CC109112042 Lineage Power, CC109112042 Datasheet - Page 15

no-image

CC109112042

Manufacturer Part Number
CC109112042
Description
Module DC-DC 1-OUT 5V 10A 8-Pin 1/16-Brick T/R
Manufacturer
Lineage Power
Type
Step Downr
Datasheet

Specifications of CC109112042

Package
81/16-Brick
Output Current
10 A
Output Voltage
5 V
Input Voltage
48 V
Number Of Outputs
1
Data Sheet
December 15, 2009
Feature Descriptions
The voltage between the Vo(+) and Vo(–) terminals
must not exceed the minimum output overvoltage
protection value shown in the Feature Specifications
table. This limit includes any increase in voltage due
to remote-sense compensation and output voltage
set-point adjustment trim.
Although the output voltage can be increased by both
the remote sense and by the trim, the maximum
increase for the output voltage is not the sum of both.
The maximum increase is the larger of either the
remote sense or the trim. The amount of power
delivered by the module is defined as the voltage at
the output terminals multiplied by the output current.
When using remote sense and trim, the output
voltage of the module can be increased, which at the
same output current would increase the power output
of the module. Care should be taken to ensure that
the maximum output power of the module remains at
or below the maximum rated power (Maximum rated
power = Vo,set x Io,max).
Thermal Considerations
The power modules operate in a variety of thermal
environments; however, sufficient cooling should be
provided to help ensure reliable operation.
Considerations include ambient temperature, airflow,
module power dissipation, and the need for increased
reliability. A reduction in the operating temperature of
the module will result in an increase in reliability. The
thermal data presented here is based on physical
measurements taken in a wind tunnel.
The thermal reference point, T
specifications is shown in Figure 43. For reliable
operation this temperature should not exceed 120
Figure 43. T
Locations.
Please refer to the Application Note “Thermal
Characterization Process For Open-Frame Board-
Mounted Power Modules” for a detailed discussion of
thermal aspects including maximum device
temperatures.
LINEAGE
POWER
ref
Temperature Measurement
ref
(continued)
used in the
36 – 75Vdc Input; 1.2 to 5.0Vdc Output; 10 to 25A Output current
o
C.
KW010/015/020/025 Series Power Modules:
EMC Considerations
The KW series modules are designed to meet the
conducted emission limits of EN55022 class A with no
filter at the input of the module. The module shall
also meet limits of EN55022 Class B with a
recommended single stage filter. Please contact your
Lineage Power Sales Representitive for further
information.
Figure 44. KW015A0F Quasi Peak Conducted
Emissions with EN 55022 Class A limits, no
external filter (V
Figure 45. KW015A0F Average Conducted
Emissions with EN 55022 Class A limits, no
external filter (V
+
80
70
60
50
40
30
20
10
80
70
60
50
40
30
20
10
Level [dBµV]
Level [dBµV]
0
0
150k
150k
MES CE0921041009_pre PK
LIM EN 55022A V QP
MES CE0921041009_fin AV
MES CE0921041009_pre AV
LIM EN 55022A V AV
300k
300k
500k
+
500k
Voltage QP Limit
Voltage AV Limit
IN
IN
= V
= V
1M
Frequency [Hz]
1M
Frequency [Hz]
IN,NOM
IN,NOM
2M
2M
, I
, I
o
o
3M
3M
= 0.85 I
= 0.85 I
5M
5M
7M
o,max
o,max
7M
10M
10M
).
).
30M
15
30M

Related parts for CC109112042