ES-FA-9AA BANNER ENGINEERING, ES-FA-9AA Datasheet
ES-FA-9AA
Specifications of ES-FA-9AA
Related parts for ES-FA-9AA
ES-FA-9AA Summary of contents
Page 1
... Model ES-FA-9AA (24V ac/dc, 3 N/O) • Monitors one dual-channel normally closed emergency stop switch circuit for a contact failure or wiring fault • The ES-FA-9AA has three output switching channels for connection to control- reliable power interrupt circuits • Auto reset or monitored manual reset • ...
Page 2
... ISO 13849-1 (EN954-1) IEC/EN60204-1 ISO 13850 (EN418) “Safety of Machinery – Emergency Stop Equipment Functional Aspects, Principles for Design” P/N 60606 rev. B ES-FA-9AA read this page before proceeding! Safety Director AMT – The Association for Manufacturing Technology 7901 Westpark Drive McLean, VA 22102 Tel ...
Page 3
... E-stop switch is the first step towards control reliability in an emergency stop circuit. The output of the E-Stop Safety Module ES-FA-9AA consists of three redundant output switching channels, each of which is the series connection of two forced-guided relay contacts that are internally monitored (K1 and K2 in Figure 2). If the Module detects a failure, such as a welded output relay contact, all outputs are disabled and cannot be reset ...
Page 4
... If not, the unit will go into a lockout condition that results in the outputs opening and requiring a reset after the fault has been corrected. 4 P/N 60606 rev. B ES-FA-9AA ! WARNING . . . 1-Channel Input If a 1-channel E-stop ...
Page 5
... Jumper S4 MSC See WARNING Below Machine Master Stop Control Elements MSC1 4 MSC MSC 4 *Arc suppressors (see WARNING) ES-FA-9AA Manual Reset +V dc common 4V ac/ S ES-FA-9AA S11 S4 (No Connection) S1 E-Stop Switch S S1 Machine Master Stop Control Elements 6A max max Machine 4 Control Circuits 6A max ...
Page 6
... S4 MSC See WARNING on page Machine Master Stop Control Elements MSC1 Machine 4 MSC MSC 4 *Arc suppressors (see WARNING) Manual Reset dc common 4V ac/dc E-Stop Switch A A1 S ES-FA-9AA S11 (No Connection) S4 S1 S S1 Machine Master Stop Control Elements 6A max MSC1 6A max MSC Control Circuits 6A max ...
Page 7
... Module which interfaces to a multitude of machine control configurations. The following guidelines are general in nature. The ES-FA-9AA Module has no delay function. Its output relay contacts open within 25 milliseconds after an E-stop switch contact opens. This classifies these E-Stop Safety Modules as functional “Category 0” E-stop controls, as defined by NFPA 79 (National Fire Protection Association Standard for Industrial Machinery) and IEC/EN60204-1 (European Standard: “ ...
Page 8
... Reset procedure. Automatic Reset Mode The ES-FA-9AA module may be used also with automatic reset MSC-monitor contacts are monitored, a jumper must be installed between terminals S33 and S34 (see Figures 2 and 3). The E-Stop Safety Module will reset (and the outputs energize) as soon as the E- stop switch returns to its closed-contact position ...
Page 9
... Return the E-stop switch to its closed-contact position. Verify that the machine does not restart. 3. Close and then open the Reset switch (if using manual reset mode). Verify that the machine restarts. NOTE: If two or more E-stop switches are series-connected to one E-Stop Safety Module, this test must be run individually for EACH switch. ES-FA-9AA 9 P/N 60606 rev. B ...
Page 10
... K1 CH S S4 S1 Figure 6. Model ES-FA-9AA E-Stop Safety Module enclosure dimensions 10 P/N 60606 rev. B ES-FA-9AA Repairs 118.0 mm (4.6") ! CAUTION ... Abuse of Module After Failure If an internal fault has occurred and the Module will not reset, do not tap, strike, or otherwise attempt to correct the fault by a physical impact to the housing ...
Page 11
... Tel: 763.544.3164 E-Stop Safety Module – Specifications applications, multiple contacts can also be switched in series (e.g., “dry switching”). Max. voltage: 60V Max. current: 300 mA Max. power VA) Max. voltage: 250V ac/dc Max. current Max. power: 200 W (1,500 VA) ES-FA-9AA 11 P/N 60606 rev. B ...
Page 12
... This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied. P/N 60606 rev. B Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com ES-FA-9AA ® ...