CUB5COM1 Red Lion Controls, CUB5COM1 Datasheet - Page 5

RS485 Serial Communications Card

CUB5COM1

Manufacturer Part Number
CUB5COM1
Description
RS485 Serial Communications Card
Manufacturer
Red Lion Controls
Datasheets

Specifications of CUB5COM1

Accessory Type
RS485 Serial Communications Card
Brand/series
CUB5COM Series
Card Type
RS485 Serial Communications
Data Rate
300 to 19.2 K
Standards
UL Listed, IEC Certified
For Use With
Red Lion CUB5 Miniature Electronic 8-Digit Dual Counters And Rate Indicators
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
4.4 SETPOINT (OUTPUT) WIRING
4.5 SERIAL COMMUNICATION WIRING
4.3 INPUT WIRING
Magnetic Pickup
Current Sinking Output
Switch or Isolated Transistor; Current Sink
SERIAL COMMUNICATIONS PLUG-IN CARD
ON
DUAL SETPOINT N-FET OPEN DRAIN PLUG-IN CARD
ON
1
ON
1
1
2 3
2 3
2 3
Switch position is application dependent.
PWR COMMON
*
PWR COMMON
PWR COMMON
*
*
4
SINGLE SETPOINT RELAY PLUG-IN CARD
*
4
4
*
CAUTION: Power common (PWR COMMON) is NOT isolated from input common (INP COMM). In order to preserve the safety of the meter
application, the power common must be suitably isolated from hazardous live earth referenced voltage; or input common must be at protective earth
ground potential. If not, hazardous voltage may be present at the Signal or User Inputs and input common terminals. Appropriate considerations must
then be given to the potential of the input common with respect to earth ground; and the common of the plug-in cards with respect to input common.
6
COM
COM
RJ11 CONNECTOR PIN OUTS
+9-28 VDC
+9-28 VDC
5
RS485
+9-28 VDC
MAGNETIC PICKUP
4
3
Input A
Input A
2
Input A
OSNK1
OSNK2
1
N.O.
N.C.
NPN
O.C.
AC Inputs From Tach Generators, Etc.
Current Sourcing Output
Switch or Isolated Transistor; Current Source
ON
ON
ON
1 2
6
1 2 3
1 2
5
PWR COMMON
PWR COMMON
*
3
PWR COMMON
*
3
RS232
*
4
*
4
*
4
*
4
3
2
1
Resistor to Limit Current
to 2.5 mA MAX.
5
be wired between OSNK terminal and V+ of the load supply.
4.6 USB PROGRAMMING
+9-28 VDC
+9-28 VDC
Note: Output Common is not isolated from DC Power Common. Load must
+9-28 VDC
AC
Input A
Input A
Input A
USB PROGRAMING PLUG-IN CARD
PNP
O.C.
COM
ELECTRICAL CONNECTIONS
ELECTRICAL CONNECTIONS
Shaded areas not recommended for counting applications.
Two Wire Proximity, Current Source
Interfacing With TTL
Current Sink Output; Quad/Direction
ON
1
ON
ON
1
2 3
1 2 3
2 3
PWR COMMON
PWR COMMON
*
PWR COMMON
*
4
N.O.
*
4
4
(30 V MAX.)
2.2 k Ω
OSNK 1(2)
COM
N.C.
+9-28 VDC
+9-28 VDC
+9-28 VDC
Input A
Input A
+5 V
COMMON

Related parts for CUB5COM1