CS1W-CLK53 Omron, CS1W-CLK53 Datasheet - Page 4

no-image

CS1W-CLK53

Manufacturer Part Number
CS1W-CLK53
Description
Controller Link Mod GI Optical
Manufacturer
Omron
Datasheet

Specifications of CS1W-CLK53

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
● Controller Link Support Boards, New Models
● Controller Link Support Boards, Old Models
New models are fully compatible with old models and provide enhanced functionality, such as an increase in the number of send words from 1,000 to 4,000
words. Select a new model when ordering.
● Repeater Units
Using Repeater Units enables T-branches and long-distance wiring for Wired Controller Link networks, 62-node configurations, and converting part of the
network to optical cable.
Note:
1. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable with connector.
2. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).
● Relay Terminal Block
Controller Link Units can be replaced without stopping the communications of the entire network if a Relay Terminal Block is installed in advance on the
Unit in a Wired Controller Link network. Relay Terminal Blocks cannot be used on Controller Link Support Boards.
● Duplex Optical Fiber Cable (H-PCF Cable)
This cable is used to connect Units in active mode (ACT) and standby mode (STB) in a CS1D Duplex System.
Controller Link
Support Board
for PCI Bus
Controller Link
Support Board
for PCI Bus
Controller Link
Repeater Unit
Relay Terminal Blocks for
Wired Controller Link Units
Duplex Optical Fiber Cable
Product name
Product name
Name
Name
Name
Wired shielded
H-PCF optical model
GI optical model
Wired shielded
H-PCF optical model
GI optical model
twisted-pair cable
twisted-pair cable
Communications
Communications
cable
cable
CS1W-CLK13 or
CS1W-CLK12-V1 in a CS1D system
Specifications
Specifications
Used for Wired Controller Link Units (set of 5)
Wire-to-Wire Model
Wire-to-Optical (H-PCF) Model (See note 1.)
Wire-to-Optical (GI) Model (See note 2.)
Data links and message
Data links and message
service
service
Application
Communications type
Communications type
Specifications
Specifications
Communications Middleware FinsGateway
Communications Middleware FinsGateway
Version 2003 and Version 3 are supplied.
Version 2003 and Version 3 are supplied.
H-PCF cable for connecting Duplex Controller Link Units
Cable length: 50 cm
Accessories
Accessories
Specifications
CJ1W-TB101
CS1W-RPT01
CS1W-RPT02
CS1W-RPT03
3G8F7-CLK23-E
3G8F7-CLK13-E
3G8F7-CLK53-E
3G8F7-CLK21-EV1
3G8F7-CLK12-EV1
3G8F7-CLK52-EV1
Note: New models are listed above.
Model
Model
Model
Model
CS1D-CN051
Model
UC1, CE
CE
CE
Standards
Standards
Standards
Standards
Standards
4