CS1W-CLK53 Omron, CS1W-CLK53 Datasheet - Page 3

no-image

CS1W-CLK53

Manufacturer Part Number
CS1W-CLK53
Description
Controller Link Mod GI Optical
Manufacturer
Omron
Datasheet

Specifications of CS1W-CLK53

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Ordering Information
● Controller Link Units, New Models
● Controller Link Units, Old Models
New models are fully compatible with old models and provide enhanced functionality, such as an increase in the number of send words from 1,000 to 4,000
words. Select a new model when ordering.
Note:
1. Use the following special cable for shielded, twisted-pair cable.
2. When using a wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable with
3. When using a wire-to-optical (GI) cable, use a GI optical cable that matches the specifications.
4. Pre-Ver. 1.2 Controller Link Units support 4 Units maximum for non-duplex and 7 Units maximum for duplex (6 Units comprising 3 sets of Duplex Units
classifica
CS1
CPU
Bus Unit
classification
CS1
CPU
Bus Unit
・ ESVC0.5×2C-13262 (Bando Electric Wire : Japanese Company)
・ ESNC0.5×2C-99-087B (Nihon Electric Wire & Cable Corporation : Japanese Company)
・ Li2Y-FCY2×0.56qmm (Kromberg & Schubert, Komtec Department : German Company)
・ 1×2×AWG–20PE+Tr.CUSN+PVC (Draka Cables Industrial : Spanish Company)
・ #9207 (Belden : US Company)
Unit
tion
connector.
+ 1 Non-duplex Unit).
Unit
Controller
Link
Unit
Controller
Link
Unit
Controller
Link
Unit
Product
name
Controller
Link
Unit
Product
name
Wired shielded
(See note 1.)
Optical ring H-PCF
(See note 2.)
Optical ring GI cable
(See note 3.)
twisted-pair cable
cable
Wired shielded
(See note 1.)
Optical ring H-PCF
(See note 2.)
Optical ring GI cable
(See note 3.)
twisted-pair cable
cable
Communications
Communications
cable
cable
Data links and
message service
Data links and
Communications
Communications
message service
type
type
Specifications
Specifications
No
Yes. Unit
duplexing and
cable loop
back are
supported.
No
Yes. Unit
duplexing
and cable
loop back are
supported.
support
Duplex
support
Duplex
8
Non-duplex: 8,
8
Non-duplex: 8,
(See note 4.)
Duplex: 11 (6 Units
comprising 3 sets of
Duplex Units + 5
Non-duplex Units)
Duplex: 11 (6 Units
comprising 3 sets of
Duplex Units + 5
Non-duplex Units)
mountable per
mountable per
Max. Units
Max. Units
CPU Unit
CPU Unit
1
1
1
1
1
1
No. of unit
No. of unit
allocated
allocated
numbers
numbers
0.33
0.52
0.65
0.33
0.52
0.65
consumption
consumption
DC
DC
5V
5V
Current
Current
(A)
(A)
26 V
26 V
DC
DC
CS1W-CLK23
CS1W-CLK13
CS1W-CLK53
CS1W-CLK21-V1
CS1W-CLK12-V1
CS1W-CLK52-V1
Note: New models
are listed above.
Model
Model
UC1,
N, L, CE
UC1,
N, L, CE
Standards
Standards
3

Related parts for CS1W-CLK53