CUB5COM1 Red Lion Controls, CUB5COM1 Datasheet

RS485 Serial Communications Card

CUB5COM1

Manufacturer Part Number
CUB5COM1
Description
RS485 Serial Communications Card
Manufacturer
Red Lion Controls
Datasheets

Specifications of CUB5COM1

Accessory Type
RS485 Serial Communications Card
Brand/series
CUB5COM Series
Card Type
RS485 Serial Communications
Data Rate
300 to 19.2 K
Standards
UL Listed, IEC Certified
For Use With
Red Lion CUB5 Miniature Electronic 8-Digit Dual Counters And Rate Indicators
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net
MODEL CUB5 - MINIATURE ELECTRONIC 8-DIGIT DUAL
GENERAL DESCRIPTION
programming to the optional setpoint control and communication capability.
The meter can be programmed as a single or dual counter with rate indication
capability. The display can be toggled either manually or automatically between
the selected displays.
two versions, reflective (CUB5R000) and backlight (CUB5B000). The backlight
version is user selectable for green or red backlighting with variable display
intensity.
including bi-directional and quadrature. When programmed as a dual counter,
each counter has a separate scale factor and decimal points. In the counter/rate
indicator mode, each have their own scaling and decimal point read-outs in
different engineering units. The internal batch counter can be used to count
setpoint output activations.
depending on which operating mode is selected. Input A accepts the signal for
the Count and/or Rate displays, while Input B accepts the signal for the Count
display or direction control. In the anti-coincidence mode, both inputs are
monitored simultaneously so that no counts are lost. The resulting display can
be chosen as the sum or difference of the two inputs. The Rate Indicator has
programmable low (minimum) and high (maximum) update times to provide
optimal display response at any input frequency. There is a programmable user
input that can be programmed to perform a variety of functions.
option cards. Setpoint capability is field installable with the addition of the
single setpoint relay output card or the dual setpoint solid state output card.
Serial communications capability for RS232 or RS485 is added with a serial
option card.
Power Supply (MLPS), which attaches directly to the back of a CUB5. The
MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the
unit and sensors.
DIMENSIONS In inches (mm)
The CUB5 provides the user the ultimate in flexibility, from its complete user
The CUB5 display has 0.46" (11.7 mm) high digits. The LCD is available in
The counter is programmable for one of eight different count modes,
The meter has two separate inputs which provide different functions
The capability of the CUB5 can be easily expanded with the addition of
The CUB5 can be powered from an optional Red Lion Micro-Line/Sensor
C C
U L
R
US LISTED
US LISTED
IND. CONT. EQ.
9876543. 2
SEL
51EB
2.95 (74.9)
RST
1.54 (39.1)
.15 (3.8)
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.
COUNTER AND RATE INDICATOR
.13 (3.3)
(43.4)
1.71
1
COUNTER
Factor to obtain the desired reading for the count display. Input A accepts the
signal for the count and Input B is used for quadrature, dual counter, anti-
coincidence counting, or up/down control counting.
RATE
using a time interval method (1/tau). The unit counts on the negative edge of the
input pulses. After the programmed minimum update time elapses and the next
negative edge occurs, the unit calculates the input rate based on the number of
edges that occurred during the elapsed time. The input rate is then multiplied by
the rate scaling value to calculate the rate display.
minimum update time for the desired response. Extensive scaling capabilities
allow practically any desired reading at very slow count rates.
SAFETY SUMMARY
literature or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
not equipped with safeguards. To do so can be potentially harmful to persons or
equipment in the event of a fault to the meter.
 LCD, REFLECTIVE OR GREEN/RED LED BACKLIGHTING
 0.46" (11.7 mm) HIGH DIGITS
 OPTIONAL SETPOINT OUTPUT CARD
 OPTIONAL SERIAL COMMUNICATIONS CARD (RS232 or RS485)
 OPTIONAL USB PROGRAMMING CARD
 OPERATES FROM 9 TO 28 VDC POWER SOURCE
 PROGRAMMABLE SCALING FOR COUNT AND RATE
 BI-DIRECTIONAL COUNTING, UP/DOWN CONTROL
 QUADRATURE SENSING (UP TO 4 TIMES RESOLUTION)
 BUILT-IN BATCH COUNTING CAPABILITY
 DISPLAY COLOR CHANGE CAPABILITY AT SETPOINT OUTPUT
 NEMA 4X/IP65 SEALED FRONT BEZEL
The CUB5 receives incoming pulses and multiplies them by the Count Scale
The rate indicator utilizes the signal at Input A to calculate the rate value
At slower rates, averaging can be accomplished by programming the rate
All safety related regulations, local codes and instructions that appear in this
Do not use this meter to directly command motors, valves, or other actuators
installationand operation of the unit.
Read complete instructions prior to
1.29 (32.8)
CAUTION: Risk of Danger.
2.68
(68
+.025
-.000
+8
-0
)
1
ON
2
3
ECE
4
CAUTION: Risk of electric shock.
1.30
(33
+.024
-.000
+6
-0
Bulletin No. CUB5-J
Drawing No. LP0584
Released 02/10
)

Related parts for CUB5COM1

CUB5COM1 Summary of contents

Page 1

Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net MODEL CUB5 - MINIATURE ELECTRONIC 8-DIGIT DUAL LISTED US LISTED R IND. CONT. EQ. 51EB GENERAL DESCRIPTION The CUB5 provides the user the ultimate in flexibility, ...

Page 2

... Power frequency magnetic fields Emissions: Emissions Notes: 1. Criterion A: Normal operation within specified limits. Refer to EMC Installation Guidelines for additional information. 12. WEIGHT: 3.2 oz (100 g) 2 PART NUMBER CUB5R000 CUB5B000 CUB5RLY0 CUB5SNK0 CUB5COM1 CUB5COM2 CUB5USB0 MLPS1000 MLPS2000 CBLPROG0 CBPRO007 1 SFCRD200 CBLUSB00 INTENSITY LEVEL TEMPERATURE 1 & 2 -35 to 75° ...

Page 3

O P PTIONAL LUG ADDING OPTION CARDS The CUB5 meters can be fitted with optional output cards and/or serial communications cards. The details for the plug-in cards can be reviewed in the specification section below. The plug-in cards, that are ...

Page 4

I NSTALLING The Plug-in cards are separately purchased option cards that perform specific functions. The cards plug into the main circuit board of the meter. After installing the cards, replace the rear cover before wiring the meter. Comms or ...

Page 5

INPUT WIRING CAUTION: Power common (PWR COMMON) is NOT isolated from input common (INP COMM). In order to preserve the safety of the meter application, the power common must be suitably isolated from hazardous live earth referenced voltage; or ...

Page 6

R EVIEWING THE KEY DISPLAY MODE OPERATION SEL Index display through enabled values RST Resets count display(s) and/or outputs OPERATING MODE DISPLAY DESIGNATORS R “ ” the left of the display is the rate value. - Counter ...

Page 7

MODULE 1-INPUt SEL INP A-b CntA dP CntA ScF CntA rSt Count Counter A Counter A Counter A Mode Decimal Point Scale Factor Reset Action Shaded area selections only apply when Counter B is enabled (Dual ...

Page 8

SCALING FOR COUNT INDICATION The CUB5’s scale factor is factory set provide one count on the display for each pulse that is input to the unit. In many applications, there will not be a one-to-one correspondence between ...

Page 9

SCALING FOR RATE INDICATION To scale the rate, enter a Scaling Display value with a corresponding Scaling Input value. These values are internally plotted to a display value of 0 and input value of 0.0 Hz. A linear relationship is ...

Page 10

MODULE 3-dSPLAY SEL SEL Enb RSt Enb Front Panel Front Panel Display Scroll Display Select Counter Enable Reset Enable FRONT PANEL DISPLAY SELECT ENABLE (SEL)  SEL Enb yES NO  yES yES The selection allows ...

Page 11

MODULE 4-SEtPt SP2 Only SEL SPt SEL SP2 Enb SPn ASN Setpoint Setpoint 2 Select Enable Assignment SPn P-UP SPn tYPE Setpoint Output Setpoint Power-up Boundary State Type The Setpoint Output Parameters are only active when ...

Page 12

SETPOINT OUTPUT TIME-OUT  SPn tOUt 599  001 This parameter is only active if the Setpoint Action is set to time out ( Enter the value in seconds that the Setpoint ...

Page 13

MODULE 5-SEriAL SEL bAUd dAtA Baud Rate Data Bit The Serial Setup Parameters are only active when one of the optional serial communication/programming cards is installed in the meter. Refer to the CUB5USB bulletin for details ...

Page 14

Copy Procedure: 1. Connect the master and receiver using the appropriate copy cable. 2. Apply power to the meters. The receiving meter must be operating in the normal display mode (not programming mode the master meter, enter programming ...

Page 15

... Ready The customer agrees to hold Red Lion Controls harmless from, defend, and indemnify RLC against damages, claims, and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon ...

Page 16

CUB5 PROGRAMMING QUICK OVERVIEW 16 ...