Potentiometers 10K Ohm 20% 1/20W 6mm

585SX4Q25F103SP

Manufacturer Part Number
585SX4Q25F103SP
Description
Potentiometers 10K Ohm 20% 1/20W 6mm
Manufacturer
Honeywell
Type
Potentiometerr
Series
585r
Datasheets

Specifications of 585SX4Q25F103SP

Resistance
10kohm
Power Rating
1/20W
Tolerance (+ Or -)
20%
Number Of Turns
1Turn
Technology
Carbon Film
Mounting Style
Panel
Termination Style
Pin
Operating Temp Range
-55C to 120C
Failure Rate
Not Required
Shaft Diameter (mm)
6mm
Product Diameter (mm)
Not Requiredmm
Product Length (mm)
19.5mm
Product Height (mm)
11.35mm
Product Depth (mm)
9.5mm
Tolerance
20 %
Taper
Linear
Element Type
Carbon
Shaft Type
Flatted / D
Shaft Length
19.05 mm
Shaft Diameter
6 mm
Product
Commercial Potentiometer
Voltage Rating
50 Volts
Angle, Mechanical
300 °
Application
For manual controls, telecommunications and audio equipment
Diameter, Shaft
0.236 "
Dimensions
9.5mmL×9.5mmW×5mmH
Linearity
±5 %
Material, Element
Carbon
Mounting Type
PCB
Power, Rating
0.05 W
Rotational Life
10000 Cycles
Shaft Style
Flatted Shaft
Termination
PC Pins
Voltage, Operating
50 VAC
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
585SX4Q25F103SP
Manufacturer:
HONEYWELL
Quantity:
20 000
PRESSURE SENSORS
TLD Series
140
OPTIONS
Flow-through/Output Signal 4 mA to 20 mA
MEASUREMENT TYPE
Compound
Compound
Compound
Flow-through/Output Signal 0 Vdc to 5.0 Vdc
MEASUREMENT TYPE
Compound
Single Port/Output Signal 4 mA to 20 mA
MEASUREMENT TYPE
Compound
With space at a premium in semiconductor gas distribution systems, the Series TLD pressure transducer with local
display offers an integrated solution that reduces the overall height of the transducer/display assembly to as little as 3.5
in [88,9 mm]. To accomplish this, the transducer’s signal amplifier is mounted within the display, with the added benefit
of zero and span adjustments conveniently located on the LED display face.
Supply voltage:
Signal conditioning:
Operating temperature range:
Compensated temperature range:
Termination type:
BF - Transducer at bottom, front display orientation
BS - Transducer at bottom, side display orientation
z
38,1
1.50
35,9
1.42
s
www.honeywell.com/sensing
82,5
3.25
26,1
1.03
82,5
3.25
Flow-through display orientation and transducer location
72,4
2.85
72,4
2.85
PRESSURE RANGE
-14.7 psig to 100 psig
-14.7 psig to 100 psig
-14.7 psig to 100 psig
PRESSURE RANGE
-14.7 psig to 100 psig
PRESSURE RANGE
-14.7 psig to 100 psig
38,1
1.50
38,1
1.50
26,1
1.03
z
35,9
1.42
38,1
1.50
s
CABLE
2 COND
1,8 m (6 ft)
1/4 in. OD 0.035 in. wall, 1/4 in long tube stub
1/4 in. female face seal, swivel
1/4 in. female face seal, swivel
1/4 in. OD 0.035 in. wall, 1/4 in long tube stub
1/4 in. female face seal, swivel
CONNECTIONS
CONNECTIONS
CABLE
2 COND
1,8 m (6 ft)
CV - Transducer at center back,
vertical display orientation
CH - Transducer at center back,
horizontal display orientation
77,0
3.03
42,7
1.68
-40 °C to 85 °C (-40 °F to 185 °F)
1,83 m (6 ft) 2-conductor cable
0 °C to 70 °C (32 °F to 158 °F)
z
38,1
1.50
38,1
1.50
REFERENCE
TLDF4CVT4V100CP
TLDF4CVVFV100CP
TLDF4BSVFV100CP
REFERENCE
TLDF5CVT4V100CP
REFERENCE
TLDS4BNVFV100CP
s
Amplified compensated
12.0 Vdc to 30.0 Vdc
CABLE
2 COND
1,8 m (6 ft)
38,1
1.50
38,1
1.50