CC109112042 Lineage Power, CC109112042 Datasheet - Page 2

no-image

CC109112042

Manufacturer Part Number
CC109112042
Description
Module DC-DC 1-OUT 5V 10A 8-Pin 1/16-Brick T/R
Manufacturer
Lineage Power
Type
Step Downr
Datasheet

Specifications of CC109112042

Package
81/16-Brick
Output Current
10 A
Output Voltage
5 V
Input Voltage
48 V
Number Of Outputs
1
December 15, 2009
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an
integrated part of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included,
however, to achieve maximum safety and system protection, always use an input line fuse. The safety agencies
require a time-delay fuse with a maximum rating of 5 A (see Safety Considerations section). Based on the
information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a
lower rating can be used. Refer to the fuse manufacturer’s data sheet for further information.
LINEAGE
Parameter
Input Voltage
Operating Ambient Temperature
Storage Temperature
I/O Isolation voltage (100% Factory Hi-Pot tested)
Parameter
Operating Input Voltage
Maximum Input Current
(V
Input No Load Current
Input Stand-by Current
Inrush Transient
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
V
Input Ripple Rejection (120Hz)
EMC, EN55022
Continuous
Transient (100 ms)
(see Thermal Considerations section)
IN, max,
(V
(V
IN
= V
IN
IN
= V
= V
IN, min
I
O
= I
IN, nom
IN, nom
POWER
Omax
to V
, I
, module disabled)
; See Test configuration section)
IN, max
O
= 0, module enabled)
, I
O
=I
O, max
)
36 – 75Vdc Input; 1.2 to 5.0Vdc Output; 10 to 25A Output current
IN, min
to
Device
All
All
All
All
All
All
All
Device
All
All
All
All
All
Symbol
I
I
IN,stand-by
IN,No load
I
IN,max
V
I
Symbol
2
IN
t
V
IN,trans
T
V
T
stg
IN
A
See EMC Considerations section
Min
36
50
Min
-0.3
-0.3
-40
-55
Typ
1.7
48
55
30
60
5
1500
Max
100
125
80
85
Max
100
2.0
0.1
75
7
mA
Unit
Vdc
Vdc
Vdc
Unit
°C
°C
mA
mA
A
V
A
dB
p-p
2
dc
dc
s
2

Related parts for CC109112042