SI3206-B-GQ Silicon Laboratories Inc, SI3206-B-GQ Datasheet - Page 76

no-image

SI3206-B-GQ

Manufacturer Part Number
SI3206-B-GQ
Description
IC PROSLIC LINE FEED 125V 48TQFP
Manufacturer
Silicon Laboratories Inc
Series
ProSLIC®r
Datasheets

Specifications of SI3206-B-GQ

On-hook Transmission
Yes
Polarity Reversal
Yes
On-chip Ring Relay Driver
Yes
Longitudinal Balanced
63
Operating Supply Voltage (typ)
3.3V
Operating Temp Range
-40C to 85C
Package Type
TQFP
Loop Current Limit
45mA
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Function
Subscriber Line Interface Concept (SLIC)
Interface
GCI, PCM, SPI
Number Of Circuits
4
Voltage - Supply
3.3V
Current - Supply
*
Power (watts)
*
Operating Temperature
*
Mounting Type
Surface Mount
Package / Case
48-TQFP Exposed Pad
Includes
*
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI3206-B-GQ
Manufacturer:
SILICON
Quantity:
240
Part Number:
SI3206-B-GQ
Manufacturer:
Silicon Laboratories Inc
Quantity:
10 000
Part Number:
SI3206-B-GQ
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Si3232
LINEFEED: Linefeed Control (Register Address 6)
(Register type: Operational)
Reset settings = 0x00
76
Name
Type
Bit
6:4
2:0
Bit
7
3
Reserved
Reserved
LFS[2:0]
LF[2:0]
Name
D7
D6
Read returns zero.
Linefeed Shadow.
This register reflects the actual realtime linefeed status. Automatic operations may cause
actual linefeed state transitions regardless of the Linefeed register settings (e.g., when
the Linefeed register is in the ringing state, the Linefeed Shadow register will reflect the
ringing state during ringing bursts and the OHT state during silent periods between ring-
ing bursts).
000 = Open
001 = Forward Active
010 = Forward On-hook Transmission (OHT)
011 = TIP Open
100 = Ringing
101 = Reverse Active
110 = Reverse On-hook Transmission
111 = RING Open
Read returns zero.
Linefeed.
Writing to this register sets the linefeed state.
000 = Open
001 = Forward Active
010 = Forward On-hook Transmission (OHT)
011 = TIP Open
100 = Ringing
101 = Reverse Active
110 = Reverse On-hook Transmission
111 = RING Open
LFS[2:0]
D5
R
Preliminary Rev. 0.96
D4
D3
Function
D2
LF[2:0]
R/W
D1
D0

Related parts for SI3206-B-GQ