CUB5COM1 Red Lion Controls, CUB5COM1 Datasheet - Page 3

RS485 Serial Communications Card

CUB5COM1

Manufacturer Part Number
CUB5COM1
Description
RS485 Serial Communications Card
Manufacturer
Red Lion Controls
Datasheets

Specifications of CUB5COM1

Accessory Type
RS485 Serial Communications Card
Brand/series
CUB5COM Series
Card Type
RS485 Serial Communications
Data Rate
300 to 19.2 K
Standards
UL Listed, IEC Certified
For Use With
Red Lion CUB5 Miniature Electronic 8-Digit Dual Counters And Rate Indicators
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ADDING OPTION CARDS
communications cards. The details for the plug-in cards can be reviewed in the
specification section below. The plug-in cards, that are sold separately, can be
installed initially or at a later date.
DUAL SINKING OUTPUT CARD (One or two setpoints)
INSTALLATION
unit is intended to be mounted into an enclosed panel. Prepare the panel
cutout to the dimensions shown. Remove the panel
latch from the unit. Slide the panel gasket over the
rear of the unit to the back of the bezel. The unit
should be installed fully assembled. Insert the unit
into the panel cutout.
latch over the rear of the unit so that the tabs of
below. A bank of 4 switches is located in the upper right hand corner. After
setting the switches, install any optional plug-in cards before replacing the rear
cover (see next section).
REMOVING THE REAR COVER
input terminals. To release the tab, insert a small, flat blade screwdriver between
the tab and the plastic wall below the terminals. Inserting the screwdriver will
provide enough pressure to release the tab locks. To replace the cover, align the
cover with the input terminals and press down until the cover snaps into place.
O
1.0 I
2.0 S
The CUB5 meters can be fitted with optional output cards and/or serial
Type: Single FORM-C relay
Isolation To Sensor & User Input Commons: 1400 Vrms for 1 min.
Contact Rating: 1 amp @ 30 VDC resistive; 0.3 amp @ 125 VAC resistive
Life Expectancy: 100,000 minimum operations
Response Time:
Type: Non-isolated switched DC, N Channel open drain MOSFET
Current Rating: 100 mA max.
The meter meets NEMA 4X/IP65 requirements when properly installed. The
While holding the unit in place, push the panel
To access the switches, remove the rear cover of the meter as described
To remove the rear cover, locate the cover locking tab below the 2nd and 3rd
Working Voltage: 150 Vrms
Turn On Time: 4 msec. max.
Turn Off Time: 4 msec. max.
PTIONAL
Warning: Exposed line voltage exists on the circuit boards. Remove
WARNING: Disconnect all power to the unit before installing
SINGLE RELAY OUTPUT CARD (One setpoint only)
BEZEL
PANEL
GASKET
all power to the meter and load circuits before accessing inside of
the meter.
Plug-in card.
NSTALLING THE
ETTING THE
P
PANEL
LUG
-
NUT FASTENER
IN
DIP S
MOUNTING CLIP
MOUNTING SCREW
C
M
ARDS
ETER
WITCHES
3
RS485 SERIAL COMMUNICATIONS CARD
RS232 SERIAL COMMUNICATIONS CARD
USB PROGRAMMING CARD
the panel latch engage in the slots on the case. The panel latch should be
engaged in the farthest forward slot possible. To achieve a proper seal, tighten
the latch screws evenly until the unit is snug in the panel (Torque to approx. 28
to 36 in-oz [0.202 to 0.26 N-m]). Do not over-tighten the screws.
INSTALLATION ENVIRONMENT
temperature and provides good air circulation. Placing the unit near devices that
generate excessive heat should be avoided.
Do NOT use solvents. Continuous exposure to direct sunlight may accelerate the
aging process of the bezel.
keypad of the unit.
SETTING THE INPUT DIP SWITCHES
before applying power.
SWITCH 1
SWITCH 2
SWITCHES 3 and 4
V
V
Offstate Leakage Current: 0.5 mA max.
Type: RS485 multi-point balanced interface (non-isolated)
Baud Rate: 300 to 38.4k
Data Format: 7/8 bits; odd, even, or no parity
Bus Address: 0 to 99; max 32 meters per line
Transmit Delay: Selectable, 2 msec min. or 50 msec min.
Type: RS232 half duplex (non-isolated)
Baud Rate: 300 to 38.4k
Data Format: 7/8 bits; odd, even, or no parity
Type: USB virtual comms port
Connection: Type B
Baud Rate: 300 to 38.4k
Unit Address: 0 to 99
The unit should be installed in a location that does not exceed the operating
The bezel should only be cleaned with a soft cloth and neutral soap product.
Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the
The meter has four DIP switches for Input A and Input B that must be set
LOGIC: Input A trigger levels V
MAG: 200 mV peak input sensitivity; 100 mV
SNK.: Adds internal 7.8 K pull-up resistor to +9 to
SRC.: Adds internal 3.9 K pull-down resistor,
HI Frequency: Removes damping capacitor and allows max. frequency.
LO Frequency: Adds a damping capacitor for switch contact bounce. Limits
DS ON
DS MAX
V
hysteresis; maximum input voltage: 40 V peak
(28 Vrms); Must also have SRC switch ON.
(Not recommended with counting applications.)
28 VDC, I
7.2 mA max. @ 28 VDC max.
input frequency to 50 Hz and input pulse widths to 10 msec.
IH
: 0.7 V @ 100 mA
= 2.75 V min.; V
: 30 VDC
MAX
= 3.8 mA.
2.68
(68
MAX
+.8
-.0
+.025
-.000
)
= 28 VDC
IL
= 1.25 V max.;
1.30
(33
+.6
-.0
+.024
-.000
)
ON
1
Factory Setting
2
3
4