2-1419130-4 TE Connectivity, 2-1419130-4 Datasheet - Page 358

no-image

2-1419130-4

Manufacturer Part Number
2-1419130-4
Description
Electromechanical Relay SPDT 1A 12VDC 960Ohm Through Hole
Manufacturer
TE Connectivity
Type
Miniature Sealed Relayr
Datasheets

Specifications of 2-1419130-4

Contact Arrangement
SPDT
Dc Coil Voltage
12 V
Coil Current
12.5 mA
Mounting
Through Hole
Relay Construction
Non-Latching
Coil Voltage Dc
12V
Contact Form
1 Form C
Coil Resistance
960Ohm
Contact Current Rating
1A
Contact Material
Silver Nickel/Gold Plated
Coil Suppression Diode
No
Push To Test Button
No
Led Indicator
No
Seal
Sealed
Product Height (mm)
10mm
Product Depth (mm)
7.5mm
Product Length (mm)
12.5mm
Mounting Style
Through Hole
Termination Style
PC Pin
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2-1419130-4
Manufacturer:
TE
Quantity:
39 178
Part Number:
2-1419130-4
Manufacturer:
TE/AMP
Quantity:
35 000
1010
Our authorized distributors are more likely to maintain the following items in stock for immediate delivery.
None at present.
Dimensions are shown for
reference purposes only.
Ordering Information
Application Information
Load Polarity: VKP series relays for flashing lamp applications are
constructed with Palladium-Copper movable contacts and fine grain silver
stationary contacts. This causes the relay to be sensitive to the polarity of
the load voltage. This type of VKP relay must be mechanized in the circuit
such that the more positive connection is made to the movable contact
(identified as terminal 4 in the wiring diagrams). Failure to do so will nullify
the benefit of the Palladium Copper and will result in contact welding.
Typical Applications: VKP series relays for flashing lamp applications are
typically used for turn signal, hazard warning, emergency vehicle, and
security system applications. They may also be used for high in-rush
current capacitive loads such as audio amplifiers. Use on inductive loads or
loads with high continuous load currents should be avoided. The relay
should also not be used for applications which do not have a significant
make current as high contact voltage drop may result.
Standard Current Relays: VKP series relays for flashing lamp applications
which are indicated as “standard current” units are generally suitable for
passenger car and light truck applications for turn signal, hazard warning, or
combination flashers (with or without normal trailering requirements) for 2
or 3 bulb turn signal systems. They are also generally suitable for security
system applications for lamp flashing and for most audio amplifier
applications.
High Current Relays: VKP series relays for flashing lamp applications
which are designated as “high current” have larger contacts, a larger shunt
connecting the movable contacts to the output terminals, and other
performance enhancing characteristics to provide longer life and provide
higher current carrying capacity. This type relay should be used for truck
applications which have greater load current and in applications such as
emergency vehicle lighting and service vehicle hazard warning lights which
have very high cycle life requirements . The high current versions are also
recommended for most alternating flasher applications, as this version has
much improved performance of the normally closed contact. However,
optimum life can be obtained for alternating applications by using two
normally open relays and powering the coils alternately.
Figure 2 – Ambient Temperature vs. Coil Voltage for Continuous Flashing at 50% Duty Cycle (Steady Current, Open Style)
Consult factory.
*Standard Coil Voltages: F = 12VDC
VKP-11 * 32
VKP-11 * 62
VKP-15 * 62
VKP-31 * 32
VKP-31 * 62
VKP-35 * 62
Part Number
H = 24VDC (Consult factory for availability)
Arrangement
1 Form A
1 Form A
1 Form C
1 Form A
1 Form A
1 Form C
Contact
Dimensions are in inches over
(millimeters) unless otherwise
specified.
PdCu/AgNi 0.15
PdCu/AgNi 0.15
PdCu/AgNi 0.15
PdCu/AgNi 0.15
PdCu/AgNi 0.15
PdCu/AgNi 0.15
Catalog 1308242
Material
Contact
Issued 3-03
Specifications and availability
subject to change.
Electrical Life Test Information
Standard Current Relays: 3 bulb T/S (turn signal) system, combined turn
signal and hazard warning with normal trailering (test requirements):
This application represent about the limit of the performance capability of
the “standard current” types and is generally the limit of the industry
requirement for passenger car applications.
Note: Bulb as used here is a 27 watt turn signal bulb, trade #1156. Testing includes operations
at -40°C, 23°C, and 85°C.
High Current Relays: 3 bulb T/S system, combined turn signal and hazard
warning with special trailering (test requirements):
This application represent about the limit of the performance capability of
the “high current” types. It should be noted that the low current operations
have very little affect on the total product life where as the 14 bulb (33
ampere) operations are extremely destructive. Units test on 14 bulb (only)
loads can be expected to fail at less than 1 million operations.
Note: Bulb as used here is a 27 watt turn signal bulb, trade #1156. Testing includes operations
at -40°C, 23°C, and 85°C.
Design Considerations: It should be noted that although the VKP series
relays are capable of handling relatively high currents, when applying the
product under high current and high ambient temperature conditions,
providing adequate conductor volume is critical, as is the solder
connection, particularly with respect to the normally open contact terminal.
It may be necessary to use high temperature solder, a plated through hole
PCB, or a copper lead frame type construction under these conditions to
prevent failure of the solder joint.
3 bulb
4 bulb
6 bulb
8 bulb
TOTAL
3 bulb
6 bulb
7 bulb
14 bulb
TOTAL
Immersion Cleanable Case
Immersion Cleanable Case
Immersion Cleanable Case
Enclosure
1.8 million operations
130 K operations
194 K operations
248 K operations
2.3 million operations
2.1 million operations
194 K operations
259 K operations
497 K operations
3.0 million operations
Open
Open
Open
TYCO ELECTRONICS
Standard Current
Standard Current
Load Ratings
High Current
High Current
High Current
High Current
www.tycoelectronics.com
Technical support:
Refer to inside back cover.

Related parts for 2-1419130-4