DSEP30-12CR IXYS, DSEP30-12CR Datasheet - Page 4

DIODE FRED 1200V 30A ISOPLUS247

DSEP30-12CR

Manufacturer Part Number
DSEP30-12CR
Description
DIODE FRED 1200V 30A ISOPLUS247
Manufacturer
IXYS
Series
HiPerDynFRED™r
Datasheet

Specifications of DSEP30-12CR

Voltage - Forward (vf) (max) @ If
5V @ 30A
Voltage - Dc Reverse (vr) (max)
1200V (1.2kV)
Current - Average Rectified (io)
30A
Current - Reverse Leakage @ Vr
250µA @ 1200V
Diode Type
Standard
Speed
Fast Recovery =< 500ns, > 200mA (Io)
Reverse Recovery Time (trr)
20ns
Mounting Type
Through Hole, Radial
Package / Case
ISOPLUS247™
Vrrm, (v)
1200
Ifavm, D = 0.5, Total, (a)
30
Ifavm, D = 0.5, Per Diode, (a)
30
@ Tc, (°c)
120
Vf, Max, If=ifavm, (v)
3.18
@ Tvjm, (°c)
150
Trr, Typ, Tvj =25°c, (ns)
15
Irm , Typ, Tvj =100°c, (a)
12.5
@ -di/dt, (a/µs)
600
Tvjm, (°c)_
175
Rthjc, Max, (k/w)
0.60
Package Style
ISOPLUS247™
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Capacitance @ Vr, F
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DSEP30-12CR
Manufacturer:
IXYS
Quantity:
210
IXYS reserves the right to change limits, conditions and dimensions.
©
[A]
K
[K/W]
Z
I
2011 IXYS all rights reserved
F
f
thJC
2.5
2.0
1.5
1.0
0.5
0.0
0.8
0.6
0.4
0.2
0.0
80
60
40
20
0.0001
0
0
0
Fig. 4 Dynamic parameters
Fig. 1 Forward current I
Fig. 7 Transient thermal resistance junction to case
T
T
T
VJ
VJ
VJ
I
Q
= 150°C
= 100°C
= 25°C
RM
rr
40
Q
2
r
, I
RM
V
T
0.001
VJ
F
versus T
80
4
[V]
[°C]
120
6
VJ
F
vs. V
0.01
160
8
F
[nC]
t [s]
[ns]
Q
t
rr
r
160
140
120
100
800
700
600
500
400
300
200
100
80
60
40
20
1
0
0
0.1
Fig. 2 Reverse recovery charge
Fig. 5 Recovery time
0
T
V
VJ
R
200
= 600 V
= 100°C
Q
t
rr
I
I
I
r
Data according to IEC 60747and per diode unless otherwise specified
F
F
F
-di
versus -di
-di
versus -di
= 60 A
= 30 A
= 15 A
400
F
F
/dt [A/µs]
/dt [A/µs]
1
600
T
V
F
F
VJ
R
I
I
I
/dt
/dt
F
F
F
= 600 V
= 60 A
= 30 A
= 15 A
= 100°C
800
1000
1
0
10
0
0
V
[V]
I
[A]
RM
FR
25
20
15
10
40
30
20
10
5
0
0
Constants for Z
1 0.08
2 0.122
3 0.116
4 0.23
5 0.052
0
0
i
Fig. 3 Peak reverse current
Fig. 6 Peak forward voltage
V
FR
R
T
V
thi
200
200
VJ
R
(K/W)
= 600 V
= 100°C
I
DSEP30-12CR
V
RM
I
I
I
F
F
F
FR
-di
= 60 A
= 30 A
= 15 A
400
400
T
I
versus -di
-di
F
and tfr versus di
F
VJ
= 100 A
/dt [A/µs]
F
= 100°C
thJC
/dt [A/µs]
0.0013
0.0097
0.037
0.07
0.45
600
600
t
calculation:
i
(s)
F
/dt
800
800 1000
t
F
1000
fr
/dt
20110201a
0.6
0.5
0.4
0.3
0.2
t
[µs]
rr

Related parts for DSEP30-12CR