9-1393792-9 Tyco Electronics, 9-1393792-9 Datasheet - Page 416

no-image

9-1393792-9

Manufacturer Part Number
9-1393792-9
Description
Electromechanical Relay DPDT 3A 24VDC 2.88KOhm Through Hole
Manufacturer
Tyco Electronics
Type
Signal Relayr
Datasheet

Specifications of 9-1393792-9

Contact Arrangement
DPDT
Dc Coil Voltage
24 V
Coil Current
8.33 mA
Mounting
Through Hole
1216
Timer Function Descriptions
Time Base:
.1 M = 1/10 Minutes
10 H = 10 Hours
Dimensions are shown for
reference purposes only.
See functional explanation for details.
.1 H = 1/10 Hours
.1 S = 1/10 Seconds
M = Minutes
H = Hours
S = Seconds
LED to show time status.
3
000 TO 999
TIME SET
1
REPEAT
ONE SHOT
OFF DELAY
INTERVAL
ON DELAY
2
Timing Range 0.1 to 99.9 Seconds
Timing Range 1 to 999 Seconds
Timing Range 0.1 to 99.9 Minutes
Timing Range 1 to 999 Minutes
Timing Range 0.1 to 99.9 Hours
Timing Range 1 to 999 Hours
Timing Range 10 to 9990 Hours
S
BASE
TIME
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Catalog 1308242
Repeat: Output relay is turned on at end of programmed time interval which is
started by application of input power. Relay stays on for equal time interval, then
turns off and cycle is repeated on a free-running basis with equal on and off times
until terminated by removal of input power. LED is flashing when output relay is
off and on continuously when the relay is on. Applying CONTROL input during
timing will have no effect on timing or the state of the relay.
One Shot: Output relay is turned on by applying CONTROL input with input
voltage present or application of input voltage with the CONTROL input on.
Immediately upon either, timing is initiated with the output relay turning off at the
completion of the selected time interval. Applying CONTROL input after time out
will reset the timer, turn on the output relay and initiate another time interval. LED
is on continuously when output relay is off and flashes when the relay is on.
Applying CONTROL input during timing will have no effect on timing or the state
of the relay.
Off Delay: Output relay is turned on by applying CONTROL input with input
voltage present or application of input voltage with the CONTROL input on. The
time interval will be started by removing the CONTROL input with the output relay
turning off at completion of the time interval. Reapplying the CONTROL during
timing will reset the time to zero and inhibit timing until removed. LED is off when
CONTROL input is on, flashing during timing and on continuously when the output
relay is off.
Interval: Output relay is turned on for a programmed time interval by applying
input voltage. LED flashes when output relay is on and is on continuously when
the output relay is off. Applying CONTROL input will have no effect on timing or
the state of the relay.
On Delay: Output relay is off for a programmed time interval which is started by
applying input voltage. LED flashes when output relay is off and is on continuously
when the output relay is on. Applying CONTROL input will have no effect on timing
or the state of the relay.
Issued 3-03
Specifications and availability
subject to change.
www.tycoelectronics.com