Status
Timer Accuracy
306
Timer Area
TIMER: TIM or TIMX
HIGH-SPEED TIMER:
TIMH(015) or TIMHX(551)
ONE-MS TIMER:
TMHH(540) or TMHHX(552)
ACCUMULATIVE TIMER:
TTIM(087) or TTIMX(555)
TIMER WAIT: TIMW(813) or
TIMWX(816)
HIGH-SPEED TIMER WAIT:
TMHW(815) or TMHWX(817)
Instruction name
Note
PV
Flag
Mode change
The following table shows when timer PVs and Completion Flags will be reset.
1. If the IOM Hold BIt (A50012) is ON, the PV and Completion Flag will be
2. If the IOM Hold BIt (A50012) is ON and the PLC Setup’s “IOM Hold Bit Sta-
3. Since the TIML(542), TIMLX(553), MTIM(543), and MTIMX(554) instruc-
4. The present value of TIM, TIMX, TIMH(015), TIMHX(551), TMHH(540),
Timer Completion Flags can be force-set and force-reset.
Timer PVs cannot be force-set or force-reset, although the PVs can be
refreshed indirectly by force-setting/resetting the Completion Flag.
The accuracy of timers is different for Duplex CPU Systems than for Single
CPU Systems or CS1-H CPU Units.
Accuracy in Normal Operation
The following table shows the timer accuracy in normal operation.
TIMER: TIM or TIMX
HIGH-SPEED TIMER:
TIMH(015) or TIMHX(551)
ONE-MS TIMER: TMHH(540) or
TMHHX(552)
ACCUMULATIVE TIMER:
TTIM(087) or TTIMX(555)
MULTI-OUTPUT TIMER: MTIM(543) or
MTIMX(554)
TIMER WAIT: TIMW(813) or TIMWX(816)
HIGH-SPEED TIMER WAIT:
TMHW(815) or TMHWX(817)
Effect on PV and Completion Flag
0
OFF
retained when a fatal error occurs or the operating mode is changed from
PROGRAM mode to RUN or MONITOR mode or vice-versa. The PV and
Completion Flag will be cleared when power is cycled.
tus at Startup” setting is set to protect the IOM Hold Bit, the PV and Com-
pletion Flag will be retained when the PLC’s power is cycled.
tions do not use timer numbers, they are reset under different conditions.
Refer to the descriptions of these instructions for details.
TMHHX(552), TIMW(813), TIMWX(816), TMHW(815), and TMHWX(817)
timers are held when the timer is jumped between JMP and JME instruc-
tions or when in a task that is on standby.
1
PLC start-up
PV
Flag
Timer
0
OFF
2
PV
Flag
CNR(545) or
CNRX(547)
9999
OFF
( 10 ms to 0 ms) + (0 ms to
cycle time)
Tasks on standby
PV Maintained
(JMP-JME) or
Jumps
Jumps and Interlocks
Accuracy
Operation in
4
PV
(Reset to SV.)
Flag
PV Maintained
---
---
Section 8-13
Interlocks
(IL-ILC)
SV
OFF
Related parts for CS1D-DPL02D
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
CS1D Dual IO Control Unit
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CS1D Dual IO Interface Unit
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CS1D Dual CPU Exp
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
CS1D Dual Exp Rack
Manufacturer:
Omron
Datasheet:
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: