Specifications of 34410A

Dmm Type
Bench
Voltage Measuring Range Dc
100mV To 1000V
Voltage Measuring Range Ac
100mV To 750V
Current Measuring Range Dc
100µA To 3A
Current Measuring Range Ac
100µA To 3A
Lead Free Status / RoHS Status
na
System readings and
throughput rates
The 34410A and 34411A have
excellent programming and
data retrieval performance.
This performance is exhibited
in the tables below, which are
straight from the data sheet.
There are three paths described
in the system reading architec-
ture diagram. See Figure 11.
• Path A – this is the reading
Figure 11. System Reading Architecture
rate into reading storage.
Top speed into memory is
50,000 readings/s, which
is a function of the A-to-D
sampling rate. Any measure-
ment – DC or AC – will
generate a pulse on the
voltmeter complete signal
of the DMM. That signal
can be used to measure all
sample rates on a scope
or frequency counter.
• Path B – this is the time it
• Path C – this is the time it
DMM memory to PC (Maximum reading rate out of memory)
Drawing – Path B
Reading
Format
ASCII
32-bit Binary
64-bit Binary
Direct I/O Measurements (Single reading – measure and I/O time)
Drawing – Path C
Function
DCV/2-wire
Resistance
ACV/
Frequency
1
1/2 scale input signal, immediate trigger, trigger delay 0, auto-zero off, auto-range off, no math, null off,
60 Hz line frequency, Specifications are for 34410A or (34411A). See manual for performance on other functions.
takes to retrieve readings
from reading storage (DMM
memory to PC). This speed
is dependent both upon the
data format and the interface.
Data format can be ASCII
(15 bytes), binary 32 (4 bytes),
or binary 64 (8 bytes). Inter-
faces include the physical
interfaces of GPIB, LAN,
and USB 2.0, and also
LAN: VXI-11 or sockets.
takes to programmatically
trigger a reading (or readings)
and retrieve the results into
a computer. Single reading
0.006 (0.001)
1 ms Gate
Fast Filter
Readings/s
Resolution
(NPLC)
89,000
47,000
GPIB
2,850
17
GPIB
10.0
ms
3.0
Readings/s
USB 2.0
265,000
154,000
2,000
USB 2.0
10.0
3.6
ms
• Since the data rates are so fast
times are shown in the direct
I/O table and represent a
“READ?” command, which is
the same as the
“INIT;:FETCH?” command.
when you use binary format,
the PC can keep up with any
sample rate by simply issuing
requests for blocks of readings
at periodic times while making
continuous measurements at
up to 50,000 readings/s rate.
Only two modes are not fast
enough to keep up with
50,000 readings/s: ASCII and
64-bit binary over GPIB.
(VXI-11)
10.0
5.0
LAN
ms
LAN (VXI-11)
Readings/s
1
110,000
60,000
4,800
1
(Sockets)
10.0
LAN
3.5
ms
Maximum Reading
Rate into Memory
or to Direct I/O
(Readings/secs)
Drawing – Path A or C
10,000 (50,000)
LAN (Sockets)
Readings/sec
270,000
160,000
4,000
500