ES-FA-6G BANNER ENGINEERING, ES-FA-6G Datasheet

no-image

ES-FA-6G

Manufacturer Part Number
ES-FA-6G
Description
ES-FA-6G SINGLE OUTPUT E-STOP
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of ES-FA-6G

Relay Mounting
DIN Rail
Peak Reflow Compatible (260 C)
No
Coil Voltage Vdc Nom
24V
External Width
22.5mm
Contact Voltage Ac Nom
250V
External Depth
118.2mm
Coil Voltage Vac Nom
24V
Contact Current Max
6A
Contact Voltage Dc Nom
250V
External Height
82mm
Printed in USA
!
WARNING . . .
defined by OSHA regulations. It is necessary to install point-of-operation guarding devices, such as safety
light curtains and/or hard guards, to protect personnel from hazardous machinery. Failure to install point-of-
operation guards on hazardous machinery can result in a dangerous condition which could lead to serious
injury or death.
This Emergency Stop Safety Module is not a point-of-operation guarding device, as
®
• Monitors one single-channel normally closed Emergency Stop switch circuit for
• Three output switching channels for connection to control-reliable power
• Auto reset or manual reset
• One auxiliary non-safety N/C output contact for status monitoring by process
• Design complies with standards UL991, EN418, and EN954-1
• For use in functional stop category 0 applications per NFPA 79
• 6 amp safety output contacts
24V ac/dc operation
ES-FA-6G 1-Channel Emergency Stop Safety Module
a contact failure or wiring fault
interrupt circuits
controller
(Safety Category 2)
and EN418
E-Stop Safety Module Features
P/N 55581B9A

Related parts for ES-FA-6G

ES-FA-6G Summary of contents

Page 1

... Printed in USA ® ES-FA-6G 1-Channel Emergency Stop Safety Module 24V ac/dc operation E-Stop Safety Module Features • Monitors one single-channel normally closed Emergency Stop switch circuit for a contact failure or wiring fault • ...

Page 2

... Also, request a type “C” standard for your specific machinery. EN418 “Safety of Machinery – Emergency Stop Equipment Functional Aspects, Principles for Design” Available from: 2 page – Model ES-FA-6G read this page before proceeding! Safety Director AMT – The Association for Manufacturing Technology 7901 Westpark Drive McLean, VA 22101-4269 Tel ...

Page 3

... In a functional Category 0 emergency stop circuit, opening of the E-stop switch contact(s) immediately removes power from the machine control elements, which react to arrest machine hazards. As indicated in Figures 3, 4, and 5, the model ES-FA-6G E-Stop Safety Module is designed for use with a 1-channel E-stop switch. A 1-channel E-stop switch has one contact. The customer-supplied E-stop switch must be a “ ...

Page 4

... NEMA 3 (IEC IP54) rating, or better. Dimensions of the Safety Module are shown in the diagram on page 11. The Safety Module mounts directly to standard 35 mm DIN rail. 4 page – Model ES-FA-6G CAUTION Shock Hazard Always disconnect power from the E-stop Safety Module and all power from the machine being controlled before making any wire connections ...

Page 5

... ANSI B11.1 – 1988, Appendix B4) E-Stop Safety Module +V Emergency Stop Switch Machine Control Circuits 33 41 Figure 2. Hookup of ES-FA-6G E-Stop Safety Module – Model ES-FA-6G dc common 24V ac/dc A2 ES-FA-6G MSC1 MSC3 Y1 MSC Monitor Contacts Y2 Reset MSC2 Switch (jumper for auto reset - ...

Page 6

... Module which interfaces to a multitude of machine control configurations. The following guidelines are general in nature. The ES-FA-6G has no delay function. Its output relay contacts open within 35 milliseconds after the E-stop switch contact opens. This classifies this E-stop Safety Module as a functional “Category 0” E-stop control as defined by NFPA 79 (National Fire Protection Association Standard for Industrial Machinery) and EN418 (European Standard: “ ...

Page 7

... Reset procedure. Automatic Reset Mode Model ES-FA-6G may be configured for automatic reset by replacing the Reset switch with a jumper wire in the Y1-Y2 feedback/reset input circuit (see Figure 2). The E-stop Safety Module will reset (and the outputs energize) as soon as the E-stop switch returns to its closed-contact position ...

Page 8

... Close and then open the Reset switch (if using manual reset mode). Verify that the machine restarts. NOTE: If two or more E-stop switches are series-connected to one E-stop Safety Module, this test must be individually run for EACH switch. 8 page – Model ES-FA-6G CAUTION . . . Disconnect Power Prior to Checkout Before performing the initial checkout procedure, make certain all power is disconnected from the machine to be controlled ...

Page 9

... E-Stop Safety Module NOTE: Do not attempt any repairs to the ES-FA-6G Emergency Stop Safety Module. It contains no field-replaceable components. Return the Safety Module to the factory for warranty repair or replacement ever becomes necessary to return an E-stop Safety Module to the factory, please do the following: 1) Contact the Banner Factory Application Engineering Group at the address or at the numbers listed at the bottom of the back page ...

Page 10

... Maximum Relative Humidity: 90% @ +50°C (non-condensing) Dimensions See Figure 4. 10 page – Model ES-FA-6G E-Stop Safety Module Product Specifications three redundant (total of six) safety relay (forced-guided) contacts – AgSnO one auxiliary non-safety monitor output (open when both K1 and K2 are energized; closed when either are de-energized) ...

Page 11

... Figure 4. E-Stop Safety Module enclosure dimensions E-Stop Safety Module WARRANTY VOID IF OPENED 80 mm (3.15" (3.23") DIN Mounting Tab (Supplied) – Model ES-FA- ES-FA- Power 22.5 mm (.88") 35.0 mm (1.38") DIN Mounting Slot 11 page ...

Page 12

... This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN 55441 • Phone: 612.544.3164 • Fax: 612.544.3213 • Email: sensors@baneng.com – Model ES-FA-6G ® ...

Related keywords