108995180 Lineage Power, 108995180 Datasheet - Page 15

no-image

108995180

Manufacturer Part Number
108995180
Description
Module DC-DC 1-OUT 0.75V to 3.63V 16A 6-Pin SMT T/R
Manufacturer
Lineage Power
Type
Non-Inverting|Inverting|Step Up|Step Downr
Datasheet

Specifications of 108995180

Package
6SMT
Output Current
16 A
Output Voltage
0.75 to 3.63 V
Input Voltage
3 to 5.5 V
Number Of Outputs
1
Data Sheet
October 2, 2009
Thermal Considerations
Power modules operate in a variety of thermal
environments; however, sufficient cooling should always
be provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of the
module will result in an increase in reliability. The thermal
data presented here is based on physical measurements
taken in a wind tunnel. The test set-up is shown in Figure
34. Note that the airflow is parallel to the short axis of the
module as shown in figure 33. The derating data applies
to airflow in either direction of the module’s short axis.
Figure 33. T ref Temperature measurement location.
The thermal reference point, T
specifications is shown in Figure 33. For reliable
operation this temperature should not exceed 115
The output power of the module should not exceed the
rated power of the module (Vo,set x Io,max).
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
LINEAGE
POWER
Bottom View
Top View
ref
3.0 – 5.5Vdc input; 0.75Vdc to 3.63Vdc Output; 16A output current
Air Flow
used in the
T
ref
Austin Superlynx
o
C.
Wind T unnel
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device temperatures.
Heat Transfer via Convection
Increased airflow over the module enhances the heat
transfer via convection. Thermal derating curves showing
the maximum output current that can be delivered at
different local ambient temperatures (T
conditions ranging from natural convection and up to
2m/s (400 ft./min) are shown in the Characteristics
Curves section.
Layout Considerations
Copper paths must not be routed beneath the power
module. For additional layout guide-lines, refer to the
FLTR100V10 application note.
Figure 34. Thermal Test Set-up.
PWBs
TM
SMT Non-isolated Power Modules:
flow
Air
(0.235)
x
5.97_
(3.0)
76.2_
25.4_
(1.0)
A
) for airflow
Probe Location
for measuring
airflow and
ambient
temperature
Power Module
15