9015 JEWELL / MODUTEC, 9015 Datasheet - Page 16

MULTIMETER DIGITAL HANDHELD, 3-1/2 DIGIT

9015

Manufacturer Part Number
9015
Description
MULTIMETER DIGITAL HANDHELD, 3-1/2 DIGIT
Manufacturer
JEWELL / MODUTEC
Datasheet

Specifications of 9015

Dmm Type
Handheld
Voltage Measuring Range Dc
1000
Voltage Measuring Range Ac
750
Current Measuring Range Dc
2mA To 10A
Current Measuring Range Ac
20mA To 10A
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
9015
Manufacturer:
ST
0
Part Number:
9015
Manufacturer:
CJ/长电
Quantity:
20 000
Part Number:
90151-2114
Manufacturer:
MOLEX
Quantity:
12 000
Part Number:
90151-2116
Manufacturer:
MOLEX
Quantity:
42 144
Part Number:
90151-2116
Manufacturer:
MOLEX
Quantity:
35 000
Part Number:
901512104
Manufacturer:
Molex, LLC
Quantity:
201
Part Number:
901512106
Manufacturer:
Molex, LLC
Quantity:
184
7.4.3 Connect the test probes to circuit being measured. The LCD will display
7.4.4 If the display indicates overrange, i.e. “1- - -”, disconnect the test probes
7.4.5 If the displayed value is less than “200” (decimal point not shown), a more
7.5 DC Current Measurement:
7.5.1 Connect the black test lead to the COM jack. Connect the red test lead to
7.5.2 If the red test lead is inserted into the 10A jack, set the RANGE switch to
7.5.3 If the red test lead is inserted into the mA jack, set the RANGE switch
If the magnitude of the current to be measured is unknown, always start
by setting the meter to the highest range, and then to lower ranges,
Do not rotate the RANGE switch with the input applied to the meter.
If the input current is higher than 10A, do not attempt to measure!
If the current is less than 200mA, connect the red test lead to the mA jack.
the 10A jack unless it is known that the input current is less than 200mA.
the 10A
to the 200mA
accurate reading may be obtained by setting the RANGE switch to a lower
switch to the next lower position. Reconnect the test probes to the circuit
the AC voltage.
from the circuit and rotate the RANGE switch to the next higher position.
Reconnect the test probes to the circuit and observe the reading on the
LCD display. If the RANGE switch is already at the highest position
(i.e. 750 VAC), the input voltage exceeds the measurement capability
of the meter and should not be measured.
range. Disconnect the probes from the circuit and rotate the RANGE
and observe the reading on the LCD display. If the RANGE switch is
already on the lowest position (i.e. 2V AC), no greater measurement
resolution can be obtained.
Use caution when measuring current in a circuit with voltages
above 50 VDC. Do not use meter to measure current in
circuits whose voltage exceeds 250V AC/DC.
position. Read the value of the current on the LCD display.
until a satisfactory reading is obtained.
position. Read the value of the current on the LCD.
WARNING!!!