HIP0081AS1 Intersil, HIP0081AS1 Datasheet
HIP0081AS1
Specifications of HIP0081AS1
Available stocks
Related parts for HIP0081AS1
HIP0081AS1 Summary of contents
Page 1
... Steppers - Power Output - Motors - Lamps - Displays Ordering Information TEMP. PART NUMBER RANGE ( HIP0081AS1 -40 to 125 HIP0081AS2 -40 to 125 HIP0080AM -40 to 125 CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. | Intersil and Design is a trademark of Intersil Corporation. File Number 3018 ...
Page 2
Pinouts HIP0081 (SIP) TOP VIEW HEAT SINK TAB AT SAME POTENTIAL AS PIN 8-GND Functional Block Diagram SWITCH/CHANNELS V 100k IN1 DR1-CNTL POR CS CONTROL AND 16-BIT CLK DATAOUT DO DATAIN ENABLE (NOTE) POWER DOWN SWITCH 100k ...
Page 3
Functional Signal Flow Diagram DATAIN (DI CLK ENABLE (EN) LOW IDLE CURRENT POWER DOWN SWITCH 3 HIP0080, HIP0081 SWITCH/CHANNELS (SEE FUNCTIONAL BLOCK DIAGRAM) IN1 DR1 CNTL (DATAPATH) 4 IN2 DR2 CNTL (DATAPATH) 4 IN3 DR3 ...
Page 4
Absolute Maximum Ratings Supply Voltage (Logic and Control -16 to 45V Power MOSFET Drain Voltage (Note -0.5 ...
Page 5
Electrical Specifications V = 5.5V to 25V 5 PARAMETER SYMBOL HIP0080 Output Off I OFF Current HIP0080 Output Leakage I OFFLK Current Over-Voltage Clamp Range V CLAMP Current Short Circuit Prot. I OUT(SC) Short Circuit Det. Delay t ...
Page 6
Diagnostic Interface Overview Each Quad Inverting Power Driver IC may be used as a single power switching driver, with or without the diagnostic interface. Where more than 4 Power Driver Switches are required, the HIP0080 or HIP0081 may be used ...
Page 7
DO. The fault action that sets each of the diagnostics bits for each of the 4 switches is described below: Bit 1 - indicates a thermal overload when the sensed ...
Page 8
OUTPUTS AND 4 BITS PER OUTPUT 4 POR 16-BIT PARALLEL RESET CLK DIAG. DATA REG. LOGIC CLK START OF 16 DIAGNOSTIC DATA BITS GATE OT1 SB1 SG1 OI1 ERROR FLAG BIT ...
Page 9
HIP0080 SINGLE PULSE ENERGY vs TIME AMB NOTE: SAFE OPERATING AREA BELOW DOTTED LINE 10000 1000 100 0 PULSE WIDTH TIME (ms) FIGURE 4. SINGLE PULSE ENERGY TEST SHOWING THE FAILURE BOUNDARY FOR ...
Page 10
The Junction-to-Ambient equivalent to Equation – Not all Integrated Circuit packages have a directly definable case temperature because the ...
Page 11
CURVE (3): r 0.5 (4) CURVE (4): r THERMAL RESISTANCE, 0 CASE (HEAT SINK TAB) TEMPERATURE ( FIGURE 7. HIP0081 CURRENT vs CASE (TAB) TEMPERATURE, ALL OUTPUTS ON WITH EQUAL CURRENT ...
Page 12
Single-In-Line Plastic Packages (SIP) D SEE TAB -X- DETAIL E E1 -Y- TERMINAL R1 N TERMINAL # 0.010(0.25 ...
Page 13
Single-In-Line Plastic Packages (SIP) -X- D Ø TYP 0.010 LEAD TIPS 0.814 0.407 OF 0.150 C L 0.030 TYP 0.050 TYP ...
Page 14
... Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use ...