CUB50000 Red Lion Controls, CUB50000 Datasheet - Page 2

COUNTER/RATE INDICATOR RELFECT

CUB50000

Manufacturer Part Number
CUB50000
Description
COUNTER/RATE INDICATOR RELFECT
Manufacturer
Red Lion Controls
Series
CUB5r
Datasheet

Specifications of CUB50000

Count Rate
20kHz
Number Of Digits/alpha
8
Input Type
Voltage
Voltage - Supply
9 V ~ 28 V
Display Type
LCD Non-Backlit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Other names
Q517088
RLC500
SPECIFICATIONS (Cont’d)
6. FRONT PANEL BUTTONS:
7. COUNT DISPLAY: 8-digit with positive count, 7-digit with minus sign
8. RATE DISPLAY: 6 digits with an annunciator “R” on the left hand side of
10. RATE MINIMUM INPUT FREQUENCY: 0.01 Hz
11. RATE MAXIMUM FREQUENCY: 10 KHz
12. MAXIMUM COUNT RATES:
13. ENVIRONMENTAL CONDITIONS:
14. CERTIFICATIONS AND COMPLIANCES:
15. CONSTRUCTION: High impact plastic case with clear viewing window.
16. WEIGHT: 3 oz (85 grams)
BASIC OPERATION
and then the unit displays its revision level. If all P’s appear in the display, press
the select (SEL) button and check all of the data setups.
single counter with rate indication or dual counters with rate indication.
9. RATE ACCURACY: 0.05%
Immunity to EN 50082-2
Electrostatic discharge
Electromagnetic RF fields
Fast transients (burst)
RF conducted interference
Simulation of cordless telephone
Emissions to EN 50081-2
RF interference
SELECT: Toggles display in the normal operating mode if enabled.
RESET: Resets counter to zero in the normal operating mode if enabled.
indication for negative count and the display flashes “tot OVEr” for an
overflow condition. Dual count mode only, “B” counter, seven digit positive
count: “btot OVEr” appears for an overflow condition.
the LCD.
Overflow Indication: “R OLOLOL” appears when max. display digits are
Operating Temperature: 0 to 60°C (above 50°C, derate backlight operating
Storage Temperature: -30 to 85°C
Operating and Storage Humidity: 85% max. (non-condensing) from 0°C
Altitude: Up to 2000 meters
SAFETY
ELECTROMAGNETIC COMPATIBILITY
Refer to EMC Installation Guidelines for additional information.
When power is applied to the unit, it performs an internal self-diagnostic test
The CUB5 can be programmed to function as a single counter, dual counters,
The front panel meets NEMA 4X/IP65 requirements for indoor use when
properly installed. Installation Category I, Pollution Degree 2. Panel gasket
and mounting clip included.
Advances menu selection in programming mode.
Changes data in programming mode.
exceeded.
voltage to 24 VDC max.).
to 50°C.
IEC 1010-1, EN 61010-1: Safety requirements for electrical equipment for
IP65 Enclosure rating (Face only), IEC 529
Type 4X Enclosure Rating (Face only), UL50
COUNTER
MODE
cnt ud
rtE cnt
QUAd1
QUAd2
QUAd4
Add Add
Add Sub
dUAL cnt
measurement, control, and laboratory use, Part 1.
RATE
ENABLED
10 KHz
7.5 KHz
5 KHz
5 KHz
2.5 KHz
7.5 KHz
7.5 KHz
7.5 KHz
RATE
DISABLED
20 KHz
20 KHz
10 KHz
8 KHz
5 KHz
10 KHz
10 KHz
10 KHz
EN 61000-4-2 Level 2; 4 Kv contact
EN 61000-4-3 Level 3; 10 V/m
EN 61000-4-4 Level 4; 2 Kv I/O
EN 61000-4-6 Level 3; 10 V/rms
ENV 50204
EN 55011
Level 3; 8 Kv air
80 MHz - 1 GHz
Level 3; 2 Kv power
150 KHz - 80 MHz
Level 3; 10 V/m
900 MHz ± 5 MHz
200 Hz, 50% duty cycle
Enclosure class A
Power mains class A
1
2
Counter
Factor. The unit’s counter (internal count value) keeps track of the scaled input
pulse count which results in the desired reading value for the count display.
Input A accepts the signal for the count and Input B is used for quadrature, dual
counter, anti-coincidence counting, or up/down control counting.
to the unit, the contents of the counter are saved. This allows counting over
consecutive shifts, days, etc. The total count can accumulate to 99,999,999.
The “B” counter, if enabled, can accumulate 9,999,999 counts.
Note: The counter value will roll over and flash “tot OVEr” when the count
Rate
method (1/tau) to calculate the rate value. The unit counts on the negative edge
of the input pulses. After the programmed minimum update time elapses and
the next negative edge occurs, the unit counts the number of edges that occurred
during the elapsed time. The number of edges is multiplied by the rate scaling
value to calculate the rate value. At slower rates, averaging can be
accomplished by programming the rate minimum update time for the desired
response. Extensive scaling capabilities allow practically any desired reading
at very slow count rates.
DISPLAY SELECTION
common. The display indicates either:
select button. If display scroll is enabled, the display will toggle automatically
approximately every four seconds between the rate and count values. If both
the select button and display scroll are enabled, pressing and holding the select
button pauses the automatic toggle (if enabled) as long as the select button is
held.
The CUB5 receives incoming pulses and multiplies them by the Count Scale
The count(s) reset to zero when a manual reset is performed. At loss of power
value exceeds 99,999,999, indicating an overflow condition. The “B”
counter, if enabled, will roll over and flash “btot OVEr” when the count
exceeds 9,999,999.
The signal at Input A is for the Rate indicator, which uses a time interval
In the normal operating mode the program terminal is not connected to
If the Select button is enabled, the display may be toggled by pressing the
Rate value designated by an “R” to the left of the display,
“A” count value (no designator), or
“B” count value designated by a “b” to the left of the display
BLOCK DIAGRAM