CUB50000 Red Lion Controls, CUB50000 Datasheet - Page 4

COUNTER/RATE INDICATOR RELFECT

CUB50000

Manufacturer Part Number
CUB50000
Description
COUNTER/RATE INDICATOR RELFECT
Manufacturer
Red Lion Controls
Series
CUB5r
Datasheet

Specifications of CUB50000

Count Rate
20kHz
Number Of Digits/alpha
8
Input Type
Voltage
Voltage - Supply
9 V ~ 28 V
Display Type
LCD Non-Backlit
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Output Type
-
Other names
Q517088
RLC500
7. COUNTER B SCALE FACTOR
not change the existing internal count, and only affects the incoming pulse
count. The Count Scale Factor Value can range from 0.0001 to 99.9999.
Note: The precision of a counter application cannot be improved by using a
8. RATE ENABLE (rAtE Enb)
rate programming steps will not appear. This affects the rate only.
9. RATE DECIMAL POINT (rAtE dP)
the count display.
10. RATE DISPLAY(rAtE dSP)
rate input (rate INP) value. The rate display value can be programmed from
000001 to 999999.
11. RATE INPUT(rAtE INP)
dSP) value. The rate input value can be programmed from 00000.1 to 99999.9
and should correspond to the signal input frequency.
12. MINIMUM UPDATE TIME (Lo-Udt)
display. This affects the rate display only. The low update time ranges from 00.1
to 99.9 seconds. To assist in stabilizing an erratic display, increase Lo-Udt for a
display averaging effect.
13. MAXIMUM UPDATE TIME (Hi-Udt)
rate display goes to zero if the time between successive pulses exceeds the high
update (Hi-Udt) time. The high update time ranges from 00.1 to 99.9 seconds.
14. DISPLAY SCROLL (dSPScroL)
and count displays by selecting “YES”. The display time for each display is
fixed and is approximately four seconds per display.
15. USER INPUT (USEr INP)
The function of the User Input can be programmed for one of the following.
Reset (rESEt) - A low level resets the count(s) to zero and as long as the input
Store/Reset (Stor-rSt) - A low level freezes the display. The internal count(s)
Store (StorE) - A low level freezes the display and the unit continues to
Inhibit (INHIbIt) - A low level “freezes” the display and the input signal is
Select Display (dSPSEL) - A low level toggles between the rate display and
16. USER INPUT ASSIGNMENT (USEr ASg) -
be assigned to:
The scale factor is a prescaler, therefore changing the scale factor value does
scale factor greater than one. To accomplish greater precision, more pulse
information must be generated per measuring unit.
Selecting “YES” enables the rate indicator function. If disabled (NO), the
Select the desired decimal point position for the rate display, independent of
Program the desired rate display value which corresponds to the programmed
Program the rate input value that should correspond to the rate display (rate
This is the minimum amount of time between display updates for the rate
This is the maximum amount of time before the rate display goes to zero. The
The unit can be programmed to automatically toggle between the rate display
The User Input is activated when the user terminal is connected to common.
is low, the unit will not process the input signal.
are reset to zero and the unit accumulates counts even when the user input is
held low. The count value(s) update when the user input goes high.
accumulate counts. The count value(s) update when the user input goes high.
ignored.
count display(s).
If the CUB5 is programmed for the “dUAL cnt” mode, the User Input may
(b SCLFAC) INP A-b = dUAL cnt
(INP A-b is “dUAL cnt” and USEr INP not “dSPSEL”)
0
0.0
0.00
0.000
0.0000
0.00000
- (totAL) “A” Counter
- (b totAL) “B” Counter
- (both) “A” and “B” Counters
4
17. FACTORY SETTINGS (FACt SEt)
selected and the front panel select button is pressed. The CUB5 displays
“LOAd” for several seconds and then returns to programming of INP A-b
(Count Mode) parameter. Factory settings for all the programmable values are
listed below.
SCALING FOR COUNT INDICATION
display for each pulse that is input to the unit. In many applications, there will
not be a one-to-one correspondence between input pulses and display units.
Therefore, it is necessary for the CUB5 to scale or multiply the input pulses by
a scaling factor to achieve the desired display units (feet, meters, gallons, etc.)
in the internal count register which results in the desired count display value.
The scale factor is a prescaler, which means changing the scale factor does not
change the existing internal count, but only effects the incoming pulse count.
important to note that the precision of a counter application cannot be improved
by using a scale factor greater than one. To accomplish greater precision, more
pulse information must be generated per measuring unit. The following formula
is used to calculate the scale factor.
WHERE:
Desired Display Units: Count display units acquired after pulses that occurred.
Decimal Point Position:
EXAMPLE: The counter display is used to indicate the total number of feet
hundredth resolution.
Number of Pulses: Number of pulses required to achieve the desired
All of the parameters are restored to the factory default settings when YES is
The CUB5’s scale factor is factory set to 1, to provide one count on the
The incoming pulses are multiplied by the count scale factor value and stored
The Count Scale Factor Value can range from 0.0001 to 99.9999. It is
Scale Factor = Desired Display Units x Decimal Point Position
0
0.0
0.00
0.000
0.0000
0.00000
used in a process. It is necessary to know the number of pulses for the desired
units to be displayed. The decimal point is selected to show the resolution in
hundredths.
Scale Factor = Desired Display Units x Decimal Point Position
Given that 128 pulses are equal to 1 foot, display total feet with a one-
Scale Factor = 1.00 x 100
Scale Factor = 0.007812 x 100
Scale Factor = 0.7812
INP A-b
dSPSEL
rSt Enb
tot dP
SCLFAC
rAtE Enb
rAtE dP
rAtE dSP
rAtE INP
Lo-Udt
Hi-Udt
dSPScrol
USEr INP
=
=
=
=
=
=
128
Number of Pulses
Number of Pulses
1
10
100
1000
10000
100000
display units.
cnt ud
YES
YES
0
01.0000
YES
001000
01000.0
01.0
01.0
No
rESET
0